Capacity Constraint Framework

Overview

The Capacity Constraint Framework extends NeqSim’s existing bottleneck analysis capability with multi-constraint support. It provides:

Setting limits through mechanical design: To derive capacity constraints directly from an equipment’s design envelope (max design pressure drop, volume flow, power, etc.), see Equipment Utilization via Mechanical Design.

Running the examples

The examples use the current Java API and Java 8 syntax. Put imports at the top of a source file, statement snippets in a method, and class definitions in their own source files (or as nested classes). Run each alternative example in a fresh scope. In addition to imports shown locally, the equipment examples use:

import java.util.*;
import org.apache.logging.log4j.LogManager;
import org.apache.logging.log4j.Logger;
import neqsim.process.equipment.ProcessEquipmentInterface;
import neqsim.process.equipment.capacity.*;
import neqsim.process.equipment.capacity.CapacityConstraint.ConstraintType;
import neqsim.process.equipment.compressor.Compressor;
import neqsim.process.equipment.expander.Expander;
import neqsim.process.equipment.heatexchanger.*;
import neqsim.process.equipment.manifold.Manifold;
import neqsim.process.equipment.pipeline.*;
import neqsim.process.equipment.pump.Pump;
import neqsim.process.equipment.separator.Separator;
import neqsim.process.equipment.stream.*;
import neqsim.process.processmodel.*;
import neqsim.process.util.optimizer.*;
import neqsim.process.util.optimizer.PressureBoundaryOptimizer.LiftCurveTable;
import neqsim.thermo.system.SystemSrkEos;

Use this feed when a snippet expects fluid or feed. Downstream snippets must use streams from their own solved process, not unrelated copies. Names such as compressor, separator, equipment, plant, and model refer to that explicitly configured model. The registry and immutable-evidence sections require the additional installed design data and exact calculation identity described in those sections (calculationId is a String).

Logger logger = LogManager.getLogger("CapacityExample");
SystemSrkEos fluid = new SystemSrkEos(298.15, 50.0);
fluid.addComponent("methane", 0.9);
fluid.addComponent("ethane", 0.1);
fluid.setMixingRule("classic");
Stream feed = new Stream("Feed", fluid);
feed.setFlowRate(10000.0, "kg/hr");
feed.run();

The executable regression coverage is in CapacityOptimizationDocumentationTest; the registry/snapshot API families also have their own dedicated tests. Missing installed ratings must remain explicit evidence gaps. Auto-sizing and default strategy limits are screening inputs, not vendor qualification.

Plant-wide constraint registration

PlantConstraintRegistry adds deterministic plant identity and engineering-basis metadata without replacing equipment-local CapacityConstraint calculations. It can register constraints on an equipment item, stream, area, complete model, shared resource, or coupled group such as compressors on a common shaft. Definitions are immutable, serializable, callback-free, and directly accessible from Python through JPype.

The registry deliberately does not calculate utilization or declare a process candidate feasible. It is the metadata layer consumed by the later complete-snapshot and solver layers.

Registration field Contract
Stable identity Escaped model, area, subject, and caller-owned constraint ID
Aggregation DIRECT, SUM, MAXIMUM, MINIMUM, SHARED_BUDGET, COMMON_SETPOINT, or explicit rate-basis conversion
Engineering basis Target unit, measurement/rating basis, provenance, owner, reference, and calculation method
Evidence quality Optional confidence and scalar validity interval
Status Registered, disabled, incomplete basis, or disabled with incomplete basis

Aggregated participants must use the target unit and basis. NeqSim never guesses a conversion; an unlike source must declare an explicit finite affine conversion. Aggregates also require a non-empty target unit and basis. This prevents, for example, silently adding shaft kW to electrical MW, or combining standard and actual volumetric rates.

PlantConstraintRegistry registry = new PlantConstraintRegistry();
PlantConstraintDefinition totalPower = PlantConstraintDefinition
    .builder("total-power", PlantConstraintScope.sharedResource("NorthPlant", "electrical-power"))
    .aggregationPolicy(PlantConstraintDefinition.AggregationPolicy.SHARED_BUDGET)
    .unit("MW")
    .basis("instantaneous electrical load")
    .provenance("site power study 2026")
    .participant(PlantConstraintParticipant.direct(
        "compression/K-101", "MW", "instantaneous electrical load"))
    .participant(PlantConstraintParticipant.converted(
        "compression/K-102", "kW", "instantaneous electrical load", 0.001, 0.0))
    .build();
registry.register(totalPower);

Use registerEquipmentConstraint(...) to copy identity-relevant metadata from an existing CapacityConstraint. The adapter does not invoke or retain its live value supplier. Runtime values, applicability, convergence, margins, and utilization belong in a complete immutable snapshot and must be regenerated after every process solve.

Complete immutable plant utilization snapshots

PlantUtilizationSnapshot is the post-solve evidence layer consumed by later plant-wide resource and solver increments. It pairs every deterministic registry definition with a callback-free PlantConstraintSample for one exact calculationId. The snapshot does not run equipment, evaluate constraints, aggregate shared resources, or mutate process state.

Each row separates evidence coverage from operating status. Disabled definitions remain visible and need no runtime sample. Enabled missing, stale, out-of-validity, non-finite, metadata-mismatched, calculation-ID-mismatched, exception, and incomplete-convergence rows remain explicit and make the snapshot incomplete. Finite available evidence retains:

Quantity Unit and sign contract
Sampled value and applicable limit Registered physical unit and basis
Normalized utilization Dimensionless; 1.0 is active
Normalized residual Dimensionless utilization - 1; positive violates
Physical margin Registered unit; positive is headroom and negative violates
Required relief Registered unit; non-negative amount required to reach the limit

isComplete() requires valid exact-calculation evidence for every enabled definition. Without an explicit expected-coverage report, this means registered constraints only; it cannot detect equipment or restrictions that were never registered. Use the coverage preflight below to connect declared engineering scope to the registry before accepting a snapshot. isFeasible() additionally rejects any hard or critical violation. Soft and advisory violations are ranked and reported but do not silently become hard constraints. The immutable bottleneck ladder contains all enabled available rows in descending utilization order with stable identity as the tie breaker.

