Root Cause Analysis Framework

The neqsim.process.diagnostics package provides a structured root cause analysis (RCA) framework for diagnosing equipment operational anomalies. It integrates four evidence sources via Bayesian-inspired confidence scoring:

  1. Reliability Data — Prior probabilities from public reliability databases (IOGP/SINTEF, CCPS 1989, IEEE 493-2007, Lees 2012, SINTEF PDS) with optional OREDA overlay
  2. Historian — Likelihood scoring from time-series trend, threshold, and correlation analysis
  3. STID — Cross-reference against design conditions
  4. Autonomous findings — Hypothesis-specific anomaly and topology evidence
  5. Simulation — Coverage-qualified, magnitude-aware verification from NeqSim perturbation

Architecture

Symptom (enum)
    │
    ├── HypothesisGenerator  →  Generate candidate hypotheses
    │       │
    │       └── Reliability priors (ReliabilityDataSource)
    │           Sources: IOGP/SINTEF, CCPS, IEEE 493, Lees, OREDA
    │
    ├── EvidenceCollector     →  Analyze historian + STID data against expected signals
    │       │
    │       ├── Trend analysis (linear regression R²)
    │       ├── Threshold exceedance
    │       ├── Rate-of-change step detection (3σ)
    │       └── Pearson correlation (|r| > 0.7)
    │
    ├── AnomalyScanner + topology → Add matched autonomous evidence to ranking
    ├── SimulationVerifier    →  Clone, perturb, compare normalized response magnitude
    │
    └── RootCauseReport       →  Ranked hypotheses with confidence scores

Each built-in hypothesis carries expected signal fingerprints. For example, compressor bearing degradation expects increasing vibration and bearing temperature, while liquid ingestion expects a step change in vibration and high upstream separator or scrubber level. Evidence that matches the fingerprint is marked as supporting; opposite behavior is marked as contradictory; unrelated trends are ignored.

Diagnosing a flow discrepancy across connected equipment

A filling separator or a packing flowline can take in more mass than it delivers. Use ProcessBalanceDiagnosis.assess(window, inventoryChangeBoundsKg, meters) on a common historian window to test the physical explanations. The same calculation is available in the optional massBalance block of runRootCauseAnalysis. The nested result supplies independent evidence alongside the ordinary RCA rankings.

Define the measurement boundary

Identify non-overlapping control volumes on the P&ID. Supply each total inventory in kg, including gas, oil and water as applicable. A level signal alone needs a level-to-volume curve, phase densities and an allowance for their uncertainty. Use signed instantaneous kg/s for every boundary crossing, including vents, drains and recycle crossings where measured. Give a shared transfer meter one tag and connect it to both volumes. A recycle wholly within one volume cancels. Record the clock basis, tag quality, unit conversion, operating mode and source of each bound. Split windows at gaps or cadence changes. Compressed event samples and interval-average meters need preprocessing on an appropriate basis.

For a window of duration $T=(n-1)\Delta t$, the signed residual for volume $j$ is

\[r_j = \sum_e A_{je}\overline{q}_e - (M_{j,n}-M_{j,1})/T.\]

Here $A$ is +1 for inflow and −1 for outflow, and the mean of each meter is trapezoidally integrated. Its absolute error budget is the sum of the incident healthy meter bounds in kg/s plus the supplied inventory-change bound divided by $T$. Include integration, timing and inventory-model error in the budget. For independent endpoint measurements with only absolute bounds available, summing both endpoint bounds is conservative. A constant inventory offset cancels. These are user-supplied engineering limits, with no distributional or probability interpretation.

Each candidate must fit all balances using the same signed healthy error for every shared meter. A high-reading shared meter gives a negative residual upstream and a positive one downstream. An unmetered outflow gives a positive residual only at its own volume. The solver bounds the compatible mean rate subject to all meter and inventory errors simultaneously. It screens the listed single faults. Variable deviations can cancel within a window. Inventory drift, omitted transfers and simultaneous faults can mimic a listed candidate.

Result Interpretation and next check
WITHIN_BOUNDS One set of healthy measurement errors explains every balance. Document the smallest discrepancy the measurements could resolve.
SINGLE_CANDIDATE One listed signature fits. Confirm independently, for example with a redundant flow measurement.
AMBIGUOUS Report every surviving candidate and signed rate interval. A single vessel’s balance alone can confound an underestimated export and an unmetered outflow.
UNEXPLAINED No listed single fault fits all volumes. Recheck inventory conversion, timing, omitted streams and overlapping faults.

Worked separator and receiver case

Over 2 s, the feed samples are 6, 10 and 6 kg/s. Gas leaves at 2 kg/s, liquid transfers at 3 kg/s and the receiver exports 2 kg/s. Separator inventory rises from 100 to 106 kg and receiver inventory from 50 to 52 kg. Both balances close. Adding a +1 kg/s measurement bias on the shared liquid transfer gives residuals of −1 and +1 kg/s. With an absolute bound of 0.02 kg/s for each meter and change bounds of 0.08 kg and 0.12 kg respectively, the shared meter is the only listed candidate and its signed bias interval is +0.90 to +1.10 kg/s.

