NeqSim can export a fluid as an OLGA .tab PVT property table and as an OLGA hydrate equilibrium curve, so an OLGA (or LedaFlow) case can use exactly the same thermodynamics as a NeqSim process model. This page covers which generator to use, what OLGA requires, and how to verify that the output actually loads.

Choosing a generator

Both current generators live in neqsim.thermodynamicoperations.propertygenerator and write the modern PVTTABLE keyword format.

Generator Writes Use for
OLGApropertyTableGeneratorKeywordFormat PHASE = TWO Any fluid without a free water phase: dry gas, gas condensate, oil, dense-phase CO2
OLGApropertyTableGeneratorWaterKeywordFormat PHASE = THREE Fluids where a separate aqueous phase matters: produced water, hydrate studies, MEG systems

The three-phase generator also accepts a fluid with no water component at all; it simply writes zero water content. Prefer the two-phase generator when there is no water, because a three-phase table is larger and slower to build.

The older OLGApropertyTableGenerator, OLGApropertyTableGeneratorWater, OLGApropertyTableGeneratorWaterEven and the two ...Students variants write legacy formats and are kept only for backwards compatibility.

Minimal example

SystemInterface fluid = new SystemSrkEos(273.15 + 40.0, 60.0);
fluid.addComponent("methane", 0.85);
fluid.addComponent("ethane", 0.06);
fluid.addComponent("propane", 0.03);
fluid.addComponent("n-pentane", 0.03);
fluid.addComponent("n-heptane", 0.03);
fluid.setMixingRule("classic");

OLGApropertyTableGeneratorKeywordFormat generator =
    new OLGApropertyTableGeneratorKeywordFormat(fluid);
generator.setFluidLabel("EXPORTGAS");
generator.setPressureRange(5.0, 215.0, 44);          // bara
generator.setTemperatureRange(253.15, 333.15, 33);   // K
generator.run();
generator.writeOLGAinpFile("exportgas.tab");

The OLGA case then refers to the table and the label:

FILES PVTFILE="exportgas.tab"
...
 BRANCH FLUID="EXPORTGAS"

setFluidLabel must match BRANCH FLUID= exactly. When it is not set the label defaults to NewFluid.

For a three-phase fluid, swap in the water generator and add a water component:

fluid.addComponent("water", 0.12);
fluid.setMultiPhaseCheck(true);

OLGApropertyTableGeneratorWaterKeywordFormat generator =
    new OLGApropertyTableGeneratorWaterKeywordFormat(fluid);

Configuring the table

The calculation has four stages, each configured on the generator before run():

  1. Fluid preparation - optional produced water is added to a copy of the feed.
  2. Grid construction - the pressure and temperature axes are built from a range or a list, optionally refined around the water-free phase envelope, and optionally given the standard state as a node.
  3. Node evaluation - a TP flash at every node; each phase present is resolved by type and its properties are written. Aqueous properties can come from the IAPWS reference equations and be corrected for salinity.
  4. Absent-phase fill and checks - nodes where a phase does not exist are filled, the standard ratios are calculated, and the quality report is built.

Both keyword generators share the grid, fill and report settings; the water settings exist only on the three-phase generator.

Setting Method Notes
Equidistant axes setPressureRange(min, max, n) (bara), setTemperatureRange(min, max, n) (K) Default construction
Explicit axes setPressures(double[]), setTemperatures(double[]) Sorted and de-duplicated; every combination is tabulated
Envelope refinement setEnvelopeRefinement(true, gridFactor) Range axes only; gridFactor 1-10, see below
Standard state on the grid setInsertStandardConditions(true) Off by default
Standard conditions setStandardConditions(T_K, P_bara) Default 288.15 K and 1.01325 bara; used for GOR, GLR, WC and standard densities
Absent-phase fill setMonotonicityCorrection(true) On by default; see Absent phases
Produced water setProducedWater(value, "watercut" / "mol/mol" / "mol%" / "wt%") Three-phase only; feed must be water free
Salinity setWaterSalinity(value, "mg/l" / "ppm" / "wt%" / "kg/kg") Three-phase only
Reference water equations setUseReferenceWaterProperties(true) Three-phase only; off by default
Fluid label setFluidLabel(label) Must equal the genkey BRANCH FLUID=
Table fluid getTableFluid() Feed including produced water, after run()
Checks and report getQualityReport(), writeTableReport(file) After run()

Not available: a fixed-format (non-keyword) table, emulsion viscosity models and GERG-2008 tables. Emulsion effects belong in the OLGA case (WATEROPTIONS).

