VOLUME

New keyword from eCalc v8.13!


VENTING_EMITTERS / VOLUME

Description

From eCalc 8.13: Used to define oil volume/rates and emission factors for venting emitters of TYPE OIL_VOLUME

The keywords RATE and EMISSIONS are required.

Format

VOLUME:
RATE:
VALUE: <oil volume/rate>
UNIT: <oil volume/rate unit>
TYPE: <oil volume/rate type, default STREAM_DAY>
EMISSIONS:
- NAME: <emission name>
EMISSION_FACTOR: <volume to emission factor, fraction of oil volume>
...

Example

    VOLUME:
RATE:
VALUE: 10
UNIT: SM3_PER_DAY
TYPE: STREAM_DAY
EMISSIONS:
- NAME: co2
EMISSION_FACTOR: 0.04
- NAME: ch4
EMISSION_FACTOR: 0.02