Use PlantConstraintSample.fromInstalledEquipmentEvidence(...) and fromProcessBoundaryEvidence(...) to reuse existing immutable #2941 equipment evidence and process- boundary evidence. These adapters validate identity, direction, physical unit, and evidence status; they do not retain live suppliers or evaluator callbacks. A sample’s registered basis is copied from the matching plant definition, so an adapter cannot invent a rate- or reference-basis conversion.

Shared total-power evidence

PlantSharedResourceEvidence is the immutable post-solve adapter for a maximum SHARED_BUDGET. It requires one observation for every registered participant and an independently calculated total in the same target unit and basis. Missing, unexpected, stale, non-finite, out-of-validity, metadata-mismatched, exception, or unconverged evidence is incomplete; unavailable values are Java NaN and JSON null, never zero load.

Use fromProcessSystemShaftPower(...) when participant IDs are top-level compressor or pump names, or fromProcessModelShaftPower(...) when participant IDs are ProcessModel area names. Both adapters cross-check the participant sum against the existing getPower(unit) total and retain the explicit compressor and pump shaft-power basis. They do not infer motor efficiency or convert shaft power to electrical demand.

PlantConstraintDefinition shaftBudget = PlantConstraintDefinition
    .builder("total-shaft-power",
        PlantConstraintScope.sharedResource("NorthPlant", "compression shaft power"))
    .aggregationPolicy(PlantConstraintDefinition.AggregationPolicy.SHARED_BUDGET)
    .limitDirection(PlantConstraintDefinition.LimitDirection.MAXIMUM)
    .unit("MW")
    .basis("compressor and pump shaft power")
    .provenance("approved rotating-equipment study")
    .participant(PlantConstraintParticipant.converted(
        "Compression", "kW", "compressor and pump shaft power", 0.001, 0.0))
    .build();

PlantSharedResourceEvidence powerEvidence =
    PlantSharedResourceEvidence.fromProcessModelShaftPower(
        shaftBudget, calculationId, 12.0, model, model.isModelConverged(),
        "completed isolated ProcessModel");
PlantUtilizationSnapshot snapshot = PlantUtilizationSnapshot.builder(
        new PlantConstraintRegistry().register(shaftBudget), calculationId)
    .convergenceComplete(model.isModelConverged())
    .sample(powerEvidence.toPlantConstraintSample())
    .build();

For an electrical EnergyBus, fromSolvedEnergyBusRequestedDemand(...) uses the current solved report’s requested input demand, including unmet demand. It ignores producer output rows and rejects unregistered inputs, external demand, bidirectional loads, and stale reports. An out-of-service shaft participant is accepted only when explicitly named and observed at finite zero power. Changing a limit or line-up requires new evidence with a new calculation identity; collection is read-only and does not restore process mutations.

This layer is deliberately not operating authority. It does not infer electrical efficiency, compute separator capacity or piping hydraulics, coordinate product quality, emissions or utility allocation, restore mutations, cache process results, schedule dirty equipment, or accept solver candidates. External optimizer proposals must still be replayed and accepted by the full NeqSim model.

Common-shaft compressor-train evidence

PlantCommonShaftEvidence freezes the already solved MechanicalShaft allocation together with the declared CompressorDriver, Gearbox, and every casing Compressor operating point. The adapter performs no equipment run and retains no mutable equipment. The caller supplies the exact calculation ID, driver and casing participant IDs, speed and power-balance tolerances, and an independently approved maximum torque.

The resulting common snapshot contains distinct constraints for casing-to-shaft speed agreement, shaft maximum speed, unmet shaft power, driver speed range and available power, gearbox maximum input power, shaft maximum torque, and each casing’s minimum signed surge/stonewall map margin. Power is in kW, speed in rpm, torque in N m, and map distances are dimensionless. Gearbox input power uses the configured efficiency and idle loss; driver speed uses the configured output-to-input ratio; torque uses only power / angular speed. No rating or map envelope is inferred.

Every active shaft input and the driver output must be declared. A stale bus report, unexpected participant, mismatched calculation identity or casing power, chartless or non-finite map point, unknown rating, trip, or incomplete convergence makes the evidence incomplete. A finite solved point outside its map or beyond a declared speed, power, gearbox, or torque limit remains complete but infeasible. Explicitly out-of-service casings qualify only with verified zero requested and observed shaft load. Java getters, serialization, toPlantUtilizationSnapshot(), and toJson() expose the same immutable evidence; unavailable JSON numbers are null, never zero.

Strict separator evidence

PlantSeparatorEvidence adapts an already solved separator into the same immutable plant registry and snapshot model. Select GAS_SCRUBBER, TWO_PHASE_OIL, TWO_PHASE_WATER, or THREE_PHASE so the required phase observations are explicit. The adapter reads the existing Souders-Brown gas-load, K-value, droplet-cut, inlet-momentum, oil/water residence, live liquid-level, and three-phase interface-settling calculations. It does not run or retain the separator.

