Skip to main content

POWER_ADJUSTMENT_FACTOR

MODELS / POWER_ADJUSTMENT_FACTOR

Description

Optional factor adjusting the power in the model. The power is multiplied by this factor. Can be used in combination with POWER_ADJUSTMENT_CONSTANT.

Format

MODELS:
- NAME: <model name>
TYPE: <model type>
...
POWER_ADJUSTMENT_FACTOR: <value>

Example

MODELS:
- NAME: simple_compressor
TYPE: SIMPLIFIED_VARIABLE_SPEED_COMPRESSOR_TRAIN
...
POWER_ADJUSTMENT_FACTOR: 1.2
MODELS:
- NAME: simple_compressor
TYPE: SIMPLIFIED_VARIABLE_SPEED_COMPRESSOR_TRAIN
...
POWER_ADJUSTMENT_CONSTANT: 10 #MW
POWER_ADJUSTMENT_FACTOR: 1.2