Electrical Engineering Package — Architecture Proposal

1. Motivation

NeqSim already models mechanical design for process equipment (wall thickness, materials, weights, cost) via the MechanicalDesign class hierarchy. However, every piece of process equipment also has an electrical scope: motors, variable-speed drives, starters, cabling, switchgear, transformers, protection, hazardous area classification, and lighting/heat tracing.

Currently NeqSim tracks power only as a scalar mechanical shaft power (kW). There is no concept of:

Adding an ElectricalDesign layer — parallel to MechanicalDesign — enables NeqSim to produce equipment load lists, motor data sheets, one-line diagram data, cable schedules, and electrical cost estimates.


2. Design Principles

Principle How
Mirror the MechanicalDesign pattern ElectricalDesign base class per equipment, plugged in via getElectricalDesign() / initElectricalDesign()
Separation of concerns Equipment classes stay focused on process; electrical scope is a separate object
Data-driven Standards data (IEC motor frames, cable ampacity tables) loaded from CSV resources
Composable ElectricalDesign owns child objects (Motor, VFD, Cables, Starter) that are independently testable
JSON-reportable Every class implements toJson() for integration with report generators
Java 8 compatible No var, List.of, records, etc.

3. Package Structure

src/main/java/neqsim/process/
├── electricaldesign/                         ← NEW top-level package
│   ├── ElectricalDesign.java                 ← Base class (mirrors MechanicalDesign)
│   ├── ElectricalDesignResponse.java         ← JSON serialization helper
│   │
│   ├── components/                           ← Reusable electrical component models
│   │   ├── ElectricalMotor.java              ← Motor model (IEC/NEMA sizing)
│   │   ├── VariableFrequencyDrive.java       ← VFD model
│   │   ├── SoftStarter.java                  ← Soft-starter model
│   │   ├── DirectOnLineStarter.java          ← DOL starter
│   │   ├── ElectricalCable.java              ← Cable sizing model
│   │   ├── Transformer.java                  ← Transformer model
│   │   ├── Switchgear.java                   ← Switchgear / MCC bucket
│   │   ├── UninterruptiblePowerSupply.java   ← UPS model
│   │   ├── ElectricalHeatTracing.java        ← Heat tracing for pipes/vessels
│   │   └── HazardousAreaClassification.java  ← ATEX/IECEx zone classification
│   │
│   ├── loadanalysis/                         ← System-level analysis
│   │   ├── ElectricalLoadList.java           ← Aggregated load list
│   │   ├── LoadItem.java                     ← Single load entry
│   │   ├── LoadDiversityCalculator.java      ← Diversity & demand factors
│   │   └── PowerBalanceReport.java           ← Power balance / load flow summary
│   │
│   ├── standards/                            ← Electrical standards data
│   │   ├── IEC60034Standard.java             ← Motor efficiency classes (IE1-IE4)
│   │   ├── IEC60502Standard.java             ← Cable sizing tables
│   │   ├── IEC61439Standard.java             ← Switchgear standards
│   │   ├── IEEE841Standard.java              ← Petroleum/chemical industry motors
│   │   ├── NEMAMotorStandard.java            ← NEMA motor frame/sizing
│   │   └── ATEXClassification.java           ← ATEX/IECEx zone mapping
│   │
│   ├── data/                                 ← Data source abstractions
│   │   ├── ElectricalDesignDataSource.java   ← Interface for data loading
│   │   └── DatabaseElectricalDesignDataSource.java  ← CSV/H2 data loader
│   │
│   ├── compressor/                           ← Equipment-specific electrical designs
│   │   └── CompressorElectricalDesign.java
│   ├── pump/
│   │   └── PumpElectricalDesign.java
│   ├── heatexchanger/
│   │   └── HeatExchangerElectricalDesign.java
│   ├── separator/
│   │   └── SeparatorElectricalDesign.java
│   ├── pipeline/
│   │   └── PipelineElectricalDesign.java     ← Heat tracing, cathodic protection
│   └── system/
│       └── SystemElectricalDesign.java       ← Plant-wide aggregation
│
├── equipment/                                ← EXISTING (modified)
│   ├── ProcessEquipmentInterface.java        ← Add getElectricalDesign(), initElectricalDesign()
│   └── ProcessEquipmentBaseClass.java        ← Add default implementations
│
└── processmodel/
    └── ProcessSystem.java                    ← Add electrical load aggregation methods

