Skip to the content.

Export a well as OLGA GENKEY text

OlgaWellGenkeyExporter converts a liquid inflow-performance relationship and a well trajectory into an OLGA GENKEY fragment. It emits case-level MATERIAL, WALL, and TABULAR declarations followed by a NETWORKCOMPONENT TYPE=FLOWPATH block containing GEOMETRY, PIPE, HEATTRANSFER, and RESERVOIRCONTACT keywords.

The class is a format generator, not an OLGA simulator. A licensed OLGA installation is still required to embed the fragment in a complete case, run OLGA’s rule check, and qualify the model for its intended decision. An independent design review must confirm the fluid, geometry, thermal basis, material properties, discretisation, and well-deliverability inputs.

Inputs that remain the caller’s responsibility

Input Required engineering basis
Inflow performance A calibrated or explicitly screening InflowPerformance with pressure and liquid-rate units checked
Trajectory Real planned/as-drilled survey data whenever available; otherwise an explicitly disclosed synthetic screening trajectory
Pipe Per-segment inner diameter and reviewed roughness
Wall Thickness, material label, conductivity, heat capacity, and density
Thermal boundary Overall heat-transfer coefficient and ambient temperature
Reservoir Bottom-hole/reservoir temperature
PVT A separately generated OLGA fluid table and its exact label, if the optional FLUID= linkage is used

The exporter deliberately supplies no engineering defaults for those values. It also does not invent a choke or Cv table, segment grading, gas-oil ratio, or water-gas ratio. Each consecutive trajectory-node pair becomes one PIPE with NSEGMENT=1; provide additional reviewed nodes when finer resolution is needed.

Coordinate and array contract

setTrajectory(xMetre, yMetre, diameterMetre) accepts one x/y coordinate pair per node and one diameter per segment. Therefore diameterMetre.length == xMetre.length - 1. The OLGA elevation convention used by the exporter is y negative with depth.

SyntheticWellTrajectory returns measured depth (MD) and true vertical depth (TVD), not OLGA x/y coordinates. The example below derives horizontal displacement for each station from sqrt(deltaMD^2 - deltaTVD^2) and maps TVD to negative y. Use this conversion only for a planar screening profile. A real survey can contain azimuth changes and must be projected with its reviewed coordinate reference system instead.

Complete Java 8 example

The numbers below are invented, round tutorial fixtures so the program remains executable. They are not field data or recommended defaults. Replace every fixture with the approved basis for the well, retain its provenance, and replace the synthetic trajectory with a real survey as soon as one is available. Run the program with Java assertions enabled (for example, java -ea OlgaWellGenkeyExportExample).

import java.util.Arrays;
import neqsim.process.equipment.reservoir.InflowPerformance;
import neqsim.process.fielddevelopment.olga.OlgaWellGenkeyExporter;
import neqsim.process.fielddevelopment.olga.SyntheticWellTrajectory;

public final class OlgaWellGenkeyExportExample {
  private static final double TUBING_INNER_DIAMETER_METRE = 0.124;

  private OlgaWellGenkeyExportExample() {}

  public static void main(String[] args) {
    SyntheticWellTrajectory.Statistics statistics =
        new SyntheticWellTrajectory.Statistics(
            new SyntheticWellTrajectory.DepthTier[] {
              new SyntheticWellTrajectory.DepthTier(
                  "shallow", 10, 2.0, 200.0, 1000.0),
              new SyntheticWellTrajectory.DepthTier(
                  "medium", 10, 1.0, 400.0, 2000.0),
              new SyntheticWellTrajectory.DepthTier(
                  "deep", 10, 0.5, 600.0, 3000.0)
            },
            80.0,
            "Tutorial fixture only; invented values, not a real well population.");

    SyntheticWellTrajectory.Result trajectory =
        SyntheticWellTrajectory.generateSyntheticTrajectory(
            2500.0, 300.0, null, 8, statistics);

    double[] xMetre = horizontalCoordinates(trajectory);
    double[] yMetre = negativeTvdCoordinates(trajectory);
    double[] diameterMetre = new double[xMetre.length - 1];
    Arrays.fill(diameterMetre, TUBING_INNER_DIAMETER_METRE);

