VENTING_EMITTERS
New definition of VENTING_EMITTERS from eCalc v8.13!
INSTALLATIONS / VENTING_EMITTERS
Required | Child of | Children/Options |
---|---|---|
Yes | INSTALLATIONS | NAME EMISSION_NAME CATEGORY EMITTER_MODEL EMISSIONS VOLUME |
- eCalc version 9.17: the optional keyword CONDITION and CONDITIONS can be used to define conditions that affect the
RATE
. - eCalc version 8.13: Updated definition of
VENTING_EMITTERS
. New mandatory keyword TYPE is defining the venting emitter type. Based on the selected type, the new keywords EMISSIONS (TYPE
:DIRECT_EMISSION
) or VOLUME (TYPE
:OIL_VOLUME
) should be specified. - eCalc version 8.8: Updated definition of
VENTING_EMITTERS
. New keyword EMISSION is replacing EMITTER_MODEL and EMISSION_NAME. Now possible to defineUNIT
andTYPE
for emission rate. - eCalc version 8.7: VENTING_EMITTERS keyword is replacing the DIRECT_EMITTERS keyword.
- eCalc version 8.6 and earlier: Use
DIRECT_EMITTERS
as before.
eCalc version 8.7 and before: Description
The VENTING_EMITTERS keyword covers the direct emissions on the installation that are not consuming energy. The attributes NAME, EMISSION_NAME, CATEGORY and EMITTER_MODEL are required.
Format
VENTING_EMITTERS:
- NAME: <emitter name>
EMISSION_NAME: <emission name>
CATEGORY: <category>
EMITTER_MODEL: <emitter model>
Example
VENTING_EMITTERS:
- NAME: SomeVentingEmitter
EMISSION_NAME: CH4
CATEGORY: COLD-VENTING-FUGITIVE
EMITTER_MODEL:
<emitter model data>
...
- NAME: SomeOtherVentingEmitter
EMISSION_NAME: C2H6
CATEGORY: COLD-VENTING-FUGITIVE
EMITTER_MODEL:
<emitter model data>
eCalc from version 8.8: Description
The attributes NAME, CATEGORY and EMISSION are required.
Format
VENTING_EMITTERS:
- NAME: <emitter name>
CATEGORY: <category>
EMISSION:
<emission data>
Example
VENTING_EMITTERS:
- NAME: SomeVentingEmitter
CATEGORY: COLD-VENTING-FUGITIVE
EMISSION:
<emission data>
...
- NAME: SomeOtherVentingEmitter
CATEGORY: COLD-VENTING-FUGITIVE
EMISSION:
<emission data>
eCalc from version 8.13: Description
The keywords NAME, CATEGORY and TYPE are required. The venting emitter type can be either DIRECT_EMISSION
or OIL_VOLUME
.
The keywords EMISSIONS or VOLUME are required, dependent on which venting emitter type is used.
Venting emitter of TYPE DIRECT_EMISSION
: Specify emission rates directly.
Format
VENTING_EMITTERS:
- NAME: <emitter name>
CATEGORY: <category>
TYPE: DIRECT_EMISSION
EMISSIONS:
<emission data>
Example
VENTING_EMITTERS:
- NAME: SomeVentingEmitter
CATEGORY: COLD-VENTING-FUGITIVE
TYPE: DIRECT_EMISSION
EMISSIONS:
- NAME: co2
RATE:
VALUE: 4
UNIT: KG_PER_DAY
TYPE: STREAM_DAY
- NAME: ch4
RATE:
VALUE: 2
UNIT: KG_PER_DAY
TYPE: STREAM_DAY
Venting emitter of TYPE OIL_VOLUME
: Specify oil loading/storage volumes, and emission factors - to calculate emissions as fractions of the volume.
Format
VENTING_EMITTERS:
- NAME: <emitter name>
CATEGORY: <category>
TYPE: OIL_VOLUME
VOLUME:
<oil volumes/rates and emission factors>
Example
VENTING_EMITTERS:
- NAME: SomeVentingEmitter
CATEGORY: COLD-VENTING-FUGITIVE
TYPE: OIL_VOLUME
VOLUME:
RATE:
VALUE: 10
UNIT: SM3_PER_DAY
TYPE: STREAM_DAY
EMISSIONS:
- NAME: co2
EMISSION_FACTOR: 0.04
- NAME: ch4
EMISSION_FACTOR: 0.02
eCalc from version 9.17: Description
The keywords NAME, CATEGORY and TYPE are required. The venting emitter type can be either DIRECT_EMISSION
or OIL_VOLUME
.
The keywords EMISSIONS or VOLUME are required, dependent on which venting emitter type is used.
New Feature: CONDITION and CONDITIONS From eCalc version 9.17, the optional keyword CONDITION(S) can be used to define conditions that affect the RATE. This allows for more precise modeling of scenarios, such as when an asset is producing or not, by using time series or logical expressions.
- Usage:
CONDITION(S)
can be applied under RATE for both DIRECT_EMISSION and OIL_VOLUME types. - Example: A condition can specify that emissions only occur when a time series value equals 1.
Format (TYPE: DIRECT_EMISSION)
VENTING_EMITTERS:
- NAME: <emitter name>
CATEGORY: <category>
TYPE: DIRECT_EMISSION
EMISSIONS:
- NAME: <emission name>
RATE:
VALUE: <rate value>
UNIT: <rate unit>
TYPE: <rate type>
CONDITIONS:
- <condition expression>
Example (TYPE: DIRECT_EMISSION)
VENTING_EMITTERS:
- NAME: SomeVentingEmitter
CATEGORY: COLD-VENTING-FUGITIVE
TYPE: DIRECT_EMISSION
EMISSIONS:
- NAME: co2
RATE:
VALUE: 4
UNIT: KG_PER_DAY
TYPE: STREAM_DAY
CONDITION: DRILLING;PRODUCTION_DAYS == 1
- NAME: ch4
RATE:
VALUE: 2
UNIT: KG_PER_DAY
TYPE: STREAM_DAY
CONDITIONS:
- DRILLING;PRODUCTION_DAYS == 1
- <Some other condition>
Format (TYPE: OIL_VOLUME)
VENTING_EMITTERS:
- NAME: <emitter name>
CATEGORY: <category>
TYPE: OIL_VOLUME
VOLUME:
RATE:
VALUE: <rate value>
UNIT: <rate unit>
TYPE: <rate type>
CONDITION: <condition expression>
EMISSIONS:
- NAME: <emission name>
EMISSION_FACTOR: <emission factor>
...
Example (TYPE: OIL_VOLUME)
VENTING_EMITTERS:
- NAME: SomeVentingEmitter
CATEGORY: COLD-VENTING-FUGITIVE
TYPE: OIL_VOLUME
VOLUME:
RATE:
VALUE: 10
UNIT: SM3_PER_DAY
TYPE: STREAM_DAY
CONDITION: DRILLING;PRODUCTION_DAYS == 1
EMISSIONS:
- NAME: co2
EMISSION_FACTOR: 0.04
- NAME: ch4
EMISSION_FACTOR: 0.02