A three-phase table for a wellstream with 30 % water cut and 35 000 mg/l salinity:

SystemInterface fluid = new SystemSrkCPAstatoil(273.15 + 40.0, 60.0);
fluid.addComponent("methane", 0.80);
fluid.addComponent("ethane", 0.06);
fluid.addComponent("propane", 0.04);
fluid.addComponent("n-heptane", 0.05);
fluid.addComponent("nC10", 0.05);
fluid.addComponent("water", 0.0);           // produced water is added by the generator
fluid.setMixingRule(10);
fluid.setMultiPhaseCheck(true);

OLGApropertyTableGeneratorWaterKeywordFormat generator =
    new OLGApropertyTableGeneratorWaterKeywordFormat(fluid);
generator.setFluidLabel("WELLSTREAM");
generator.setPressureRange(5.0, 250.0, 50);          // bara
generator.setTemperatureRange(253.15, 393.15, 50);   // K
generator.setEnvelopeRefinement(true, 5.0);
generator.setInsertStandardConditions(true);
generator.setProducedWater(30.0, "watercut");        // vol % of the standard liquid
generator.setWaterSalinity(35000.0, "mg/l");
generator.setUseReferenceWaterProperties(true);
generator.run();
generator.writeOLGAinpFile("wellstream.tab");
generator.writeTableReport("wellstream_table_report.md");
generator.getQualityReport().writeCsv("wellstream_table_qc.csv");

The feed passed to the constructor is not modified when produced water is added. The water component may be present with zero moles, as an E300 file read with added water has it; if it is absent the generator adds it and re-applies the mixing rule.

Produced water

Specification Meaning
watercut Volume % water of the total liquid (oil plus water) at standard conditions; solved iteratively by standard-condition flashes, with the aqueous density from the same water model as the table (reference equations, salinity). Requires oil at standard conditions
mol/mol Mol produced water per mol feed
mol% Mol % water of feed plus produced water
wt% Weight % water of feed plus produced water

Produced water is the total water, including water dissolved in the gas and oil. A feed that already contains water is rejected.

Reference water equations

setUseReferenceWaterProperties(true) takes the aqueous columns (ROWT, DROWTDP, DROWTDT, CPWT, HWT, SEWT, VISWT, TCWT) from neqsim.thermo.util.steam.LiquidWaterReference:

Property Reference
Density, its P and T derivatives, Cp, enthalpy, entropy IAPWS-IF97 Region 1 Gibbs function, evaluated as a liquid at any pressure
Viscosity IAPWS R12-08, without the critical enhancement
Thermal conductivity IAPWS R15-11, without the critical enhancement

The equations are applied where the aqueous phase is at least 95 wt% water and the state lies within 253.15-623.15 K and up to 1000 bara. States below 273.15 K or below the saturation pressure are metastable extrapolations (LiquidWaterReference.isMetastable()). Inhibitor-rich water (MEG, methanol) keeps the equation-of-state values, because a pure-water reference is wrong there; getReferenceWaterNodeCount() and getReferenceWaterSkippedNodeCount() report the split. Enthalpy and entropy are shifted to the equation-of-state reference at standard conditions, so the latent heat between water vapour in the gas and liquid water stays consistent. Interfacial tensions are not changed: gas-water tension depends strongly on the gas pressure and is not a pure-water property.

Salinity

setWaterSalinity corrects aqueous density, its pressure and temperature derivatives, and viscosity with the NaCl brine correlations of Batzle and Wang (1992), applied as brine/fresh-water ratios (neqsim.thermo.util.steam.BrineSalinityCorrection). The ratio approach keeps the accuracy of the underlying water model (equation of state or reference equations). Salinity does not change phase amounts or compositions, the standard water density includes it, and it cannot be combined with ionic components in the feed. A concentration in mg/l is converted to a mass fraction at standard conditions.

Grid construction

Envelope refinement. setEnvelopeRefinement(true, gridFactor) traces the phase envelope of the water-free feed. Along the pressure axis, if the cricondenbar lies inside the range, the share $f = \text{gridFactor}/(\text{gridFactor}+1)$ of the points is placed between the lowest envelope pressure (or the range minimum) and the cricondenbar, and the rest outside; the temperature axis does the same with the cricondentherm. Each part is equidistant. An axis whose envelope maximum lies outside the range stays equidistant. With gridFactor = 5 a 50-point axis gets 42 points inside the envelope. Use at least 50 points per axis so the outside part is not too coarse.

