Description

HEAD is a keyword that is used defining PUMP and COMPRESSOR CHARTS. Head can either be given as a M, KJ_PER_KG, JOULE_PER_KG.

For compressors, it is used in two separate ways under the MODELS or section:

  • Defining the UNITS of HEAD
  • Defining the set of values for HEAD under CURVES section. Here, this must be given as a set of values whose length (number of variables) match the correlating EFFICIENCY and RATE values.

For pumps, it is defined under the FACILITY_INPUTS section.

Format

COMPRESSORS

MODELS:
- NAME: <name of chart, for reference>
...
UNITS:
HEAD: <polytropic head unit, M, KJ_PER_KG, JOULE_PER_KG supported>
...
....

PUMPS

FACILITY_INPUTS:
- NAME: <pump chart name>
...
UNITS:
HEAD: <polytropic head unit, M, KJ_PER_KG, JOULE_PER_KG supported>
...

Example

COMPRESSORS

MODELS:
- NAME: predefined_variable_speed_compressor_chart
TYPE: COMPRESSOR_CHART
CHART_TYPE: VARIABLE_SPEED
UNITS:
RATE: AM3_PER_HOUR
HEAD: M
EFFICIENCY: FRACTION
CURVES:
- SPEED: 7500
RATE: [2900, 3503, 4002, 4595.0]
HEAD: [8412.9, 7996, 7363, 6127]
EFFICIENCY: [0.72, 0.75, 0.74, 0.70]