To reproduce the biased case, add this property to an existing equipment RCA request. The sample arrays correspond to 0, 1 and 2 s.

{
  "massBalance": {
    "sampleIntervalSeconds": 1,
    "signals": {
      "separator_kg": [100, 103, 106], "receiver_kg": [50, 51, 52],
      "feed": [6, 10, 6], "gas": [2, 2, 2], "transfer": [4, 4, 4], "export": [2, 2, 2]
    },
    "inventoryChangeBoundsKg": {"separator_kg": 0.08, "receiver_kg": 0.12},
    "meters": [
      {"tag": "feed", "from": null, "to": "separator_kg", "errorKgPerS": 0.02},
      {"tag": "gas", "from": "separator_kg", "to": null, "errorKgPerS": 0.02},
      {"tag": "transfer", "from": "separator_kg", "to": "receiver_kg", "errorKgPerS": 0.02},
      {"tag": "export", "from": "receiver_kg", "to": null, "errorKgPerS": 0.02}
    ]
  }
}

Literature and qualification

Source Application to troubleshooting
Venkatasubramanian et al. (2003), quantitative model-based diagnosis and qualitative models Use conservation equations to calculate residuals and the flowsheet to explain their signs.
PHMSA study, Appendix C Inventory change and meter uncertainty enter the assessment during pipeline transients.
Han et al. (2004), industrial inventory reconciliation Redundant inventory and flow measurements can help distinguish calibration errors from process changes.
Synchronized node imbalances (2007) Time alignment and process dynamics change how node discrepancies can be interpreted for sensor biases and losses. Here, measured inventory change supplies the accumulation term.
FPSO three-phase separator diagnosis (2026) Sparse labelled incidents motivate expert hypotheses. The balance screen gives those hypotheses an independent physical consistency check when the required tags exist.
Stief et al. (2018), multiphase flow facility Assess alarms and measurements against separately labelled normal and seeded-fault runs at more than one operating point.
Vargas et al. (2019), offshore well events The Petrobras 3W benchmark supports well-event classification. Its well-event labels alone cannot establish topside balance accuracy.

The analytic regressions exercise healthy accumulation, signed transfer bias, local diversion, shared-error cancellation, uncertainty thresholds and incompatible faults. A PR-EOS gas/condensate separator test withholds a 20% diversion of the gas stream and compares the recovered missing flow against the independently simulated splitter branch. The committed small-network test compares every feasible candidate and both rate endpoints with exhaustive control-volume subset balances in 120 seeded cases with two to six inventories. Field qualification requires synchronized inventories and metering with independently established events. Reserve entire operating runs for testing and report event-level false alarms, missed events, time to detection and ambiguous diagnoses by regime.

Confidence Scoring

Each hypothesis receives a confidence score calculated as:

\[\text{confidence} = P_{\text{prior}} \times L_{\text{historian}} \times V_{\text{simulation}}\]

Where:

Likelihood and verification each carry an EvaluationStatus: UNKNOWN, EVALUATED, UNSUPPORTED, or FAILED. Only EVALUATED scores participate in the product. An evaluated score of exactly zero is contradictory evidence, while a stage that was not run or could not run remains explicitly neutral. JSON includes both statuses plus simulation KPI coverage and comparison count.

Reproducible Diagnosis Cases

DiagnosisCase records the equipment, historian time window, source provenance, process-model identity/revision, operating context, and data-quality metadata. Attach an explicit case when source query IDs or model revisions are known; otherwise the analyzer derives a minimal case and historian quality counts.

DiagnosisCase diagnosisCase = new DiagnosisCase("Export Compressor")
    .setCaseId("trip-2026-07-19")
    .setTimeWindow(1784480400.0, 1784484000.0)
    .setProcessModel("export-compression", "model-rev-7")
    .addDataSource("PI", "compressed-query-id-42")
    .addOperatingContext("mode", "recycle")
    .addDataQuality("coverage", "98%");
rca.setDiagnosisCase(diagnosisCase);

Data Sources

ReliabilityDataSource loads failure rates and repair times from multiple public databases, requiring no commercial license:

Source Coverage Access
IOGP Report 434 / SINTEF Offshore O&G equipment, safety systems Free
CCPS Process Equipment Reliability Data (1989) Vessels, piping, instruments, valves Published handbook
IEEE 493-2007 (Gold Book) Industrial power and electrical equipment Purchasable standard
Lees’ Loss Prevention (2012) Generic process industry failure rates Textbook
SINTEF PDS Data Handbook Safety-instrumented system failure rates Purchasable
API 689 Rotating and process equipment reliability Purchasable standard
OREDA (optional) Offshore equipment (consortium license) Commercial

Supplementary CSVs are loaded automatically. Primary data takes precedence over supplementary entries, so users can override any value by editing equipment_reliability.csv.

