MAXIMUM_DISCHARGE_PRESSURE
MODELS / MAXIMUM_DISCHARGE_PRESSURE
Description
MAXIMUM_DISCHARGE_PRESSURE
sets the highest possible discharge pressure that a compressor can deliver.
In reality, setting the maximum discharge pressure can be to avoid excessively high pressures which can be a safety concern on an installation.
Functionality
This is an optional setting and is only supported for SINGLE SPEED COMPRESSORS, and only if the PRESSURE_CONTROL
is DOWNSTREAM_CHOKE
.
- If
MAXIMUM_DISCHARGE_PRESSURE
has been defined and if any of the inputted discharge pressures exceeds the maximum value, a ValueError message will be raised. - If any of the input rates and suction pressures result in a discharge pressure which is above the
MAXIMUM_DISCHARGE_PRESSURE
, the suction pressure will be reduced until the calculations provide a discharge pressure below the maximum value (assuming an upstream choke can handle this). - The outlet stream will then be further choked from the
MAXIMUM_DISCHARGE_PRESSURE
to the target discharge pressure using theDOWNSTREAM_CHOKE
pressure control.
Format
MODELS:
- NAME: <model name>
TYPE: SINGLE_SPEED_COMPRESSOR_TRAIN
FLUID_MODEL: <reference to fluid model>
PRESSURE_CONTROL: <DOWNSTREAM_CHOKE>
MAXIMUM_DISCHARGE_PRESSURE: <Maximum discharge pressure in bar>
COMPRESSOR_TRAIN:
STAGES:
- INLET_TEMPERATURE: <inlet temperature in Celsius for stage>
COMPRESSOR_CHART: <reference to compressor chart model>
...