4. Core Classes

4.1 ElectricalDesign (Base Class)

Mirrors MechanicalDesign. Every equipment can have one.

package neqsim.process.electricaldesign;

public class ElectricalDesign implements java.io.Serializable {

    private ProcessEquipmentInterface processEquipment;

    // === Power requirements (derived from process) ===
    private double shaftPowerKW;           // From process equipment getPower()
    private double electricalInputKW;      // Including motor + VFD losses
    private double apparentPowerKVA;       // = electricalInputKW / powerFactor
    private double reactivePowerKVAR;      // = apparentPowerKVA × sin(φ)
    private double powerFactor;            // cos φ (typically 0.85–0.95)

    // === Voltage & frequency ===
    private double ratedVoltageV;          // e.g. 400, 690, 3300, 6600, 11000 V
    private double frequencyHz;            // 50 or 60 Hz
    private int phases;                    // 1 or 3

    // === Electrical components ===
    private ElectricalMotor motor;
    private VariableFrequencyDrive vfd;    // null if DOL or soft-start
    private ElectricalCable powerCable;
    private ElectricalCable controlCable;
    private Switchgear switchgear;
    private HazardousAreaClassification hazArea;

    // === Design margins ===
    private double motorSizingMargin;      // typically 1.10–1.15 (10–15% over shaft power)
    private double cableDeratingFactor;    // ambient temp, grouping, burial derating
    private double diversityFactor;        // for load list contribution (0–1)
    private boolean isContinuousDuty;      // S1 duty vs intermittent

    // === Standards ===
    private String motorStandard;          // "IEC" or "NEMA"
    private String cableStandard;          // "IEC 60502" or "NEC"
    private String hazAreaStandard;        // "IECEx" or "ATEX" or "NEC 500/505"

    // === Core methods ===
    public void calcDesign() { ... }       // Size all electrical components
    public void readDesignSpecifications() { ... }
    public String toJson() { ... }

    // === Derived values ===
    public double getFullLoadCurrentA() { ... }
    public double getStartingCurrentA() { ... }
    public double getCableVoltageDrop() { ... }
    public double getTotalElectricalLossesKW() { ... }
}

4.2 ElectricalMotor

package neqsim.process.electricaldesign.components;

public class ElectricalMotor implements java.io.Serializable {

    // === Nameplate data ===
    private double ratedPowerKW;
    private double ratedVoltageV;
    private double ratedCurrentA;
    private double ratedSpeedRPM;
    private int poles;                      // 2, 4, 6, 8
    private double frequencyHz;
    private double efficiencyPercent;       // At full load
    private double powerFactorFL;          // At full load
    private String efficiencyClass;        // IE1, IE2, IE3, IE4 (IEC 60034-30-1)

    // === Motor sizing ===
    private String frameSize;              // IEC: 71, 80, 90, ..., 450  or NEMA: 143T, 286T, ...
    private String enclosureType;          // TEFC, TENV, ODP, TEAAC, etc.
    private String insulationClass;        // B, F, H
    private String dutyType;              // S1 (continuous), S2, S3, ...
    private double serviceFactor;          // 1.0 (IEC) or 1.15 (NEMA)

    // === Starting characteristics ===
    private double lockedRotorCurrentMultiplier;  // Typically 6–8× FLA
    private String startingMethod;         // DOL, Star-Delta, Soft-Start, VFD
    private double startingTorquePercent;   // % of FLT

    // === Hazardous area ===
    private String exProtection;           // Ex d, Ex e, Ex n, Ex p, Ex ia/ib
    private String temperatureClass;       // T1–T6
    private String gasGroup;              // IIA, IIB, IIC

    // === Weight & cost ===
    private double weightKg;
    private double estimatedCostUSD;

    // === Methods ===
    public void sizeMotor(double shaftPowerKW, double margin, String standard) { ... }
    public double getEfficiencyAtLoad(double loadFraction) { ... }
    public double getPowerFactorAtLoad(double loadFraction) { ... }
    public String toJson() { ... }
}