    InflowPerformance ipr = InflowPerformance.composite(200.0, 70.68, 66.94);
    OlgaWellGenkeyExporter exporter = new OlgaWellGenkeyExporter("WELL-1");
    exporter.setTrajectory(xMetre, yMetre, diameterMetre);
    exporter.setInflowPerformance(ipr);
    exporter.setReservoirTemperature(90.0, "C");
    exporter.setPipeRoughness(2.0e-5, "m");
    exporter.setWall(
        0.012, "m", "CARBON_STEEL", 50.0, 500.0, 7850.0);
    exporter.setHeatTransfer(6.5, "W/m2-C", 6.0, "C");

    String genkeyText = exporter.toGenkeyText();
    String disclosure =
        SyntheticWellTrajectory.syntheticTrajectoryWarning(trajectory);

    assert "synthetic_template".equals(trajectory.provenance);
    assert disclosure.startsWith(
        SyntheticWellTrajectory.SYNTHETIC_TRAJECTORY_WARNING_PREFIX);
    assert diameterMetre.length == xMetre.length - 1;
    assert genkeyText.contains("MATERIAL");
    assert genkeyText.contains("WALL");
    assert genkeyText.contains("TABULAR");
    assert genkeyText.contains("NETWORKCOMPONENT TYPE=FLOWPATH");
    assert genkeyText.contains("GEOMETRY");
    assert genkeyText.contains("PIPE");
    assert genkeyText.contains("HEATTRANSFER");
    assert genkeyText.contains("RESERVOIRCONTACT");
  }

  private static double[] horizontalCoordinates(
      SyntheticWellTrajectory.Result trajectory) {
    double[] xMetre = new double[trajectory.md.length];
    for (int i = 1; i < xMetre.length; i++) {
      double deltaMd = trajectory.md[i] - trajectory.md[i - 1];
      double deltaTvd = trajectory.tvd[i] - trajectory.tvd[i - 1];
      double horizontalSquared =
          Math.max(0.0, deltaMd * deltaMd - deltaTvd * deltaTvd);
      xMetre[i] = xMetre[i - 1] + Math.sqrt(horizontalSquared);
    }
    return xMetre;
  }

  private static double[] negativeTvdCoordinates(
      SyntheticWellTrajectory.Result trajectory) {
    double[] yMetre = new double[trajectory.tvd.length];
    for (int i = 0; i < yMetre.length; i++) {
      yMetre[i] = -trajectory.tvd[i];
    }
    return yMetre;
  }
}

The generated text is an embeddable fragment. It is not a complete OLGA case and the example does not write a file. If a reviewed file is needed, use writeTo(Path) with an application-controlled destination.

Synthetic trajectory governance

SyntheticWellTrajectory contains no statistics dataset. The caller must construct Statistics from data it is permitted to use and supply a specific basisDescription. Preserve SyntheticWellTrajectory.syntheticTrajectoryWarning(result) alongside the model and inspect result.warnings; the canonical warning is non-empty even when the generation itself produces no exceptional warning.

A synthetic profile is screening evidence only. It is not a planned or as-drilled survey, does not represent doglegs, S-shaped paths, multi-target geometry, or azimuth changes, and must never be presented as the real well. Replace it with approved Prosper, SMDA, drilling-engineering, or survey data before design- or safety-relevant OLGA work.

Optional PVT linkage

Calling setPvtFluidLabel("MY_FLUID") only adds a FLUID= reference to the fragment. It does not generate PVT data. The label must exactly match a fluid table already produced and qualified for the complete OLGA case. See OLGA PVT table generation for the separate PVT workflow.

Qualification checklist

  1. Replace all tutorial fixtures with traceable, unit-checked project inputs.
  2. Prefer a real trajectory and document the coordinate projection.
  3. Confirm that every segment diameter maps to the intended node pair.
  4. Embed the fragment in the complete case with its qualified PVT fluid.
  5. Run the licensed OLGA rule check and resolve every diagnostic.
  6. Compare the resulting pressure, temperature, rate, and transient behaviour with independent evidence suitable for the decision.
  7. Retain the input basis, generated fragment, rule-check output, and review record.