RATE
INSTALLATIONS / [...] / ENERGY_USAGE_MODEL / RATE
Description
This can be used in three ways:
- Used to define the rate for some ENERGY_USAGE_MODEL
types using an
Expression
- Used defining the units of a PUMP and COMPRESSOR CHARTS.
- From eCalc v8.8: Used to define the rate for EMISSION in VENTING_EMITTERS
Format
RATE: <rate expression>
- NAME: <model name>
TYPE: <pump or compressor type>
...
UNITS:
RATE: <AM3_PER_HOUR>
...
Example
RATE: SIM1:GAS_PROD
- NAME: pump
TYPE: PUMP_CHART_VARIABLE_SPEED
...
UNITS:
RATE: <AM3_PER_HOUR>
...
Use in EMISSIONS for VENTING_EMITTERS (from eCalc v8.8)
The keywords VALUE
and CATEGORY are required, while UNIT and TYPE are optional.
For venting emitters of TYPE
DIRECT_EMISSION
(from eCalc v8.13):
Allowed values for UNIT
are KG_PER_DAY and TONS_PER_DAY, while STREAM_DAY and CALENDAR_DAY are valid for TYPE
.
For venting emitters of TYPE
OIL_VOLUME
(from eCalc v8.13):
Only allowed value for UNIT
is SM3_PER_DAY
Example with venting emitter of TYPE
DIRECT_EMISSION
:
Format
VENTING_EMITTERS:
- NAME: <emitter name>
CATEGORY: <category>
TYPE: <emission type>
EMISSIONS:
- NAME: <emission name>
RATE:
VALUE: <emission rate>
UNIT: <emission rate unit, default KG_PER_DAY>
TYPE: <emission rate type, default STREAM_DAY>
Example
VENTING_EMITTERS:
- NAME: SomeVentingEmitter
CATEGORY: COLD-VENTING-FUGITIVE
TYPE: DIRECT_EMISSION
EMISSIONS:
- NAME: CH4
RATE:
VALUE: 4
UNIT: KG_PER_DAY
TYPE: STREAM_DAY