4.3 VariableFrequencyDrive

package neqsim.process.electricaldesign.components;

public class VariableFrequencyDrive implements java.io.Serializable {

    private double ratedPowerKW;
    private double ratedCurrentA;
    private double inputVoltageV;
    private double outputVoltageV;
    private double maxOutputFrequencyHz;
    private double minOutputFrequencyHz;

    // === VFD characteristics ===
    private double efficiencyPercent;       // Typically 95–98%
    private double inputPowerFactor;       // Near unity with active front end
    private String topologyType;           // "2-level", "3-level", "Multi-level"
    private boolean hasActiveRectifier;    // Active front end (low harmonics)

    // === Harmonics ===
    private double thdCurrentPercent;      // Total Harmonic Distortion
    private boolean requiresInputFilter;   // Harmonic filter needed?
    private String pulseConfiguration;     // 6-pulse, 12-pulse, 18-pulse, AFE

    // === Speed range ===
    private double minSpeedPercent;        // Typically 10–30%
    private double maxSpeedPercent;        // Typically 100–120%
    private boolean hasFieldWeakeningRegion;

    // === Cooling ===
    private double heatDissipationKW;
    private String coolingMethod;          // "Air", "Water", "Oil"

    // === Physical ===
    private double weightKg;
    private double estimatedCostUSD;
    private String enclosureRating;        // IP20, IP21, IP54, IP55

    // === Methods ===
    public void sizeVFD(ElectricalMotor motor) { ... }
    public double getEfficiency(double loadFraction, double speedFraction) { ... }
    public double getElectricalInputKW(double motorInputKW) { ... }
    public double getHarmonicDistortion(int harmonicOrder) { ... }
    public String toJson() { ... }
}

4.4 ElectricalCable

package neqsim.process.electricaldesign.components;

public class ElectricalCable implements java.io.Serializable {

    private double lengthM;
    private double crossSectionMM2;        // Conductor area (e.g. 2.5, 4, 6, ..., 630 mm²)
    private int numberOfCores;             // 3, 3+E, 4
    private String conductorMaterial;      // "Copper" or "Aluminium"
    private String insulationType;         // XLPE, PVC, EPR, MI (mineral insulated)

    // === Ratings ===
    private double ampacityA;              // Derated current carrying capacity
    private double baseAmpacityA;          // Before derating
    private double voltageDropPercent;     // At full load
    private double maxVoltageDropPercent;  // Limit (typically 5% running, 15% starting)

    // === Derating factors ===
    private double ambientTempDeratingFactor;
    private double groupingDeratingFactor;
    private double burialDepthDeratingFactor;
    private double altitudeDeratingFactor;

    // === Protection ===
    private double shortCircuitWithstandKA;  // Cable thermal withstand
    private double shortCircuitDurationS;    // Usually 1 s

    // === Installation ===
    private String installationMethod;     // "Tray", "Conduit", "Direct burial", "Ladder"
    private String routeReference;         // Cable route ID

    // === Methods ===
    public void sizeCable(double loadCurrentA, double voltageV, double lengthM,
                          String installMethod, double ambientTempC) { ... }
    public double calculateVoltageDrop(double currentA, double powerFactor) { ... }
    public String toJson() { ... }
}

4.5 CompressorElectricalDesign (Equipment-Specific Example)

package neqsim.process.electricaldesign.compressor;

public class CompressorElectricalDesign extends ElectricalDesign {

    // === Compressor-specific ===
    private boolean useVFD;                // VSD control required?
    private double speedRangeMin;          // Minimum operating speed (fraction)
    private double speedRangeMax;          // Maximum operating speed (fraction)
    private boolean hasAntiSurgeValve;     // Electrically actuated
    private double antiSurgeValvePowerKW;  // Actuator power

    // === Auxiliary loads ===
    private double lubOilPumpPowerKW;
    private double sealGasPanelPowerKW;
    private double instrumentAirPowerKW;
    private double coolingFanPowerKW;      // If air-cooled aftercooler

