Additional equipment that are considered to be energy consumers can be specified using the keyword TABULAR. This is given that a form of reservoir rates (oil/gas production) can be linked to either fuel or power consumption.

This is considered to be a consumer energy function for pure barycentric interpolation, no extrapolation outside convex area. One column defines the function value, the rest of the columns defines the variables for a 1D (if one variable column) or multidimensional interpolation.

Header and unit requirements

HeaderUnitComment
PowerMWFor power driven consumers
FuelSm3/dayFor fuel (turbine) driven consumers

Variable headers can be chosen freely as long as these correspond to the defined variables for the function.

Example

1D tabular energy function

Contents of the file energyfunc_1d_rate_fuel.csv:

RATE,     FUEL
0, 0
1, 137750
1000000, 137750
2000000, 145579
3000000, 153335
4000000, 161022
5000000, 168644

The entry in FACILITY_INPUTS:

FACILITY_INPUTS:
- NAME: gasinjectiondata
FILE: energyfunc_1d_rate_fuel.csv
TYPE: TABULAR

The entry in INSTALLATIONS under a fuel consumer:

INSTALLATIONS:
....
- NAME: gasinjection
CATEGORY: COMPRESSOR
ENERGY_USAGE_MODEL:
TYPE: TABULATED
ENERGYFUNCTION: gasinjectiondata
VARIABLES:
- NAME: RATE
EXPRESSION: SIM1;GAS_INJ # [Sm3/day]
Note

Note that the name RATE in the input file (under FACILITY_INPUT) and the variable name RATE under VARIABLES must be equal!

3D tabular energy function

Contents of file energyfunc_3d_rate_ps_pd_power.csv:

     RATE, SUCTION_PRESSURE, DISCHARGE_PRESSURE,       POWER
# [Sm3/d], [bar], [bar], [MW]
1.00E+06, 10, 12.72, 0.3664
1.00E+06, 10, 26.21, 2.293
1.00E+06, 26, 31.36, 0.2739
1.00E+06, 26, 70.77, 6.28
1.00E+06, 34, 41.21, 0.368
1.00E+06, 34, 94.24, 8.435
1.00E+06, 78, 94.12, 0.7401
1.00E+06, 78, 231.6, 22.46
6.00E+06, 26, 36.93, 4.197
6.00E+06, 26, 57.43, 7.32
6.00E+06, 38, 46.96, 2.156
6.00E+06, 38, 106.2, 9.557
6.00E+06, 54, 67.26, 1.95
6.00E+06, 54, 155.6, 14.35
6.00E+06, 78, 94.17, 1.399
6.00E+06, 78, 231.6, 22.46
1.10E+07, 42, 66.92, 9.712
1.10E+07, 42, 81.63, 11.89
1.10E+07, 62, 75.64, 3.678
1.10E+07, 62, 180.8, 16.94
1.10E+07, 78, 97.79, 3.452
1.10E+07, 78, 231.6, 22.46

The entry in FACILITY_INPUTS:

FACILITY_INPUTS:
- NAME: booster
FILE: energyfunc_3d_rate_ps_pd_power.csv
TYPE: TABULAR

The entry in INSTALLATIONS under a fuel consumer (for 3-d tabular):

INSTALLATIONS:
...
- NAME: gasexport
CATEGORY: COMPRESSOR
ENERGY_USAGE_MODEL:
TYPE: TABULATED
ENERGYFUNCTION: booster
VARIABLES:
- NAME: RATE
EXPRESSION: SIM1;GAS_SALES # [Sm3/day]
- NAME: SUCTION_PRESSURE
EXPRESSION: SIM1;SUCTION_PRESSURE {+} 3 # [bara]
- NAME: DISCHARGE_PRESSURE
EXPRESSION: 100 # [bara]