HEAD_MARGIN
Description
When calibrating pump charts to historical data, the head values at maximum speed could be put in the cloud of data to be unbiased. However, eCalc will treat all head values above the maximum defined area in the chart infeasible (i.e., outside pump capacity). To mitigate this when running through historical data for power calibration, one can adjust the head margin with this keyword.
Calculated head values above maximum head values from the chart will be set equal to maximum head values before power calculations if they are within the margin given. Calculated head values larger than maximum + margin will still be infeasible.
Format
The head margin can be specified in mlc
(meter liquid column):
HEAD_MARGIN: <margin>
Example
NAME: pump_name
TYPE: PUMP_CHART_SINGLE_SPEED
UNITS:
HEAD: M
RATE: AM3_PER_HOUR
EFFICIENCY: PERCENTAGE
FILE: <path_to_chart_file>.csv
HEAD_MARGIN: 10.0