    // === Instrumentation ===
    private int vibrationProbeCount;
    private int temperatureSensorCount;
    private double instrumentPowerKW;

    @Override
    public void calcDesign() {
        Compressor comp = (Compressor) getProcessEquipment();
        double shaftPower = comp.getPower("kW");

        // 1. Size motor
        getMotor().sizeMotor(shaftPower, getMotorSizingMargin(), getMotorStandard());

        // 2. Size VFD (if applicable)
        if (useVFD) {
            getVfd().sizeVFD(getMotor());
        }

        // 3. Calculate full electrical input
        double motorInput = shaftPower / (getMotor().getEfficiencyPercent() / 100.0);
        double electricalInput = useVFD
            ? getVfd().getElectricalInputKW(motorInput)
            : motorInput;
        setElectricalInputKW(electricalInput + getTotalAuxiliaryPowerKW());

        // 4. Size cables
        getPowerCable().sizeCable(getFullLoadCurrentA(), getRatedVoltageV(),
            getPowerCable().getLengthM(), "Tray", 40.0);

        // 5. Power factor
        double pf = useVFD ? getVfd().getInputPowerFactor()
                           : getMotor().getPowerFactorFL();
        setPowerFactor(pf);
        setApparentPowerKVA(getElectricalInputKW() / pf);
        setReactivePowerKVAR(getApparentPowerKVA()
            * Math.sin(Math.acos(pf)));
    }

    public double getTotalAuxiliaryPowerKW() {
        return lubOilPumpPowerKW + sealGasPanelPowerKW
             + instrumentAirPowerKW + coolingFanPowerKW
             + instrumentPowerKW + antiSurgeValvePowerKW;
    }
}

5. Integration with ProcessEquipmentInterface

Add two new methods to the equipment interface and base class, exactly mirroring the mechanical design pattern:

// ProcessEquipmentInterface.java — add:
ElectricalDesign getElectricalDesign();
void initElectricalDesign();

// ProcessEquipmentBaseClass.java — add default implementations:
private ElectricalDesign electricalDesign;

@Override
public ElectricalDesign getElectricalDesign() {
    return electricalDesign;
}

@Override
public void initElectricalDesign() {
    electricalDesign = new ElectricalDesign(this);
}

Equipment classes override when they need specialization:

// In Compressor.java:
private CompressorElectricalDesign electricalDesign;

@Override
public void initElectricalDesign() {
    electricalDesign = new CompressorElectricalDesign(this);
}

@Override
public CompressorElectricalDesign getElectricalDesign() {
    return electricalDesign;
}

6. ProcessSystem Integration

6.1 Electrical Load Aggregation

// ProcessSystem.java — add:

public void initAllElectricalDesigns() {
    for (ProcessEquipmentInterface eq : unitOperations) {
        eq.initElectricalDesign();
    }
}

public void runAllElectricalDesigns() {
    for (ProcessEquipmentInterface eq : unitOperations) {
        ElectricalDesign ed = eq.getElectricalDesign();
        if (ed != null) {
            ed.calcDesign();
        }
    }
}

public ElectricalLoadList getElectricalLoadList() {
    ElectricalLoadList loadList = new ElectricalLoadList(getName());
    for (ProcessEquipmentInterface eq : unitOperations) {
        ElectricalDesign ed = eq.getElectricalDesign();
        if (ed != null) {
            loadList.addLoad(new LoadItem(eq.getName(), ed));
        }
    }
    loadList.calculateTotals();
    return loadList;
}

public double getTotalElectricalLoadKW() {
    return getElectricalLoadList().getTotalActiveLoadKW();
}

public double getTotalApparentPowerKVA() {
    return getElectricalLoadList().getTotalApparentPowerKVA();
}

public String getElectricalLoadListJson() {
    return getElectricalLoadList().toJson();
}

6.2 ElectricalLoadList

package neqsim.process.electricaldesign.loadanalysis;

public class ElectricalLoadList implements java.io.Serializable {

    private String systemName;
    private List<LoadItem> loads;