The strict path requires the exact completed calculation ID, full-candidate convergence, vessel diameter and length, inlet-nozzle diameter, and every applicable HLL/NLL/NIL and effective-length input. This intentionally disables the convenience geometry fallbacks used by interactive separator calculations: missing design data becomes unavailable evidence, never zero utilization. The liquid-level and three-phase interface-settling limits are caller-owned installed limits.

PlantSeparatorEvidence separatorEvidence = PlantSeparatorEvidence
    .builder("Plant", "Separation", calculationId, separator,
        PlantSeparatorEvidence.Profile.THREE_PHASE,
        "approved vessel rating revision 4")
    .maximumLiquidLevelFraction(0.80)
    .minimumInterfaceSettlingMinutes(1.0)
    .convergenceComplete(model.isModelConverged())
    .build();

if (!separatorEvidence.isComplete()) {
  throw new IllegalStateException(separatorEvidence.getDiagnostics().toString());
}
PlantUtilizationSnapshot separatorSnapshot =
    separatorEvidence.toPlantUtilizationSnapshot();

Java serialization, JPype getters, toPlantUtilizationSnapshot(), and toJson() preserve the same detached values, physical margins, units, bases, and diagnostics. A physical limit violation remains complete and is interpreted according to the severity of the corresponding installed separator constraint. Carry-over/carry-under and slug handling are not inferred: they remain separate required coverage until a qualified provider, measured correlation, or installed slug-volume rating is declared and validated.

Strict piping evidence

PlantPipelineEvidence snapshots one completed PipeBeggsAndBrills calculation into six deterministic hydraulic/thermal rows: maximum absolute pressure, total pressure drop, receiving pressure, maximum mixture superficial velocity, and minimum/maximum bulk-fluid temperature. Each row retains the governing solved-profile node and distance from the inlet.

The caller must explicitly declare every installed limit and confirm that length, diameter, and roughness came from the stated line-list or design source. The adapter never treats the pipe’s constructor defaults, auto-sizing values, API RP 14E result, FIV/FRMS/AIV screening result, or a missing rating as installed capacity.

PlantPipelineEvidence pipelineEvidence = PlantPipelineEvidence
    .builder("Plant", "Gathering", calculationId, pipeline,
        "approved line list revision 7 and operating case")
    .geometryVerified(true)
    .maximumPressureBara(120.0)
    .maximumPressureDropBar(12.0)
    .minimumReceivingPressureBara(70.0)
    .maximumMixtureVelocityMetresPerSecond(14.0)
    .minimumTemperatureCelsius(-20.0)
    .maximumTemperatureCelsius(80.0)
    .convergenceComplete(model.isModelConverged())
    .build();

if (!pipelineEvidence.isComplete() || !pipelineEvidence.isFeasible()) {
  throw new IllegalStateException(pipelineEvidence.getDiagnostics().toString());
}
PlantUtilizationSnapshot pipelineSnapshot =
    pipelineEvidence.toPlantUtilizationSnapshot();

Exact pipe and candidate calculation identity, a complete solved profile, monotonic profile distance, finite values, and complete convergence are mandatory. Isothermal calculations carry the single authoritative temperature observation returned by the pipe; non-isothermal calculations retain the actual temperature extrema. Java getters, serialization, JPype use, and toJson() expose the same callback-free values and physical margins. Hydrate/wax/liquid-dropout envelopes, noise/FIV qualification, erosion acceptance, slugging, transient integrity, and pipeline-solver changes remain separately owned and must be registered only from qualified evidence.

Expected equipment coverage before qualification

UtilizationCoverageReport captures evidence for explicitly declared equipment and constraint identities. It preserves expected-but-missing equipment, expected-but-missing constraints, and discovered constraints missing from the supplied PlantConstraintRegistry. A report with no declared equipment is incomplete. Completion applies to DECLARED_EQUIPMENT_AND_CONSTRAINTS; the caller remains responsible for choosing the engineering scope.

EquipmentCapacityConstraintResolver combines direct equipment definitions with the selected capacity strategy. Direct definitions take precedence per constraint name; they do not suppress unrelated strategy constraints. A disabled or incomplete direct override remains authoritative for its name. Discovery is deterministic and does not invoke value suppliers; report capture samples each selected enabled supplier once and retains only immutable values.

Evidence gap Coverage result
Missing equipment, constraint, or registration Explicit incomplete row or diagnostic
Unset current value, missing rating, non-finite result, or supplier exception Incomplete; unavailable numbers are Java NaN and JSON null
Missing unit, measurement/rating basis, or provenance Incomplete; no inferred unit or basis
Default fallback or advisory/design-only constraint SCREENING_ONLY; cannot qualify installed rated capacity
Registry unit, direction, severity, enablement, explicit basis, or supplied provenance differs METADATA_MISMATCH
Sample outside the source or registry validity range OUTSIDE_VALIDITY_RANGE
Intentionally disabled equipment or constraint Retained as DISABLED; its supplier is not sampled

For example, after obtaining the configured equipment object named K-101, register its installed power evidence and declare the required identity:

CapacityConstraint power = new CapacityConstraint("power", "kW", CapacityConstraint.ConstraintType.HARD)
    .setDesignValue(1000.0).setCurrentValue(750.0)
    .setDataSource("vendor datasheet revision 3");
equipment.addCapacityConstraint(power);
PlantConstraintRegistry registry = new PlantConstraintRegistry();
registry.registerEquipmentConstraint("NorthPlant", "Compression", "K-101", "power", "shaft power",
    PlantConstraintDefinition.Category.DESIGN, "rotating equipment", "K-101 datasheet", power);

UtilizationCoverageReport coverage = UtilizationCoverageReport.builder("NorthPlant")
    .expectConstraint("Compression", "K-101", "power")
    .equipment("Compression", equipment).registry(registry).build();

This example uses an explicitly supplied operating-point value. In a live process, use the equipment’s actual value supplier after the relevant process calculation. Inspect isComplete(), getDiagnostics(), getRequiredConstraintIds(), and getRows() from Java or JPype; toJson() exposes the same frozen evidence with null numeric gaps. With only the shown power constraint, the example reports utilization 0.75; any additional discovered constraint must also have complete registration and evidence. The example API chain is exercised by UtilizationCoverageReportTest.

