MPC Integration for NeqSim Process Systems
This document describes the Model Predictive Control (MPC) integration package for NeqSim, which bridges the gap between rigorous process simulation and advanced control systems.
Overview
The neqsim.process.mpc package provides seamless integration between NeqSim’s thermodynamic process simulation (ProcessSystem) and Model Predictive Control. It enables:
- Automatic Model Identification - Calculate Jacobian matrices or step responses directly from the simulation
- Variable Binding - Link MPC variables (MVs, CVs, DVs) to process equipment properties
- Nonlinear Prediction - Use full NeqSim simulation for multi-step prediction
- Model Export - Export state-space models to JSON, CSV, or MATLAB format
Architecture
┌─────────────────────────────────────────────────────────────────────────────┐
│ ProcessLinkedMPC │
│ (High-level bridge between ProcessSystem and MPC) │
├─────────────────────────────────────────────────────────────────────────────┤
│ │
│ ┌─────────────┐ ┌─────────────┐ ┌─────────────┐ ┌─────────────┐ │
│ │ Manipulated │ │ Controlled │ │ Disturbance │ │ State │ │
│ │ Variable │ │ Variable │ │ Variable │ │ Variable │ │
│ │ (MV) │ │ (CV) │ │ (DV) │ │ (SVR) │ │
│ └──────┬──────┘ └──────┬──────┘ └──────┬──────┘ └──────┬──────┘ │
│ │ │ │ │ │
│ └────────────────┴────────────────┴────────────────┘ │
│ │ │
│ ┌──────────────────────────┼──────────────────────────┐ │
│ ▼ ▼ ▼ │
│ ┌─────────────────┐ ┌─────────────────────────┐ ┌─────────────────┐ │
│ │ ProcessLinear- │ │ StepResponse- │ │ Nonlinear- │ │
│ │ izer │ │ Generator │ │ Predictor │ │
│ └────────┬────────┘ └───────────┬─────────────┘ └────────┬────────┘ │
│ │ │ │ │
│ └───────────────────────┼──────────────────────────┘ │
│ ▼ │
│ ┌───────────────────────────┐ │
│ │ LinearizationResult │ │
│ │ (Gain matrices + OP) │ │
│ └─────────────┬─────────────┘ │
│ │ │
│ ┌───────────────────────────────┼───────────────────────────────┐ │
│ │ │ │ │
│ ▼ ▼ ▼ │
│ ┌──────────────┐ ┌────────────────────────┐ ┌────────────────────┐ │
│ │ StateSpace- │ │ IndustrialMPC- │ │ SubrModl- │ │
│ │ Exporter │ │ Exporter │ │ Exporter │ │
│ │(JSON/MATLAB) │ │(Step Response/Config) │ │ (Nonlinear Model) │ │
│ └──────────────┘ └────────────────────────┘ └────────────────────┘ │
│ │ │
│ ┌────────────────────────────┴────────────────────────────┐ │
│ │ │ │
│ ▼ ▼ │
│ ┌─────────────────────────┐ ┌─────────────────────────┐ │
│ │ ControllerDataExchange │ │ SoftSensorExporter │ │
│ │ (Real-time PCS I/O) │ │ (Estimator Configs) │ │
│ └─────────────────────────┘ └─────────────────────────┘ │
│ │
└──────────────────────────────────┬───────────────────────────────────────────┘
│
▼
┌─────────────────────┐
│ ProcessSystem │
│ (NeqSim Simulation)│
└─────────────────────┘
Quick Start
Basic MPC Setup
import neqsim.process.mpc.*;
import neqsim.process.processmodel.ProcessSystem;
import neqsim.process.equipment.separator.Separator;
import neqsim.process.equipment.stream.Stream;
import neqsim.process.equipment.valve.ThrottlingValve;
import neqsim.thermo.system.SystemSrkEos;
// Create fluid
SystemInterface fluid = new SystemSrkEos(298.15, 50.0);
fluid.addComponent("methane", 0.8);
fluid.addComponent("ethane", 0.15);
fluid.addComponent("propane", 0.05);
fluid.setMixingRule("classic");
// Build process
ProcessSystem process = new ProcessSystem();
Stream feed = new Stream("feed", fluid);
feed.setFlowRate(1000.0, "kg/hr");
feed.setTemperature(25.0, "C");
feed.setPressure(50.0, "bara");
ThrottlingValve valve = new ThrottlingValve("inlet_valve", feed);
valve.setOutletPressure(30.0);
Separator separator = new Separator("separator", valve.getOutletStream());
process.add(feed);
process.add(valve);
process.add(separator);
process.run();
// Create linked MPC
ProcessLinkedMPC mpc = new ProcessLinkedMPC("pressureController", process);
// Define variables
mpc.addMV("inlet_valve", "opening", 0.0, 1.0); // Valve opening 0-100%