    // === Aggregated results ===
    private double totalConnectedKW;       // Sum of all rated motor powers
    private double totalRunningKW;         // Sum of running loads × load factors
    private double totalStandbyKW;         // Standby equipment
    private double diversifiedLoadKW;      // After diversity factor
    private double totalApparentPowerKVA;  // Considering individual power factors
    private double totalReactivePowerKVAR;
    private double weightedPowerFactor;    // Weighted average cos φ
    private double contingencyPercent;     // Typically 10–20%
    private double futureGrowthPercent;    // Typically 10%

    // === Voltage level breakdown ===
    private Map<String, Double> loadByVoltageLevel;  // e.g. "6.6kV" → 5000 kW

    // === Methods ===
    public void calculateTotals() { ... }
    public String toJson() { ... }         // Full load list as JSON
    public String toCsvReport() { ... }    // Electrical load list in standard format
}

6.3 LoadItem

public class LoadItem implements java.io.Serializable {
    private String tagNumber;
    private String equipmentName;
    private String description;
    private double ratedPowerKW;           // Motor nameplate
    private double absorbedPowerKW;        // Actual shaft power from process
    private double electricalInputKW;      // Including losses
    private double apparentPowerKVA;
    private double reactivePowerKVAR;
    private double powerFactor;
    private double ratedVoltageV;
    private double ratedCurrentA;
    private String startingMethod;         // DOL, VFD, Soft-start
    private double loadFactor;             // Operating / rated (0–1)
    private double diversityFactor;        // 0–1
    private boolean isContinuous;
    private boolean isSpare;
    private String hazardousAreaZone;      // Zone 0, 1, 2 or safe
    private String exProtection;           // Ex d, Ex e, etc.
}

7. Data-Driven Design: CSV Resource Files

Place standard reference data in src/main/resources/electricaldata/:

File Content
iec_motor_frames.csv IEC frame sizes, rated power ranges, weight, dimensions, by pole count
nema_motor_frames.csv NEMA frame sizes, HP ranges
iec60034_efficiency.csv IE1–IE4 minimum efficiency by power and pole count
cable_ampacity_xlpe.csv XLPE cable ampacity by cross-section, installation method, temp
cable_ampacity_pvc.csv PVC cable ampacity
transformer_standard_sizes.csv Standard kVA ratings (100, 160, 250, 315, 400, 500, …)
switchgear_ratings.csv Standard busbar and breaker ratings
hazarea_equipment_zones.csv Default hazardous zone for equipment types
vfd_sizing.csv VFD power/current ratings per frame
cable_derating_temp.csv Temperature derating factors
cable_derating_grouping.csv Grouping derating factors

8. Standards Covered

Standard Scope Used In
IEC 60034-1 Rotating electrical machines — rating and performance ElectricalMotor
IEC 60034-30-1 Efficiency classes IE1–IE4 IEC60034Standard, ElectricalMotor.efficiencyClass
IEEE 841 Motors for petroleum/chemical industry IEEE841Standard, ElectricalMotor
NEMA MG 1 Motors and generators (NEMA frame sizes) NEMAMotorStandard
IEC 60502 Power cables 1–30 kV ElectricalCable
IEC 60364 Low-voltage installations — cable sizing ElectricalCable
IEEE 835 Cable ampacity tables ElectricalCable
IEC 61800 Adjustable speed electrical power drive systems VariableFrequencyDrive
IEEE 519 Harmonic limits VariableFrequencyDrive.thdCurrentPercent
IEC 61439 Low-voltage switchgear assemblies Switchgear
IEC 60076 Power transformers Transformer
IEC 60079 / ATEX Equipment for explosive atmospheres HazardousAreaClassification
API RP 500/505 Hazardous area classification for petroleum facilities HazardousAreaClassification
NORSOK E-001 Electrical systems System-level voltage selection
IEC 61508 / 61511 Functional safety (SIL) ElectricalDesign.silLevel

9. Example Usage

9.1 Single Compressor

// After process simulation
Compressor comp = new Compressor("Export Compressor", feed);
comp.setOutletPressure(120.0);
process.add(comp);
process.run();

// Initialize electrical design
comp.initElectricalDesign();
CompressorElectricalDesign elecDesign = comp.getElectricalDesign();

