eCalc v7.1
Features
-
Add new CATEGORY with name OFFSHORE-WIND to report power usage from offshore windfarms. Should be negative load to deduct from genset, if what is supplied externally. Also added to
LTP Reporting
. See excerpt example below:- NAME: wind_turbine
CATEGORY: OFFSHORE-WIND
ENERGY_USAGE_MODEL:
TYPE: DIRECT
LOAD: -4.4 # MW -
Add new CATEGORY with name TURBINE-GENERATOR and POWER-FROM-SHORE to report power consumption separately from installation and onshore (land) for generators. If not set, defaults to TURBINE-GENERATOR. See excerpt example below:
GENERATORSETS:
- NAME: genset
CATEGORY: TURBINE-GENERATOR
ELECTRICITY2FUEL: A_genset
...
...
- NAME: power_from_shore
CATEGORY: POWER-FROM-SHORE
ELECTRICITY2FUEL: onshore_power
...
where electricity2fuel for onshore power in general would have power map to 0 fuel usage
-
Add new CATEGORY with name GAS-DRIVEN-COMPRESSOR to report power consumption for gas(-turbine)-driven compressors for LTP. Also added to
LTP Reporting
. See excerpt example below:- NAME: gascompression_2
CATEGORY: GAS-DRIVEN-COMPRESSOR
ENERGY_USAGE_MODEL:
TYPE: COMPRESSOR -
Allow single speed and variable speed compressor train to run with zero pressure and non-zero rate. Will raise warning, and affected time steps will not be calculated, but eCalc will run.
-
Add a POWER column data to the COMPRESSOR_TABULAR csv-file for a fuel-driven SAMPLED_COMPRESSOR in order to also get energy reported as power (MW). See
Header requirements for the sampled compressor csv file
-
Add surge control margin to variable speed compressor charts. See
Surge control margin for variable speed compressor chart
. -
Ensure non-infinite loops by setting max 50 iterations for compressor models. Will raise warning in the logger if not converged.
-
Bug in max rate calculation for simplified compressor train. Wrong convergence criterion leading to too early exit from iteration.
-
VARIABLES can be specified in yaml and referred to in expressions.
VARIABLES:
salt_water_injection:
VALUE: SIM1:COL1 {*} 2Use this variable by referencing it as
$var.salt_water_injection
in an expression.EXPRESSION: "$var.salt_water_injection {/} 2"
See VARIABLES for more information.
Breaking changes
- CONVERT_TO_RATE no longer supported. If this was something you used, let us know so we can know the use case.
CLI