mpc.addCV("separator", "pressure", 30.0); // Control to 30 bar
// Identify the local steady-gain model
mpc.identifyModel(60.0);
// Control loop
for (int step = 0; step < 100; step++) {
double[] moves = mpc.step();
System.out.printf("Step %d: MV=%.3f CV=%.2f%n",
step, moves[0], mpc.getCurrentCVs()[0]);
}
Variable Types
Manipulated Variables (MVs)
MVs are process inputs that the controller can adjust:
// Create MV with basic bounds
ManipulatedVariable mv = mpc.addMV("valve", "opening", 0.0, 1.0);
// Create MV with rate limit
ManipulatedVariable mv2 = mpc.addMV("heater", "duty", 0.0, 1000.0, 100.0);
// Rate limit: max 100 kW change per sample
// Set move suppression cost
mpc.setMoveSuppressionWeight("valve.opening", 0.5);
Supported MV Properties:
opening- Valve opening (0-1)duty- Heater/cooler duty (kW)flowRate- Stream flow ratespeed- Compressor/pump speedoutletPressure- Pressure controller setpoint
Controlled Variables (CVs)
CVs are process outputs that we want to control:
// Setpoint control
ControlledVariable cv = mpc.addCV("separator", "pressure", 30.0);
cv.setWeight(1.0); // CV priority
// Zone control (CV only needs to stay within bounds)
ControlledVariable cv2 = mpc.addCVZone("separator", "liquidLevel", 30.0, 70.0);
// Hard constraints
mpc.setConstraint("separator", "pressure", 25.0, 35.0);
Supported CV Properties:
pressure- Equipment pressure (bar)temperature- Stream/equipment temperature (°C or K)liquidLevel- Separator liquid level (%)flowRate- Stream flow ratequality- Vapor fraction
Disturbance Variables (DVs)
DVs are measured but uncontrolled disturbances for feedforward:
DisturbanceVariable dv = mpc.addDV("feed", "flowRate");
Model Identification
Linearization Method
Fast identification using finite differences:
mpc.identifyModel(60.0); // 60 second sample time
// Access results
LinearizationResult result = mpc.getLinearizationResult();
double[][] gains = result.getGainMatrix();
double gain = result.getGain("separator.pressure", "valve.opening");
Step Response Method
More accurate for highly nonlinear processes:
mpc.identifyModelFromStepTests(
60.0, // Sample time (seconds)
600.0, // Test duration per step (seconds)
5.0 // Step size (% of range)
);
Direct Linearizer Access
For more control over the identification process:
ProcessLinearizer linearizer = new ProcessLinearizer(process);
linearizer.setRelativePerturbation(0.01); // 1% perturbation
linearizer.setUseCentralDifference(true);
// Add variables
linearizer.addMV(new ManipulatedVariable("valve.opening", valve, "opening"));
linearizer.addCV(new ControlledVariable("sep.pressure", separator, "pressure"));
// Linearize
LinearizationResult result = linearizer.linearize();
// Check linearity
boolean isLinear = linearizer.checkLinearity(0.05); // 5% tolerance
Model Export
Export models for external MPC systems:
StateSpaceExporter exporter = mpc.exportModel();
// Generate discrete state-space model
StateSpaceExporter.StateSpaceModel model = exporter.toDiscreteStateSpace(60.0);
// Export to JSON (for Python)
exporter.exportJSON("process_model.json");
// Export to MATLAB
exporter.exportMATLAB("process_model.m");
// Export to CSV
exporter.exportCSV("model_"); // Creates model_A.csv, model_B.csv, etc.
JSON Format
{
"sampleTime": 60.0,
"sampleTimeUnit": "seconds",
"numStates": 2,
"numInputs": 1,
"numOutputs": 2,
"inputNames": ["valve.opening"],
"outputNames": ["separator.pressure", "separator.liquidLevel"],
"A": [[0.95, 0.0], [0.0, 0.98]],
"B": [[0.5], [0.1]],
"C": [[1.0, 0.0], [0.0, 1.0]],
"D": [[0.0], [0.0]]
}
MATLAB Format
% NeqSim State-Space Model Export
A = [0.95 0.0; 0.0 0.98];
B = [0.5; 0.1];
C = [1.0 0.0; 0.0 1.0];
D = [0.0; 0.0];
Ts = 60.0;
sys = ss(A, B, C, D, Ts);
sys.InputName = {'valve.opening'};
sys.OutputName = {'separator.pressure', 'separator.liquidLevel'};
Nonlinear Prediction
Use NonlinearPredictor to evaluate a specified input trajectory with process simulation.