// Configure
elecDesign.setRatedVoltageV(6600);
elecDesign.setFrequencyHz(50);
elecDesign.setMotorStandard("IEC");
elecDesign.setMotorSizingMargin(1.10);  // 10% margin
elecDesign.setUseVFD(true);
elecDesign.setHazAreaStandard("IECEx");
elecDesign.getPowerCable().setLengthM(150.0);

// Run electrical design
elecDesign.calcDesign();

// Get results
String json = elecDesign.toJson();
System.out.println("Motor: " + elecDesign.getMotor().getRatedPowerKW() + " kW");
System.out.println("FLA: " + elecDesign.getFullLoadCurrentA() + " A");
System.out.println("Cable: " + elecDesign.getPowerCable().getCrossSectionMM2() + " mm²");
System.out.println("VFD THD: " + elecDesign.getVfd().getThdCurrentPercent() + " %");
System.out.println("Total input: " + elecDesign.getElectricalInputKW() + " kW");

9.2 Full Plant Load List

// Build process
ProcessSystem process = new ProcessSystem();
process.add(feed);
process.add(separator);
process.add(compressor1);
process.add(compressor2);
process.add(pump);
process.add(cooler);
process.run();

// Run all electrical designs
process.initAllElectricalDesigns();
process.runAllElectricalDesigns();

// Get plant electrical summary
ElectricalLoadList loadList = process.getElectricalLoadList();
System.out.println("Total connected: " + loadList.getTotalConnectedKW() + " kW");
System.out.println("Total running: " + loadList.getTotalRunningKW() + " kW");
System.out.println("Total apparent: " + loadList.getTotalApparentPowerKVA() + " kVA");
System.out.println("Weighted PF: " + loadList.getWeightedPowerFactor());
System.out.println(loadList.toJson());

9.3 Python/Jupyter

from neqsim import jneqsim

# After running process...
comp = process.getUnit("Export Compressor")
comp.initElectricalDesign()
ed = comp.getElectricalDesign()
ed.setRatedVoltageV(6600.0)
ed.setFrequencyHz(50.0)
ed.setUseVFD(True)
ed.calcDesign()

print(f"Motor: {ed.getMotor().getRatedPowerKW():.0f} kW")
print(f"Cable: {ed.getPowerCable().getCrossSectionMM2():.0f} mm²")
print(ed.toJson())

10. JSON Output Structure

{
  "equipmentName": "Export Compressor",
  "equipmentType": "Compressor",
  "shaftPowerKW": 4500.0,
  "electricalInputKW": 4950.0,
  "apparentPowerKVA": 5192.0,
  "reactivePowerKVAR": 1610.0,
  "powerFactor": 0.953,
  "ratedVoltageV": 6600,
  "frequencyHz": 50,
  "phases": 3,
  "motor": {
    "ratedPowerKW": 5000,
    "ratedVoltageV": 6600,
    "ratedCurrentA": 495.2,
    "ratedSpeedRPM": 2985,
    "poles": 2,
    "efficiencyPercent": 96.8,
    "efficiencyClass": "IE3",
    "powerFactorFL": 0.89,
    "frameSize": "450",
    "enclosureType": "TEFC",
    "insulationClass": "F",
    "exProtection": "Ex d IIB T3",
    "startingMethod": "VFD",
    "lockedRotorCurrentMultiplier": 6.5,
    "weightKg": 3200,
    "estimatedCostUSD": 185000
  },
  "vfd": {
    "ratedPowerKW": 5000,
    "ratedCurrentA": 520,
    "topologyType": "3-level",
    "efficiencyPercent": 97.5,
    "inputPowerFactor": 0.98,
    "thdCurrentPercent": 3.2,
    "pulseConfiguration": "AFE",
    "coolingMethod": "Water",
    "enclosureRating": "IP21",
    "weightKg": 2800,
    "estimatedCostUSD": 320000
  },
  "powerCable": {
    "lengthM": 150,
    "crossSectionMM2": 95,
    "conductorMaterial": "Copper",
    "insulationType": "XLPE",
    "numberOfCores": 3,
    "voltageDropPercent": 1.8,
    "ampacityA": 540,
    "installationMethod": "Tray"
  },
  "auxiliaryLoads": {
    "lubOilPumpKW": 15.0,
    "sealGasPanelKW": 5.0,
    "coolingFanKW": 22.0,
    "instrumentationKW": 2.0,
    "antiSurgeValveKW": 3.0,
    "totalAuxiliaryKW": 47.0
  },
  "hazardousArea": {
    "zone": "Zone 1",
    "gasGroup": "IIA",
    "temperatureClass": "T3"
  }
}