Supported Equipment Types

Equipment Type Symptoms Hypothesis Categories
Compressor HIGH_VIBRATION, HIGH_TEMPERATURE, LOW_EFFICIENCY, SURGE_EVENT, TRIP Bearing wear, seal leak, fouling, surge, valve fault
Pump HIGH_VIBRATION, LOW_EFFICIENCY, TRIP Cavitation, impeller wear, seal failure, motor fault
Separator LIQUID_CARRYOVER, PRESSURE_DEVIATION, FOULING Demister damage, control malfunction, wax/hydrate, inlet device
Heat Exchanger HIGH_TEMPERATURE, LOW_EFFICIENCY, PRESSURE_DEVIATION Fouling, tube leak, baffle damage, bypass
Valve FLOW_DEVIATION, ABNORMAL_NOISE Trim erosion, actuator fault, positioner drift, cavitation

Java Usage

import neqsim.process.diagnostics.*;

// Build process
ProcessSystem process = ...; // existing process model
process.run();

// Create analyzer
RootCauseAnalyzer rca = new RootCauseAnalyzer(process, "Export Compressor");
rca.setSymptom(Symptom.HIGH_VIBRATION);

// Optional: add historian data
Map<String, double[]> data = new HashMap<>();
data.put("vibration_mm_s", new double[]{2.1, 2.3, 2.8, 3.5, 4.2});
data.put("bearing_temp_C", new double[]{65, 67, 72, 78, 85});
double[] timestamps = {0, 1, 2, 3, 4};
rca.setHistorianData(data, timestamps);

// Optional: design limits
rca.setDesignLimit("vibration_mm_s", 0.0, 4.5);

// Run analysis
RootCauseReport report = rca.analyze();

// Output
String textReport = report.toTextReport();
String json = report.toJson();

Python (Jupyter) Usage

RootCauseAnalyzer = ns.JClass("neqsim.process.diagnostics.RootCauseAnalyzer")
Symptom = ns.JClass("neqsim.process.diagnostics.Symptom")

rca = RootCauseAnalyzer(process, "Export Compressor")
rca.setSymptom(Symptom.HIGH_VIBRATION)
report = rca.analyze()

# Get JSON report
import json
result = json.loads(str(report.toJson()))
for h in result["hypotheses"]:
    print(f"{h['rank']}. {h['name']} — confidence: {h['confidenceScore']:.3f}")

MCP Tool

The runRootCauseAnalysis MCP tool exposes this framework to LLM agents:

{
    "processJson": "{\"fluid\": {...}, \"process\": [...]}",
    "equipmentName": "Export Compressor",
    "symptom": "HIGH_VIBRATION",
    "historianCsv": "timestamp,vibration,bearing_temp\n0,2.1,65\n1,2.3,67\n2,2.8,72",
    "designLimits": { "vibration": [0, 4.5] },
    "simulationEnabled": true,
    "diagnosisCase": {
        "caseId": "trip-2026-07-19",
        "processModelId": "export-compression",
        "processModelRevision": "model-rev-7",
        "dataSources": { "PI": "compressed-query-id-42" },
        "operatingContext": { "mode": "recycle" },
        "dataQuality": { "coverage": "98%" }
    }
}

processJson is passed as a JSON string to the MCP runner. The schema catalog entry run_root_cause_analysis shows the exact input fields and output shape. The returned diagnosisCase object and per-hypothesis evaluation statuses are additive, so consumers of the existing report fields continue to work.

Custom Hypotheses

Register domain-specific hypotheses for specialized equipment:

HypothesisGenerator generator = new HypothesisGenerator();
generator.register("compressor", Symptom.HIGH_VIBRATION,
    new Hypothesis.Builder()
        .name("Coupling misalignment")
        .description("Flexible coupling misalignment causing 1x/2x vibration")
        .category(Hypothesis.Category.MECHANICAL)
        .priorProbability(0.15)
        .addExpectedSignal("vibration|2x|axialVibration", Hypothesis.ExpectedBehavior.INCREASE,
            2.5, "Misalignment normally increases axial and 2x vibration")
        .addAction("Laser alignment check")
        .build());

RootCauseAnalyzer rca = new RootCauseAnalyzer(process, "Compressor");
rca.setHypothesisGenerator(generator);

Classes

Class Description
Symptom Enum of 12 observable symptoms (TRIP, HIGH_VIBRATION, etc.)
Hypothesis Ranked failure hypothesis with evidence, confidence, and actions
HypothesisGenerator Registry-based generator with built-in equipment libraries
EvidenceCollector Time-series analysis (trend, threshold, correlation)
DiagnosisCase Reproducible window, provenance, model identity, context, and quality metadata
SimulationVerifier Process perturbation with explicit status, KPI coverage, and magnitude-aware scoring
RootCauseReport Ranked report with JSON, text, and results map output
RootCauseAnalyzer Main orchestrator integrating all components