ProcessLinkedMPC.calculate() uses the local gain model by default. Supplying sampled step responses
selects its linear horizon optimizer, as shown in the export/injection example below.
Direct Predictor Access
NonlinearPredictor predictor = new NonlinearPredictor(process, 60.0, 20);
// Add variables
predictor.addMV(new ManipulatedVariable("valve.opening", valve, "opening"));
predictor.addCV(new ControlledVariable("sep.pressure", separator, "pressure"));
// Create trajectory
NonlinearPredictor.MVTrajectory trajectory = new NonlinearPredictor.MVTrajectory();
double[] valveTrajectory = new double[20];
Arrays.fill(valveTrajectory, 0.6); // Constant 60% opening
trajectory.addMV("valve.opening", valveTrajectory);
// Predict
NonlinearPredictor.PredictionResult result = predictor.predict(trajectory);
double[] pressurePrediction = result.getCVTrajectory("separator.pressure");
Advanced Features
Model Updating
Enable automatic model updates during operation:
mpc.setModelUpdateInterval(100); // Re-linearize every 100 steps
Constraint Handling
// CV hard constraints (must be satisfied)
ControlledVariable cv = mpc.getControlledVariables().get(0);
cv.setHardConstraints(true);
cv.setMinValue(25.0);
cv.setMaxValue(35.0);
// CV soft constraints (penalty-based)
cv.setHardConstraints(false);
cv.setConstraintViolationCost(100.0);
Zone Control
// CV only penalized when outside zone
ControlledVariable cv = mpc.addCVZone("tank", "level", 30.0, 70.0);
// Controller only acts when level leaves 30-70% zone
Step Response Generator
For detailed model identification:
StepResponseGenerator generator = new StepResponseGenerator(process);
// Add variables
generator.addMV(mv);
generator.addCV(cv);
// Configure
generator.setStepDuration(600.0); // 10 minutes per test
generator.setStepSize(0.05); // 5% steps
generator.setSampleInterval(10.0); // 10 second samples
generator.setBidirectional(true); // Test both directions
// Generate all responses
StepResponseGenerator.StepResponseMatrix matrix = generator.generateAllResponses();
// Access individual responses
StepResponse response = matrix.get("separator.pressure", "valve.opening");
double gain = response.getGain();
double timeConstant = response.getTimeConstant();
double deadTime = response.getDeadTime();
// Export for DMC
StateSpaceExporter exporter = new StateSpaceExporter(matrix);
exporter.exportStepCoefficients("dmc_model.csv", 60);
Integration with AI Platforms
The MPC integration package is designed for seamless integration with AI/ML platforms:
Python Integration via neqsim-python
import jpype
import neqsim
# Access MPC classes
ProcessLinkedMPC = jpype.JClass('neqsim.process.mpc.ProcessLinkedMPC')
StateSpaceExporter = jpype.JClass('neqsim.process.mpc.StateSpaceExporter')
# Create MPC (assuming process is already set up)
mpc = ProcessLinkedMPC("controller", process)
mpc.addMV("valve", "opening", 0.0, 1.0)
mpc.addCV("separator", "pressure", 30.0)
mpc.identifyModel(60.0)
# Export model
exporter = mpc.exportModel()
exporter.exportJSON("model.json")
# Load in Python for custom optimization
import json
with open("model.json") as f:
model = json.load(f)
A = np.array(model['A'])
B = np.array(model['B'])
# Use with scipy.signal, python-control, or custom MPC
Real-Time Control Loop
// Configure for real-time
mpc.setSampleTime(1.0); // 1 second
mpc.setPredictionHorizon(60);
mpc.setControlHorizon(10);
mpc.identifyModel(1.0);
// Real-time loop
ScheduledExecutorService executor = Executors.newSingleThreadScheduledExecutor();
executor.scheduleAtFixedRate(() -> {
try {
// Read current measurements (from OPC, etc.)
updateProcessMeasurements(process);
// Calculate and apply control
mpc.step();
// Write outputs (to OPC, etc.)
writeProcessOutputs(mpc.getLastMoves());
} catch (Exception e) {
logger.error("Control error", e);
}
}, 0, 1000, TimeUnit.MILLISECONDS);
Best Practices
-
Start with linearization - Use
identifyModel()first; only switch to step response testing if needed for accuracy. -
Check linearity - Use
ProcessLinearizer.checkLinearity()to validate the linearization accuracy. -
Conservative tuning - Start with larger prediction horizons and move suppression weights, then tighten.