Bind this registry-qualified report using PlantUtilizationSnapshot.Builder.expectedCoverage(coverage). The report must carry the matching registry digest. Snapshot qualification then also requires declared convergence and exact-calculation runtime evidence. Coverage preflight alone does not prove convergence, feasibility, complete process balances, shared-resource capacity, or operating approval. Rebuild the report after changing installed capacity inputs; it never updates itself from live state.

For preflight without a registry, use basis(areaName, equipmentName, constraintName, basis) to supply an explicit measurement basis. Such reports describe declared equipment evidence but cannot be used as registry-qualified snapshot coverage. Do not turn a default/advisory rating into installed capacity by adding a label: record and use the actual equipment or vendor rating.

CapacityConstraint.hasCurrentValue() distinguishes an unset legacy zero default from an explicit zero or available supplier, without sampling that supplier. getCurrentValue() retains its previous zero-default behavior. The new assignment flag survives Java serialization after explicit assignment or a successful sample. Old serialized constraints lack that flag and require reassignment or a reattached supplier before their cached values qualify as current evidence.

Important: Constraints Disabled by Default

Enablement is equipment-specific. Separator, valve, base Pipeline, pump, and manifold defaults commonly start disabled. PipeBeggsAndBrills velocity/FIV/AIV constraints start enabled; chartless compressors disable map-only metrics. Inspect the actual objects and enable the limits required by the study. The optimizer can use fallback rules when no constraints are enabled.

Why Constraints Are Disabled by Default

To maintain backward compatibility with existing simulations, constraints are created but not enabled when equipment is initialized. This ensures that:

  1. Existing code works unchanged - Simulations that don’t use capacity analysis continue to work
  2. Explicit opt-in for capacity analysis - You must explicitly enable constraints to use them
  3. No unexpected optimization failures - Optimizer falls back to traditional methods if no constraints are enabled

How to Enable Constraints

// Method 1: Use pre-configured constraint sets (Separator example)
Separator separator = new Separator("HP Separator", feed);
separator.useEquinorConstraints();  // Enables K-value, droplet, momentum, retention times
// OR
separator.useAPIConstraints();      // Enables K-value and retention times per API 12J
// OR
separator.useAllConstraints();      // Enables all 5 constraint types

// Method 2: Enable individual constraints
separator.getCapacityConstraints().get(StandardConstraintType.SEPARATOR_K_VALUE.getName())
    .setEnabled(true);

// Method 3: Enable all constraints at once
separator.enableAllConstraints();      // Enables all constraints on this equipment

// Method 4: Disable constraints (return to default)
separator.disableConstraints();     // Disables all constraints

How to Disable Constraints for What-If Analysis

For what-if scenarios or focused analysis, you can disable constraints at multiple levels:

// Method 1: Disable a specific constraint
Map<String, CapacityConstraint> constraints = separator.getCapacityConstraints();
constraints.get("gasLoadFactor").setEnabled(false);  // Disable one constraint
constraints.get("gasLoadFactor").setEnabled(true);   // Re-enable

// Method 2: Disable all constraints on a single equipment
int disabled = separator.disableAllConstraints();  // Returns count of disabled constraints
int enabled = separator.enableAllConstraints();    // Re-enable all

// Method 3: Disable all constraints across entire ProcessSystem
int total = processSystem.disableAllConstraints();  // All equipment, all constraints
processSystem.enableAllConstraints();               // Re-enable all

// Method 4: Disable all constraints across ProcessModule
for (ProcessSystem system : processModule.getAllProcessSystems()) {
    system.disableAllConstraints();
    system.enableAllConstraints();
}

// Method 5: FULLY exclude equipment from optimization (not just disable constraints)
separator.setCapacityAnalysisEnabled(false);  // Completely excluded from capacity analysis
separator.setCapacityAnalysisEnabled(true);   // Re-include

Comparison of Disable Methods:

Method Scope Effect on Optimization
constraint.setEnabled(false) One constraint Uses other constraints or fallback rules
equipment.disableAllConstraints() All constraints on equipment Falls back to type-specific capacity rules
processSystem.disableAllConstraints() All equipment in system All use fallback capacity rules
equipment.setCapacityAnalysisEnabled(false) Equipment level Fully excluded from optimization

How the Optimizer Uses Constraints

The ProductionOptimizer uses a multi-level decision process:

// Inspect the same enablement inputs used by the optimizer.
boolean included = !(equipment instanceof neqsim.process.equipment.ProcessEquipmentBaseClass)
    || ((neqsim.process.equipment.ProcessEquipmentBaseClass) equipment).isCapacityAnalysisEnabled();
boolean hasEnabledConstraints = equipment.getCapacityConstraints().values().stream()
    .anyMatch(CapacityConstraint::isEnabled);
logger.info("{}: included={}, enabled constraints={}", equipment.getName(),
    included, hasEnabledConstraints);

Key behavior:

Summary: Constraint Enablement by Equipment Type

Equipment Type Default State How to Enable
Separator All disabled useEquinorConstraints(), useAPIConstraints(), enableAllConstraints()
ThreePhaseSeparator All disabled Same as Separator
GasScrubber K-value only enabled useGasScrubberConstraints() (automatic in constructor)
Compressor All enabled (constraints created by autoSize() are enabled by default)
ThrottlingValve All disabled enableAllConstraints()
Pipeline (base) Disabled defaults enableAllConstraints()
PipeBeggsAndBrills Velocity/FIV/AIV enabled Inspect/set relevant limits
Pump All disabled enableAllConstraints()
Manifold All disabled enableAllConstraints()

Relationship to Existing Bottleneck Analysis

NeqSim already provides bottleneck analysis via ProcessEquipmentInterface:

Existing Method Description
getCapacityDuty() Current operating load (power, flow, etc.)
getCapacityMax() Maximum design capacity
getRestCapacity() Available headroom
ProcessSystem.getBottleneck() Equipment with highest utilization

The new CapacityConstrainedEquipment interface extends this by allowing:

The systems are integrated: ProcessSystem.getBottleneck() automatically uses multi-constraint data when available, falling back to single-capacity metrics for equipment that doesn’t implement the new interface.

Architecture

The framework integrates with existing bottleneck analysis in neqsim.process.equipment.capacity:

┌─────────────────────────────────────────────────────────────────────┐
│                         ProcessModule                                │
│  ┌────────────────────────────────────────────────────────────────┐ │
│  │  getConstrainedEquipment() │ findBottleneck() │ ...            │ │
│  │  (recursively searches all nested modules and systems)         │ │
│  └────────────────────────────────────────────────────────────────┘ │
│                              │                                       │
│         ┌────────────────────┴────────────────────┐                  │
│         ▼                                         ▼                  │
│  ┌──────────────────────┐             ┌──────────────────────┐       │
│  │    ProcessModule     │             │    ProcessSystem     │       │
│  │    (nested)          │             │                      │       │
│  └──────────────────────┘             └──────────────────────┘       │
└─────────────────────────────────────────────────────────────────────┘

┌─────────────────────────────────────────────────────────────────────┐
│                         ProcessSystem                                │
│  ┌───────────────────────────────────────────────────────────────┐  │
│  │  getBottleneck()  │  findBottleneck()  │  getRestCapacity()   │  │
│  │  (unified: checks both single and multi-constraint equipment) │  │
│  └───────────────────────────────────────────────────────────────┘  │
│                              │                                       │
│         ┌────────────────────┴────────────────────┐                  │
│         ▼                                         ▼                  │
│  ┌──────────────────────┐             ┌─────────────────────────────┐│
│  │  Traditional API     │             │  Multi-Constraint API       ││
│  │  getCapacityDuty()   │             │  CapacityConstrainedEquipment│
│  │  getCapacityMax()    │             │  ├─ getCapacityConstraints()││
│  │  getRestCapacity()   │             │  ├─ getBottleneckConstraint()│
│  └──────────────────────┘             │  └─ getMaxUtilization()     ││
│                                       └─────────────────────────────┘│
│                                                   │                  │
│                                                   ▼                  │
│  ┌─────────────────────────────────────────────────────────────────┐│
│  │                    CapacityConstraint                            ││
│  │  ┌──────────────────────────────────────────────────────────┐   ││
│  │  │ name │ type │ designValue │ maxValue │ valueSupplier │...│   ││
│  │  └──────────────────────────────────────────────────────────┘   ││
│  └─────────────────────────────────────────────────────────────────┘│
└─────────────────────────────────────────────────────────────────────┘

Core Classes

1. CapacityConstraint

The fundamental building block representing a single capacity limit on equipment.

import neqsim.process.equipment.capacity.CapacityConstraint;
import neqsim.process.equipment.capacity.CapacityConstraint.ConstraintType;

// Create a constraint with fluent builder pattern
CapacityConstraint speedConstraint = new CapacityConstraint("speed", "RPM", ConstraintType.HARD)
    .setDesignValue(10000.0)           // Design operating point (RPM)
    .setMaxValue(11000.0)              // Absolute maximum (trip point)
    .setMinValue(5000.0)               // Minimum stable operation
    .setValueSupplier(() -> compressor.getSpeed());  // Live value getter

Constraint Types

Type Description Example
HARD Absolute limit - equipment trip or damage if exceeded Compressor max speed, surge limit
SOFT Operational limit - reduced efficiency or accelerated wear High discharge temperature
DESIGN Normal operating limit - design basis Separator gas load factor

Key Methods

Method Returns Description
getCurrentValue() double Current value from the valueSupplier
getUtilization() double Current/design for maximum constraints; minimum/current for minimum constraints (1.0 = limit)
getUtilizationPercent() double Utilization as percentage
isViolated() boolean True if utilization > 1.0
isHardLimitExceeded() boolean True if a HARD maximum is exceeded or a HARD minimum is undershot
isNearLimit() boolean True if above warning threshold (default 90%)
getMargin() double Remaining normalized headroom (1.0 - utilization)
getConfidence() double Evidence-quality score in [0, 1], or NaN when unset
isCurrentValueWithinValidityRange() boolean Whether the current value is inside the explicitly assigned range

Minimum constraints: Set minValue and leave designValue unset. This makes utilization minimum/current, so safe values above the minimum remain below 100%. Setting the same value as both design and minimum changes the direction to current/design and is incorrect for minimum NPSH headroom, minimum stable flow, residence time, or similar limits. Required NPSH margin is service- and pump-specific; use vendor or applicable Hydraulic Institute design data instead of treating a generic screening default as an approved installed limit.

ProcessModelSimulationEvaluator.BottleneckStatus and ThroughputCaseRow preserve this direction with isMinimumConstraint(). Their reported design value is the applicable finite limit. The engineering-unit capacity margin is positive on the feasible side: limit - current for maximum constraints and current - limit for minimum constraints. This convention prevents a minimum-only constraint’s internal unset design sentinel from appearing in JSON or CSV throughput results.

