LOWER_HEATING_VALUE
Description
LOWER_HEATING_VALUE
is a required to be specified under the TURBINE_MODEL keyword.
This must be specified in MJ/Sm3
This can only be inputted as a single value and dictates the quantity of thermal energy available after burning a standard cubic metre of fuel (natural gas in this gas).
Format
MODELS:
- NAME: <name of turbine>
TYPE: TURBINE
...
LOWER_HEATING_VALUE: <lower heating value in MJ/Sm3>
Example
MODELS:
- NAME: compressor_train_turbine
TYPE: TURBINE
LOWER_HEATING_VALUE: 38 # MJ/Sm3
TURBINE_LOADS: [0, 2.352, 4.589, 6.853, 9.125, 11.399, 13.673, 15.947, 18.223, 20.496, 22.767] # MW
TURBINE_EFFICIENCIES: [0, 0.138, 0.210, 0.255, 0.286, 0.310, 0.328, 0.342, 0.353, 0.360, 0.362]
POWER_ADJUSTMENT_CONSTANT: 10