Standard state on the grid. setInsertStandardConditions(true) makes the standard pressure and temperature grid nodes when they lie inside the range, so OLGA reads the standard state without interpolation. A range axis is rebuilt with one point fewer and the standard value inserted, keeping the point count; an explicit axis gains one point. A standard value outside the range is not added.

Water-free critical point. CRITICALPRESSURE, CRITICALTEMPERATURE and the envelope used for refinement are taken from the water-free composition: water is removed when it is the last component and otherwise reduced to a trace. The water dew line of a wet feed would otherwise dominate the envelope and move the refined points away from the hydrocarbon two-phase region.

Quality report and table report

getQualityReport() returns an OlgaTableQualityReport after run():

Violations at existing nodes can be physical: a retrograde condensate liquid becomes lighter with pressure as gas dissolves. They are reported, not changed. Violations at extrapolated nodes indicate a fill defect.

writeTableReport(file) writes a Markdown engineering report with the fluid and composition, the grid and how each axis was built, standard ratios and densities, the water-free envelope, the water models with node counts, and the quality table. Attach it to the study next to the .tab file.

What OLGA requires of a table

These are the rules that actually cause OLGA to reject a file, in the order they tend to bite:

  1. No zero densities. OLGA aborts with ERROR IN THE INPUT FILE: OIL DENSITY IS ZERO AT: PRES.= ... AND TEMP. = ... if any ROG, ROHL or ROWT entry is zero. A flash only returns the phases that exist, so every node outside a phase’s existence region needs a value anyway - see Absent phases below.
  2. No NaN or Infinity. These are written literally by Java and OLGA cannot parse them.
  3. The grid must span the whole simulation. OLGA stops with PRESSURE ABOVE TABLE VALUES or TEMPERATURE BELOW TABLE VALUES the moment a section leaves the tabulated range. Size the grid against the expected solution, not the boundary conditions: a long line with Joule-Thomson cooling arrives far colder than its inlet.
  4. BUBBLEPRESSURES and BUBBLETEMPERATURES must describe matching saturation points. The three-phase generator omits these optional headers for multicomponent fluids: a bubble flash of a feed containing free water can follow an inappropriate liquid branch. For a pure component, it writes only validated subcritical pressure/temperature pairs. Failed points are omitted, never replaced by zero. If no valid pure-component point is available, writing fails explicitly; include subcritical temperatures in the grid.

Three-phase fractions and standard ratios

OLGApropertyTableGeneratorWaterKeywordFormat uses these definitions:

Keyword Definition
RS Gas mass divided by gas plus oil phase mass at the grid state; the separate aqueous phase is excluded
RSW Water mass fraction within the gas phase
GOR Standard gas volume divided by standard oil volume
GLR Standard gas volume divided by standard oil plus aqueous volume
WC Standard aqueous volume divided by standard oil plus aqueous volume, as a fraction from 0 to 1

The standard flash uses the written STDPRESSURE (1 atm by default) and STDTEMPERATURE (288.15 K by default; change both with setStandardConditions). Volumes are calculated from phase mass and physical density, including any volume correction. GOR is -999 when there is no standard oil, and GLR is -999 when there is no standard liquid. WC is zero when there is no standard liquid. A gas/water state with no oil has RS = 1; a state with no gas has RS = 0, including an aqueous-only state. These fractions are independent of the placeholder properties used for absent phases.

This corrects earlier three-phase exports that included aqueous mass in RS, copied GOR into GLR, omitted WC, and could write invalid bubble curves. Regenerate affected .tab files before reusing them in OLGA. The regression coverage checks the reported SRK-CPA wet-condensate case and standard-condition phase volumes; a full OLGA pipeline run remains a separate validation step.

Absent phases and how they are filled

A dry gas has no liquid anywhere, a dead oil has no gas, and a gas condensate has only one phase outside its two-phase envelope. OLGA still expects a full gas column and a full liquid column at every node.