The same throughput rows preserve CapacityConstraint.getDataSource() as dataSource in Java, JSON, and CSV. Set a concise provenance tag such as mechanicalDesign, installedDataSheet, or operatingEnvelope when defining the limit. Untagged and legacy rows report not_set; downstream optimizers should retain this tag with recommendations rather than treating all limits as equally authoritative.

Confidence and validity metadata

Use confidence and validity metadata to state how strongly the limit is supported and where its basis applies:

CapacityConstraint gasCapacity = new CapacityConstraint("gasFlow", "kg/h", ConstraintType.HARD)
    .setDesignValue(12000.0)
    .setCurrentValue(10000.0)
    .setDataSource("installedDataSheet")
    .setConfidence(0.95)
    .setValidityRange(8000.0, 12000.0);

if (!gasCapacity.hasValidityRange()
    || !gasCapacity.isCurrentValueWithinValidityRange()) {
  // Require engineering review before relying on this limit outside its evidence range.
}

confidence is an evidence-quality score from zero to one. It is not a probability of safe operation, constraint satisfaction, or model accuracy. The validity bounds are inclusive, finite, and use the constraint’s own unit. An unset confidence or range remains explicitly distinguishable through hasConfidence() and hasValidityRange(); the numeric getters return NaN when unset. Invalid scores, non-finite bounds, and reversed ranges fail fast.

When the constraint becomes the active full-model bottleneck, ProcessModelSimulationEvaluator.BottleneckStatus and ThroughputCaseRow preserve the same confidence, validity bounds, and snapshotted in-range result. Java callers can use hasConfidence(), getConfidence(), hasValidityRange(), getValidityMinimum(), getValidityMaximum(), and isCurrentValueWithinValidityRange(). JSON rows include the hasConfidence and hasValidityRange flags; unset numeric or applicability values are null. CSV traces include the same flags and leave unset confidence, bounds, and applicability cells blank. Public snapshot constructors also normalize inconsistent enabled metadata (non-finite confidence or bounds, confidence outside [0, 1], or reversed bounds) to this unset state. Applicability is derived from each snapshot’s current value and retained bounds rather than accepted as caller-provided state. Dynamic value suppliers are read once per bottleneck candidate, and that same scalar is used for utilization and applicability. This prevents legacy, malformed, or unqualified limits from being mistaken for zero-confidence or out-of-range evidence.

This first validity contract is deliberately scalar. Compressor maps and other models whose applicability depends on several variables still require a separate multidimensional operating envelope. Confidence and validity metadata do not change utilization, feasibility, or optimizer behavior by themselves; downstream ranking must preserve and assess them explicitly.

For full-model diagnostics, ProcessModelSimulationEvaluator.rankCapacityConstraints(model) returns an immutable list of every enabled capacity constraint in descending utilization order. Equal-utilization constraints retain process-model registration order, including the declared order of built-in strategy-generated constraints. Each BottleneckStatus.getEvidenceApplicability() value is one of WITHIN_VALIDITY_RANGE, OUTSIDE_VALIDITY_RANGE, or NOT_ASSESSED. This makes unsupported and extrapolated limits visible beside the engineering ranking without allowing confidence or applicability to change utilization, feasibility, or order. The method snapshots every dynamic value supplier exactly once; enabled constraints with undefined (NaN) utilization remain visible at the end of the ranking; findActiveBottleneck(model) remains the lower-allocation API when only the leading constraint is needed.

After ProcessModelSimulationEvaluator.evaluate(...), use EvaluationResult.getRankedCapacityConstraints() instead of rescanning the live model. The result owns an immutable snapshot tied to that exact operating point, and its legacy active bottleneck is the first finite-utilization item in the same ranking. ProcessModelThroughputOptimizer copies the snapshot into each ThroughputCaseRow; JSON case tables therefore preserve near-active limits and bottleneck switching across the throughput search. The flat CSV remains a one-row-per-case summary of the leading limit; use JSON or the Java/JPype list when the complete per-case ranking is needed.

2. CapacityConstrainedEquipment (Interface)

Interface that equipment classes implement to participate in capacity tracking.

public interface CapacityConstrainedEquipment {
    // Get all constraints
    Map<String, CapacityConstraint> getCapacityConstraints();

    // Get the most limiting constraint
    CapacityConstraint getBottleneckConstraint();

    // Check constraint status
    boolean isCapacityExceeded();
    boolean isHardLimitExceeded();
    boolean isNearCapacityLimit();

    // Get utilization metrics
    double getMaxUtilization();
    double getMaxUtilizationPercent();
    double getAvailableMargin();

    // Modify constraints
    void addCapacityConstraint(CapacityConstraint constraint);
    boolean removeCapacityConstraint(String constraintName);
    void clearCapacityConstraints();
}

3. StandardConstraintType (Enum)

Predefined constraint types for common equipment with standardized names and units.

import neqsim.process.equipment.capacity.StandardConstraintType;

CapacityConstraint speed = StandardConstraintType.COMPRESSOR_SPEED.createConstraint()
    .setDesignValue(10000.0)
    .setCurrentValue(9000.0);
CapacityConstraint npsh = StandardConstraintType.PUMP_NPSH_MARGIN.createConstraint()
    .setMinValue(1.0)
    .setCurrentValue(2.0);
logger.info("Speed utilization: {}%, NPSH utilization: {}%",
    speed.getUtilizationPercent(), npsh.getUtilizationPercent());

4. BottleneckResult

Result class returned by ProcessSystem.findBottleneck().