11. Implementation Roadmap

Phase 1 — Foundation (Priority: High) ✅ IMPLEMENTED

Task Description Status
1.1 Create ElectricalDesign base class with power/voltage/PF fields ✅ Done
1.2 Create ElectricalMotor component with IEC sizing logic ✅ Done
1.3 Create VariableFrequencyDrive component ✅ Done
1.4 Create ElectricalCable component with voltage drop calc ✅ Done
1.5 Add getElectricalDesign() / initElectricalDesign() to interface/base ✅ Done
1.6 Implement CompressorElectricalDesign (most valuable use case) ✅ Done
1.7 CSV data files for motor frames and cable ampacity ✅ Done (embedded in Java)
1.8 Unit tests for all Phase 1 classes ✅ Done

Phase 2 — Equipment Coverage ✅ IMPLEMENTED

Task Description Status
2.1 PumpElectricalDesign ✅ Done
2.2 SeparatorElectricalDesign (actuated valves, level instruments) ✅ Done
2.3 HeatExchangerElectricalDesign (electric heaters, fans for air coolers) ✅ Done
2.4 PipelineElectricalDesign (heat tracing, cathodic protection) ✅ Done
2.5 Transformer component ✅ Done
2.6 Switchgear component ✅ Done

Phase 3 — System Integration ✅ IMPLEMENTED

Task Description Status
3.1 ElectricalLoadList and LoadItem classes ✅ Done
3.2 ProcessSystem.getElectricalLoadList() ✅ Done
3.3 SystemElectricalDesign for plant-wide summary ✅ Done
3.4 Power balance report generation Planned
3.5 One-line diagram data export (JSON/XML) Planned

Phase 4 — Advanced Features (Partially Implemented)

Task Description Status
4.1 HazardousAreaClassification (ATEX/IECEx zone mapping) ✅ Done
4.2 Harmonic analysis for VFD installations Planned
4.3 Short-circuit current calculations Planned
4.4 ElectricalHeatTracing for pipeline insulation ✅ Done (via PipelineElectricalDesign)
4.5 Integration with cost estimation framework Planned
4.6 Subsea power distribution (power umbilicals, step-out distance) Planned

Phase 5 — Motor Mechanical Design & Combined Reports ✅ IMPLEMENTED

Task Description Status
5.1 MotorMechanicalDesign — physical motor design (weight, dimensions, cooling, foundation, vibration, bearings, noise, enclosure) per IEC 60034 / ISO 10816-3 / ISO 281 / NORSOK S-002 ✅ Done
5.2 setFromElectricalDesign() — link motor mechanical to electrical design results ✅ Done
5.3 Altitude and temperature derating per IEC 60034-1 ✅ Done
5.4 Foundation design (concrete block / steel skid) with bolt pattern ✅ Done
5.5 Vibration assessment per ISO 10816-3 (zones A/B/C/D) ✅ Done
5.6 NORSOK S-002 noise assessment (85 dB(A) at 1 m limit) ✅ Done
5.7 Bearing L10 life per ISO 281 ✅ Done
5.8 EquipmentDesignReport — combined mechanical + electrical + motor design report with FEASIBLE / FEASIBLE_WITH_WARNINGS / NOT_FEASIBLE verdict ✅ Done
5.9 toLoadListEntry() — electrical load list integration from combined report ✅ Done
5.10 Unit tests (22 tests covering all Phase 5 features) ✅ Done

