Numerical health and engineering closure

EngineeringNumericalHealthAnalyzer converts solver state and engineering closure evidence into a deterministic, machine-readable report. It addresses a different question from whether a calculation executed: whether the numerical state is sufficiently complete and well behaved to enter a controlled engineering review.

The report contains:

Missing required evidence produces INCOMPLETE; a convergence, tolerance, or rank failure produces FAILED. Only a HEALTHY report returns isAcceptableForEngineering() == true. The report is evidence for engineering review, not an engineering approval.

Basic process check

EngineeringNumericalHealthReport report = EngineeringNumericalHealthAnalyzer.analyze(process);
if (!report.isAcceptableForEngineering()) {
  throw new IllegalStateException(report.getFindings().toString());
}

The default criteria require convergence and at least one applicable unit-operation mass balance. Boundary streams with zero reference inlet flow and zero imbalance are recorded as NOT_APPLICABLE, not silently counted as passing.

Controlled closure criteria

EngineeringNumericalHealthCriteria criteria = EngineeringNumericalHealthCriteria.builder()
    .maximumMassBalanceErrorPercent(0.05)
    .maximumEnergyBalanceErrorPercent(0.1)
    .requireEnergyClosure(true)
    .requireEquationResiduals(true)
    .requireSensitivityEvidence(true)
    .build();

double[][] jacobian = sensitivityAnalyzer.jacobian(outputs, "kW", inputs, "bara");
EngineeringNumericalHealthReport report = new EngineeringNumericalHealthAnalyzer(process, criteria)
    .addEnergyClosure("compression-train", energyImbalanceKw, energyThroughputKw, "kW")
    .addEquationResidual("recycle-flow", recycleResidual, 1.0e-6, "kg/sec")
    .sensitivityJacobian(jacobian)
    .analyze();

Energy evidence is supplied explicitly because NeqSim equipment does not yet expose one universal energy-balance API. The denominator is the positive energy-flow magnitude used to normalize the imbalance; the report rejects absent, non-finite, or zero reference magnitudes. A future common equipment energy interface can feed the same report without changing its schema.

The Jacobian coefficientScaleRatio is a screening diagnostic, not a matrix condition number. Rank deficiency or a ratio above the controlled limit blocks acceptance; final ill-conditioning decisions still require a suitable scaled/SVD analysis and engineering judgment.

Design cases and production readiness

Enable a report for every isolated design case:

EngineeringCaseRunOptions options = EngineeringCaseRunOptions.builder()
    .parallelism(2)
    .numericalHealthCriteria(criteria)
    .build();
EngineeringCaseRunReport cases = EngineeringCaseRunner.run(process, caseSet, options);

Each DesignCaseResult then serializes numericalHealth. Attach controlled reports to EngineeringProductionReadinessBasis.addNumericalHealthReport(...) to activate the optional NUMERICAL_HEALTH_AND_ENGINEERING_CLOSURE readiness gate. Once activated, every attached process state must be HEALTHY; qualification-plan output identifies each state that needs closure work.

Review checklist

  1. Set tolerances from the project numerical-method basis; do not inherit example values without review.
  2. Cover every governing steady-state, transient snapshot, and degraded case used by downstream calculations.
  3. Supply energy closure at the boundary used by the engineering decision.
  4. Include residuals from recycles, columns, controllers, and custom equations where relevant.
  5. Scale sensitivity inputs and outputs consistently before interpreting the Jacobian screen.
  6. Store the JSON report beside the exact model revision, case inputs, method versions, and approval record.