BottleneckResult result = process.findBottleneck();

if (result.hasBottleneck()) {
    logger.info("Bottleneck: " + result.getEquipmentName());
    logger.info("Constraint: " + result.getConstraint().getName());
    logger.info("Utilization: " + result.getUtilizationPercent() + "%");
}

Adding & Configuring Custom Constraints

There are three ways to give an equipment new constraint functionality, ordered from the quickest (runtime, no subclassing) to the most reusable (built into an equipment type). All three produce ordinary CapacityConstraint objects, so they surface identically in getMaxUtilization(), getBottleneckConstraint(), findBottleneck(), and the utilization snapshot.

The constraint anatomy (what you configure)

Every constraint is built with the fluent CapacityConstraint API. The two constructors are:

new CapacityConstraint("name", "unit", ConstraintType.HARD);  // explicit unit + type
new CapacityConstraint("name");                                // defaults: unit "", type SOFT

Configurable properties (all are optional fluent setters returning this):

Setter Purpose Default
setDesignValue(double) Limit used for utilization = current / design required
setValueSupplier(DoubleSupplier) Live current value, re-evaluated each query none
setCurrentValue(double) Static current value (use when there is no live source) Legacy zero; hasCurrentValue() is false until assigned
setMaxValue(double) Absolute trip point for HARD constraints none
setMinValue(double) Minimum stable operating point none
setWarningThreshold(double) Near-limit early warning (fraction, e.g. 0.9) 0.9
setUnit(String) Unit label (when the 1-arg constructor was used) ””
setDescription(String) Human-readable description ””
setDataSource(String) Provenance tag (e.g. "mechanicalDesign", "user") “not_set”
setEnabled(boolean) Whether the optimizer/analysis counts it true

Live vs. static value: prefer setValueSupplier(...) so the constraint tracks the simulation. A manually built constraint is enabled by default, so it counts as soon as you add it (equipment defaults vary; strategy constraints are not universally disabled).

Level 1 — Add a custom constraint to one equipment instance (no subclassing)

The fastest path: build a constraint with a live supplier and register it on the equipment. Use this for one-off or study-specific limits.

// Example: cap a heater on its outlet temperature
Heater heater = new Heater("H-100", feed);
heater.setOutTemperature(100.0, "C");
heater.run();

CapacityConstraint tempLimit =
    new CapacityConstraint("outletTemperature", "C", ConstraintType.SOFT)
        .setDesignValue(120.0)                                  // design limit
        .setWarningThreshold(0.9)                               // warn at 90%
        .setDescription("Illustrative maximum process outlet temperature")
        .setValueSupplier(() -> heater.getOutletStream()
            .getTemperature("C"));                              // live value

heater.addCapacityConstraint(tempLimit);                        // active immediately
double util = heater.getMaxUtilization();                       // includes the new limit

Reconfigure or remove it at any time:

heater.getCapacityConstraints().get("outletTemperature").setDesignValue(110.0);
heater.getCapacityConstraints().get("outletTemperature").setEnabled(false); // what-if
heater.removeCapacityConstraint("outletTemperature");                       // remove

Level 2 — Give an equipment type built-in default constraints (subclass)

To make a constraint part of every instance of an equipment type, override the initializeDefaultConstraints() hook on ProcessEquipmentBaseClass. It is called lazily the first time constraints are accessed (and after deserialization), so it is the right place to register type-specific constraints.

public class RatedStream extends Stream {
  private static final long serialVersionUID = 1L;

  public RatedStream(String name, StreamInterface source) {
    super(name, source);
  }

  @Override
  protected void initializeDefaultConstraints() {
    addCapacityConstraint(new CapacityConstraint("installedMassFlow", "kg/hr",
        ConstraintType.HARD)
        .setDesignValue(12000.0)
        .setDataSource("illustrative installed throughput rating")
        .setValueSupplier(() -> getFlowRate("kg/hr")));
  }
}

Follow the framework convention: if your equipment should preserve backward compatibility, create the constraints disabled (setEnabled(false)) and provide a useXxxConstraints() / enableAllConstraints() method so users opt in (see how Separator exposes useEquinorConstraints()).

Level 3 — Derive constraints from the mechanical-design envelope

When the limit is a property of the equipment’s design envelope (max design power, flow, pressure drop, velocity, Cv, duty), configure it on the MechanicalDesign and let the bridge build the constraint for you. No CapacityConstraint object is needed. To support a new design-derived metric, override the matching protected getOperating* hook on a MechanicalDesign subclass. This path is documented in full in Equipment Utilization via Mechanical Design:

equipment.getMechanicalDesign().setMaxDesignPower(6000.0);     // kW
equipment.applyMechanicalDesignCapacityConstraints();          // opt-in bridge
double util = equipment.getMaxUtilization();                   // now includes design power

Plant-wide one-call activation

After auto-sizing a whole flowsheet, you do not need to loop over every unit. ProcessSystem and ProcessModel both expose a bulk helper that calls applyMechanicalDesignCapacityConstraints() on every contained piece of equipment and returns the number of units that registered at least one design-derived constraint. The call is idempotent (constraints use stable names) and safe to re-run after re-sizing:

plant.autoSizeEquipment(1.20);                 // size every unit with a 20% margin
int n = plant.applyMechanicalDesignCapacityConstraints();   // activate utilization plant-wide
// n == number of units that now expose design-envelope constraints
String snapshot = plant.getUtilizationSnapshotJson();        // side-effect-free read

For a multi-area ProcessModel the same method walks every area’s ProcessSystem, so a single call activates utilization tracking across the entire plant.

Which level should I use?