-
Model updates - Enable periodic re-linearization for processes with significant nonlinearity.
-
Constraint margins - Leave margin between operational constraints and safety limits.
-
Test in simulation - Validate controller behavior thoroughly before connecting to real equipment.
Package Structure
neqsim/process/mpc/
├── package-info.java # Package documentation
├── MPCVariable.java # Base class for MPC variables
├── ManipulatedVariable.java # Manipulated variable (MV)
├── ControlledVariable.java # Controlled variable (CV)
├── DisturbanceVariable.java # Disturbance variable (DV)
├── StateVariable.java # State variable (SVR) for nonlinear MPC
├── ProcessLinearizer.java # Automatic Jacobian calculation
├── LinearizationResult.java # Gain matrices container
├── StepResponse.java # Single MV-CV step response
├── StepResponseGenerator.java # Automated step testing
├── NonlinearPredictor.java # Full simulation prediction
├── StateSpaceExporter.java # Model export (JSON/CSV/MATLAB)
├── ProcessLinkedMPC.java # Main bridge class
├── IndustrialMPCExporter.java # Step response & config export for industrial MPC
├── ControllerDataExchange.java # Real-time data exchange interface
├── SoftSensorExporter.java # Soft-sensor/estimator configurations
└── SubrModlExporter.java # Nonlinear model export (SubrModl format)
Industrial Control System Integration
The MPC package includes comprehensive support for integration with industrial MPC platforms.
Step Response Model Export
Export models in formats compatible with industrial MPC systems:
IndustrialMPCExporter exporter = mpc.createIndustrialExporter();
exporter.setTagPrefix("UNIT1.separator");
exporter.setApplicationName("GasProcessing");
// Export step response coefficients in CSV format
exporter.exportStepResponseCSV("step_responses.csv");
// Export gain matrix
exporter.exportGainMatrix("gains.csv");
// Export complete object structure for configuration
exporter.exportObjectStructure("controller_config.json");
// Export comprehensive configuration with all model data
exporter.exportComprehensiveConfiguration("mpc_config.json");
Real-Time Data Exchange
Interface with Process Control Systems (PCS) using standardized data exchange:
ControllerDataExchange exchange = mpc.createDataExchange();
exchange.setTagPrefix("UNIT1.MPC");
// Control loop with external controller
while (running) {
// Update inputs from process measurements
exchange.updateInputs(mvValues, cvValues, dvValues);
exchange.updateSetpoints(setpoints);
exchange.updateLimits(cvLowLimits, cvHighLimits, mvLowLimits, mvHighLimits);
// Execute and get outputs
exchange.execute();
ControllerDataExchange.ControllerOutput output = exchange.getOutputs();
// Check quality and status
if (output.getStatus() == ControllerDataExchange.ExecutionStatus.SUCCESS) {
applyMVs(output.getMvTargets());
}
}
Quality Flags:
GOOD- Valid measurementBAD- Invalid/failed measurementUNCERTAIN- Quality questionableMANUAL- Manually entered valueCLAMPED- Value at limit
Execution Status:
READY- Controller ready for executionSUCCESS- Execution completed successfullyWARNING- Completed with warningsFAILED- Execution failedMODEL_STALE- Model needs update
Soft Sensor Export
Export soft-sensor configurations for industrial calculation engines:
SoftSensorExporter softExporter = new SoftSensorExporter(process);
softExporter.setTagPrefix("UNIT1");
softExporter.setApplicationName("GasProcessing");
// Add sensors for thermodynamic properties
softExporter.addDensitySensor("sep_gas_density", "separator", "gas outlet");
softExporter.addViscositySensor("sep_oil_visc", "separator", "oil outlet");
softExporter.addPhaseFractionSensor("sep_gas_frac", "separator");
softExporter.addCompositionEstimator("sep_comp", "separator", "gas outlet",
new String[]{"methane", "ethane", "propane"});
// Export in JSON and CVT formats
softExporter.exportConfiguration("soft_sensors.json");
softExporter.exportCVTFormat("soft_sensors.cvt");
Nonlinear MPC with State Variables
For nonlinear MPC systems that use programmed model objects:
// Create MPC with state variables
ProcessLinkedMPC mpc = new ProcessLinkedMPC("wellController", process);
mpc.addMV("choke", "opening", 0.0, 1.0);
mpc.addCV("well", "pressure", 50.0);
mpc.addDV("reservoir", "pressure");