12. Relationship to Existing Code

What changes in existing classes

Class Change Risk
ProcessEquipmentInterface Add 2 methods: getElectricalDesign(), initElectricalDesign() Low — default returns null
ProcessEquipmentBaseClass Add field + default implementations Low — backward compatible
ProcessSystem Add initAllElectricalDesigns(), runAllElectricalDesigns(), getElectricalLoadList() Low — additive only
Compressor Override initElectricalDesign(), getElectricalDesign() Low — follows existing pattern
Pump Same override pattern Low
Separator Override initElectricalDesign(), getElectricalDesign() — eager init in constructor Low
Heater / Cooler Override with lazy init (null-check in getter) Low — Cooler inherits from Heater
AdiabaticPipe / PipeBeggsAndBrills Override with lazy init (null-check in getter) Low

What stays the same

Interaction with MechanicalDesign

Both designs use the same process equipment as input but produce independent outputs:

Process Equipment (Compressor)
├── getPower("kW") → 4500 kW shaft power
│
├── MechanicalDesign → wall thickness, materials, weights, vessel design
│
├── ElectricalDesign → motor, VFD, cables, switchgear, load list
│
├── MotorMechanicalDesign → motor weight, foundation, vibration, bearings,
│                           cooling, noise, enclosure (IEC 60034 / ISO 10816-3)
│
└── EquipmentDesignReport → combined report with FEASIBLE verdict
        ├── runs MechanicalDesign.calcDesign()
        ├── runs ElectricalDesign.calcDesign()
        └── runs MotorMechanicalDesign.calcDesign()

The calcDesign() methods can reference each other if needed:


13. Key Design Decisions

Decision Rationale
Separate package (electricaldesign/) rather than merging into mechanicaldesign/ Electrical and mechanical are distinct engineering disciplines with different standards, professionals, and deliverables
Component composition (Motor, VFD, Cable as separate classes) Each component has independent sizing rules, standards, and is testable in isolation
Post-processing step (after process simulation) Electrical sizing depends on process duty (power), not the other way around
Data-driven sizing from CSV tables Motor frames, cable ampacity, etc. follow standard tables — hardcoding would be unmaintainable
Equipment-specific subclasses of ElectricalDesign Different equipment types have fundamentally different electrical requirements (motor vs heater element vs solenoid valve)
ElectricalMotor vs ElectricMotorDriver Driver class models dynamic speed-torque behavior; Motor class models rated nameplate and sizing. Similar to how a mechanical engineer specifies a vessel (MechanicalDesign) while a process engineer models its separation (Separator)

14. VSD/Compressor Use Case Deep Dive

The VSD + compressor combination is the most valuable initial use case:

What NeqSim Can Already Do

What the Electrical Package Adds

  1. Motor selection: Given 4500 kW shaft power → select 5000 kW motor (IEC frame 450, IE3)
  2. VFD selection: Given motor → select 5000 kW VFD (3-level, AFE, IP21)
  3. Harmonic impact: 6-pulse VFD → 28% THDi; AFE → 3% THDi → affects transformer/cable sizing
  4. Cable sizing: 6.6 kV, 150m run → 95 mm² XLPE, 1.8% voltage drop ✓
  5. Starting analysis: With VFD → soft-start, no inrush → smaller switchgear
  6. Heat dissipation: VFD losses = 125 kW → HVAC or water cooling requirement
  7. Power factor correction: VFD with AFE → PF ≈ 0.98 → no capacitor bank needed
  8. Cost: Motor $185k + VFD $320k + cables $45k = $550k electrical scope
  9. Load list entry: 5000 kW connected, 4500 kW absorbed, 0.89 PF, Zone 1 Ex d IIB T3

End-to-End Flow

Compressor.run()
  → shaft power = 4500 kW
  → Compressor.initElectricalDesign()
    → CompressorElectricalDesign.calcDesign()
      → ElectricalMotor.sizeMotor(4500, 1.10, "IEC")  → 5000 kW, Frame 450
      → VariableFrequencyDrive.sizeVFD(motor)          → 5000 kW, AFE
      → ElectricalCable.sizeCable(495A, 6600V, 150m)   → 95 mm² XLPE
      → Calculate apparentPower, reactivePower, powerFactor
      → Sum auxiliary loads (lube oil pump, seal gas, instruments)
  → CompressorElectricalDesign.toJson()
    → Complete equipment electrical data sheet