Skip to main content

RATE

INSTALLATIONS / [...] / ENERGY_USAGE_MODEL / RATE

Description

This can be used in three ways:

Format

RATE: <rate expression>
    - NAME: <model name>
TYPE: <pump or compressor type>
...
UNITS:
RATE: <AM3_PER_HOUR>
...

Example

RATE: SIM1:GAS_PROD
    - NAME: pump
TYPE: PUMP_CHART_VARIABLE_SPEED
...
UNITS:
RATE: <AM3_PER_HOUR>
...

Use in EMISSIONS for VENTING_EMITTERS (from eCalc v8.8)

The keywords VALUE and CATEGORY are required, while UNIT and TYPE are optional.

For venting emitters of TYPE DIRECT_EMISSION (from eCalc v8.13): Allowed values for UNIT are KG_PER_DAY and TONS_PER_DAY, while STREAM_DAY and CALENDAR_DAY are valid for TYPE.

For venting emitters of TYPE OIL_VOLUME (from eCalc v8.13): Only allowed value for UNIT is SM3_PER_DAY

Example with venting emitter of TYPE DIRECT_EMISSION:

Format

VENTING_EMITTERS:
- NAME: <emitter name>
CATEGORY: <category>
TYPE: <emission type>
EMISSIONS:
- NAME: <emission name>
RATE:
VALUE: <emission rate>
UNIT: <emission rate unit, default KG_PER_DAY>
TYPE: <emission rate type, default STREAM_DAY>

Example

VENTING_EMITTERS:
- NAME: SomeVentingEmitter
CATEGORY: COLD-VENTING-FUGITIVE
TYPE: DIRECT_EMISSION
EMISSIONS:
- NAME: CH4
RATE:
VALUE: 4
UNIT: KG_PER_DAY
TYPE: STREAM_DAY