The generators therefore:

  1. resolve phases by type (gas, oil, aqueous) rather than by array position, so the gas column stays gas even at a single-phase node;
  2. fill nodes where a phase is absent. With the monotonicity correction (the default), density is filled along pressure and enthalpy and entropy along temperature: a gap between two nodes where the phase exists is interpolated linearly, and nodes beyond the last existing node are extrapolated with the phase’s own gradient there (dRho/dP, Cp, Cp ln T). The filled branch is therefore monotonic, continuous at the phase boundary and consistent with the DRO*DP and CP* columns. Remaining columns, and grid lines without any existing node, use nearest-neighbour extrapolation in grid-index space. With setMonotonicityCorrection(false) every column uses the nearest neighbour, which holds enthalpy flat with temperature in the absent region;
  3. fall back to a forced single-phase evaluation of the whole composition when a phase exists nowhere on the grid, and to a documented physical default when even that has no usable root.

The extrapolated branch is never used in a flow calculation, because the corresponding phase mass fraction (RS, RSW) is zero there. It exists purely so the table loads. Mass fractions are not extrapolated - a zero gas fraction is physically correct and is written as zero.

Choosing the grid

Parameter Guidance
Pressure range From below the lowest arrival pressure to above the highest inlet pressure, with margin for the solver overshooting
Temperature range From below the coldest expected temperature (include JT cooling and seabed ambient) to above the hottest inlet
Resolution 30-50 pressures x 25-35 temperatures is usually enough; refine near the phase envelope with setEnvelopeRefinement(true, 5.0) rather than everywhere
Standard conditions setInsertStandardConditions(true) puts 1 atm and 15 C on the grid so OLGA interpolates the standard state exactly

Use an asymmetric grid when testing generator changes: a square grid hides index transposition bugs.

Validating a generated table

A rule check (Olga-<version>.exe -exitRC case.genkey) does not read the PVT file, so it proves nothing about the table. The only real test is to run a case that uses it. A minimal flowpath with a source, a pressure node and a short pipe is enough - if OLGA initialises and integrates, the table is loadable.

When benchmarking OLGA against NeqSim, also check that the two see the same fluid:

Hydrate curves

OLGA does not compute hydrate thermodynamics. It checks hydrate risk against a tabulated equilibrium curve, and its built-in alternative is the Hammerschmidt correlation - a crude inhibitor shift. Exporting the curve from NeqSim gives OLGA the same rigorous hydrate model the NeqSim side of a study uses, including a real MEG or methanol inhibited curve, so the two codes agree on where the hydrate boundary sits.

SystemInterface fluid = ...;                  // must contain water
OLGAhydrateCurveGenerator generator = new OLGAhydrateCurveGenerator(fluid);
generator.setCurveLabel("LINNORM_HYD");
generator.setPressureRange(10.0, 200.0, 12);  // bara
generator.run();
generator.writeOLGAinpFile("linnorm_hydrate_curve.inp");
System.out.println(generator.getHydrateCheckKeyword());

The generated block is a library-level keyword:

HYDRATECURVE LABEL = "LINNORM_HYD", \
             PRESSURE = (10.0000,27.2727,...) bara, \
             TEMPERATURE = (0.6871,8.9597,...) C

referenced from the flowpath by label - this line is what getHydrateCheckKeyword() returns:

NETWORKCOMPONENT TYPE=FLOWPATH, TAG=FLOWPATH_1
 ...
 HYDRATECHECK HYDRATECURVE="LINNORM_HYD"
ENDNETWORKCOMPONENT

Notes:

Report the margin in OLGA with the DTHYD profile variable (hydrate temperature minus section temperature); DPHYD is the pressure equivalent. On the Linnorm export line with 15 m3/hr of free water, OLGA’s hydrate temperature reproduced the 12-point NeqSim curve to within 0.012 K, the residual being OLGA’s own linear interpolation between the supplied points.

What cannot be generated from NeqSim

Feature OLGA input Can NeqSim supply it?
Hydrate curve HYDRATECURVE + HYDRATECHECK Yes - OLGAhydrateCurveGenerator
Hydrate kinetics HYDRATEKINETICS scalars (STRUCTURE, GASGUESTFRACTION, …) Partly - NeqSim’s hydrate flash gives structure sI/sII and guest occupancies as scalars
Wax deposition WAXDEPOSITION tuning keys, wax thermodynamics inside the PVT table Physics yes (PhaseWax, WAT, wax fraction), but the OLGA wax table column format is not implemented
Emulsion / inversion WATEROPTIONS scalars: INVERSIONWATERFRAC, WATERSLIP, ENTRAINMENTFACTOR, PHI100, EMAX No file to generate - these are case scalars. NeqSim can only supply calibration values

There is no WAXTABLE, WAXFILE or EMULSION keyword in OLGA 2025.1; both were checked against the rules engine.