NeqSim 3.30.0
Status: in preparation. This page collects breaking changes and migration notes for the next minor release while it is being assembled on master. The POM version is bumped as part of the release preparation, not by the individual changes listed here.
Breaking changes
Legacy Aspen IP.21 online-signal integration removed
neqsim.util.database.AspenIP21Database,
neqsim.process.measurementdevice.online.OnlineSignal and the legacy signal
methods on MeasurementDeviceInterface / MeasurementDeviceBaseClass
(getOnlineSignal(), setOnlineSignal(OnlineSignal), isOnlineSignal(),
setIsOnlineSignal(boolean, String, String), getOnlineValue()) are removed.
They were deprecated in 3.25.0 (first published in 3.26.0, issue
#4186) and relied on the
sun.jdbc.odbc bridge driver, which no JDK since Java 8 ships, with a
placeholder connection string.
Migration:
- Acquire historian samples with an application-managed client and pass the
checked value and unit to
MeasurementDeviceBaseClass.setOnlineMeasurementValue(double, String); read it withgetOnlineMeasurementValue(). - Custom
MeasurementDeviceInterfaceimplementations must drop theirgetOnlineSignal()andisOnlineSignal()overrides. ProcessSystem.reportMeasuredValues()no longer prints an “Online value” line.ModelPredictiveControllerand all measurement devices no longer report an “external I/O” transient-state coverage blocker; that mode no longer exists.- P&ID engineering packages (
PidNativeControlSystem) no longer emit theonlineSignalkey in native instrument configurations. Packages exported earlier withonlineSignal: falsestill validate and apply;onlineSignal: trueis rejected. serialVersionUIDvalues are unchanged. Serialized measurement devices whoseonlineSignalfield wasnullstill deserialize. A stream containing a non-nullOnlineSignalinstance fails withClassNotFoundExceptionand must be recreated from its model inputs.
See the API lifecycle guidance and measurement devices.