eCalc v13.8
Changes in results?
✔️ YES: Stream mixing now preserves total enthalpy, giving physically correct outlet temperatures. This may change results for models using stream mixing.
Bug Fixes
- Fuel must now be defined for the full operational period of a consumer or generator set. Previously, missing fuel definitions for certain periods could silently produce incorrect results. eCalc will now raise a validation error if the fuel definition does not cover the full period. If you encounter this error after upgrading, ensure that your fuel definitions span the required time range.
- Fixed fuel model not covering the full simulation time range — fuel values could be missing for timesteps outside the fuel definition's own time series.