// Add state variables (SVR) for internal model states
StateVariable flowIn = mpc.addSVR("well", "flowIn", "qin");
StateVariable flowOut = mpc.addSVR("well", "flowOut", "qout");
mpc.addSVR("choke", "cv", "cv");
// Configure bias handling for state estimation
flowIn.setBiasTfilt(30.0); // 30 second filter on bias
flowIn.setBiasTpred(120.0); // 2 minute prediction decay
// Export for nonlinear MPC system
SubrModlExporter exporter = mpc.createSubrModlExporter();
exporter.setModelName("WellModel");
exporter.addParameter("Volume", 100.0, "m3");
exporter.addParameter("Height", 2000.0, "m");
exporter.addParameter("Density", 700.0, "kg/m3");
exporter.addParameter("Compressibility", 500.0, "bar");
exporter.addParameter("ProductionIndex", 8.0, "m3/h/bar");
// Export configuration files
exporter.exportConfiguration("well_config.txt");
exporter.exportMPCConfiguration("mpc_config.txt", true); // true = SQP solver
exporter.exportIndexTable("well_ixid.cpp");
exporter.exportJSON("well_model.json");
Generated Configuration Example:
WellModelProc: NonlinearSQP
Volume= 100
Height= 2000
Density= 700
Compressibility= 500
ProductionIndex= 8
SubrXvr: Pdownhole
Text1= "Downhole pressure"
Text2= ""
DtaIx= "pdh"
Init= 147.7
SubrXvr: Pwellhead
Text1= "Wellhead pressure"
Text2= ""
DtaIx= "pwh"
Init= 10.4
MPC Configuration Parameters:
| Parameter | Description | Typical Value |
|---|---|---|
| SteadySolver | Steady-state solver type | SQP or QP |
| IterOpt | Enable iterative optimization | ON/OFF |
| IterNewSens | Recalculate sensitivities each iteration | ON/OFF |
| IterQpMax | Maximum QP iterations | 10 |
| IterLineMax | Maximum line search iterations | 10 |
| LinErrorLim | Linearization error limit | 0.2 |
| MajItLim | Major iteration limit (SQP) | 200 |
| FuncPrec | Function precision | 1e-08 |
| FeTol | Constraint feasibility tolerance | 1e-03 |
| OptimTol | Optimality tolerance | 1e-05 |
Export versus injection with a scheduled takeaway reduction
The executable export/injection example routes 100 kg/h of methane through a NeqSim splitter. A local response model represents the effect of third-stage suction pressure on the split. At 48 bara, injection takes 20 kg/h. Raising suction by 1 bar diverts another 2 kg/h from export to injection. The assumed export-header pressure rises by 0.5 bar for each kg/h by which export exceeds the takeaway nomination. These synthetic gains describe this example only. A compressor application needs identified responses, valve limits and anti-surge protection appropriate to the equipment.
Every 15 s the controller predicts the next six minutes, optimizes four independent suction settings and holds the fourth setting for the rest of the horizon. It applies the first setting. Suction is limited to 48–54 bara and can move by 1 bar per scan. A preferred setting of 48 bara favours export. A soft upper limit of 100 bara on the header discourages routing more gas to export than the receiving system can take.
At 60 s, takeaway drops from 80 to 74 kg/h. With advance notice, the controller diverts some gas to injection before the change. The test checks the cost in diverted gas and compares the integrated pressure exceedance with a pressure-feedback controller subject to the same actuator limits. At 135 s an unexpected drop to 64 kg/h puts the measured header pressure 5 bar above the one-step forecast. Even at the suction upper limit, export is at least 68 kg/h, so the next scan must report at least 2 bar of upper slack. The test checks the measured export-plus-injection balance and the applied first move on every scan.
| Quantity in the synthetic replay | Preview MPC | Pressure feedback |
|---|---|---|
| Additional gas injected before the planned reduction, relative to feedback | 0.0215 kg | 0 kg |
| Integrated pressure above 100 bara during the five planned-reduction scans | 12.55 bar·s | 90.00 bar·s |
The first scan after detecting the surprise reports 4.143 bar of upper slack. The 1 bar-per-scan slew limit prevents the controller from immediately reaching the maximum suction pressure.
See Also
- ModelPredictiveController - Underlying MPC implementation
- ProcessSystem - NeqSim process simulation
- AI Platform Integration - Broader AI integration guide