Need Use
A one-off limit for a single run/study Level 1 (instance addCapacityConstraint)
A limit that every instance of a new equipment type should have Level 2 (initializeDefaultConstraints)
A limit that is part of the design envelope (power, flow, dP, velocity, Cv, duty) Level 3 (mechanical design + bridge)

Integration with AutoSizing and Mechanical Design

How AutoSizing Creates Constraints

Run the feed and each upstream unit before sizing downstream equipment. Auto-sizing creates equipment-specific limits; enable the applicable constraints and inspect their values before optimizing. It does not qualify missing installed data.

// Auto-sizing creates constraints automatically
Separator sep = new Separator("HP-Sep", feed);
sep.run();
sep.autoSize(1.2);  // 20% safety factor

// This creates the following constraints:
// - gasLoadFactor: based on K-factor sizing calculation
// - oilRetentionTime/waterRetentionTime: minimum phase retention times

// For compressors, autoSize does even more:
Compressor comp = new Compressor("Export", sep.getGasOutStream());
comp.setOutletPressure(100.0);
comp.run();
comp.autoSize(1.2);

// This creates:
// - speed constraint (from mechanical design)
// - power constraint (from driver sizing)
// - surgeMargin constraint (soft limit)
// AND generates compressor curves, sets solveSpeed=true

Mechanical Design as Source of Constraint Values

The MechanicalDesign class provides design values that become constraint limits:

// Mechanical design values feed constraints
Separator sep = new Separator("V-100", feed);
sep.initMechanicalDesign();
SeparatorMechanicalDesign mechDesign = (SeparatorMechanicalDesign) sep.getMechanicalDesign();

// Set design limits that will become constraints
mechDesign.setMaxDesignVolumeFlow(5000.0);     // m³/hr
mechDesign.setMaxDesignPressureDrop(2.0);      // bara → pressureDrop constraint

// For pipelines
PipeBeggsAndBrills pipe = new PipeBeggsAndBrills("L-100", feed);
pipe.initMechanicalDesign();
PipelineMechanicalDesign pipeDesign = (PipelineMechanicalDesign) pipe.getMechanicalDesign();

// Design values → constraints
pipeDesign.setMaxDesignVelocity(15.0);           // → velocity constraint
pipeDesign.setMaxDesignPressureDrop(5.0);        // → pressureDrop constraint
pipeDesign.setMaxDesignVolumeFlow(10000.0);      // → volumeFlow constraint

Complete Workflow: Design → Constraints → Optimization

// 1. Create process; solve before auto-sizing
ProcessSystem process = new ProcessSystem();

Stream feed = new Stream("Feed", fluid);
feed.setFlowRate(10000.0, "kg/hr");
process.add(feed);

Separator sep = new Separator("HP-Sep", feed);
process.add(sep);

Compressor comp = new Compressor("K-100", sep.getGasOutStream());
comp.setOutletPressure(100.0);
comp.run();
process.add(comp);

PipeBeggsAndBrills pipe = new PipeBeggsAndBrills("Export", comp.getOutletStream());
pipe.setLength(30000.0);
pipe.setDiameter(0.3);
process.add(pipe);

// 2. Solve and size the vessel and compressor. Keep the installed pipe geometry:
// velocity-only auto-sizing does not enforce the hydraulic pressure budget of a long line.
process.run();
sep.autoSize(1.2);
comp.autoSize(1.2);
pipe.setMaxDesignVelocity(15.0);
pipe.initMechanicalDesign();
pipe.getMechanicalDesign().setMaxDesignPressureDrop(10.0); // bar, illustrative installed limit
sep.enableConstraints("gasLoadFactor");
pipe.enableAllConstraints();
process.applyMechanicalDesignCapacityConstraints();
process.run();

// 3. Constraints are now active and can be queried
logger.info("Equipment constraints after auto-sizing:");
for (CapacityConstrainedEquipment equip : process.getConstrainedEquipment()) {
    logger.info(((ProcessEquipmentInterface) equip).getName() + ":");
    for (CapacityConstraint c : equip.getCapacityConstraints().values()) {
        logger.info(String.format("  %s: %.2f / %.2f %s%n",
            c.getName(), c.getCurrentValue(), c.getDesignValue(), c.getUnit()));
    }
}

// 4. Use in optimization - optimizer checks ALL constraints
ProductionOptimizer.OptimizationConfig config =
    new ProductionOptimizer.OptimizationConfig(1000.0, 50000.0);
ProductionOptimizer optimizer = new ProductionOptimizer();
ProductionOptimizer.OptimizationResult result =
    optimizer.optimize(process, feed, config, null, null);

// 5. The bottleneck could be separator, compressor, or pipeline
if (result.getBottleneck() != null) {
    logger.info("Bottleneck: {}", result.getBottleneck().getName());
}

Equipment Currently Supporting CapacityConstrainedEquipment

Equipment Constraints Set By
Separator gasLoadFactor, liquidResidenceTime autoSize(), setDesignGasLoadFactor()
Compressor speed, power, ratedPower, surgeMargin, stonewallMargin autoSize(), setMaximumSpeed(), getMechanicalDesign().setMaxDesignPower()
Pump npshMargin, power, flowRate getMechanicalDesign().setMaxDesignPower(), mechanical design
ThrottlingValve valveOpening, cvUtilization, AIV autoSize(), setCv(), setMaxDesignAIV()
Pipeline velocity, pressureDrop, volumeFlow, FIV_LOF, FIV_FRMS autoSize(), getMechanicalDesign().setMaxDesignVelocity()
PipeBeggsAndBrills velocity, LOF, FRMS, AIV autoSize(), setMaxDesignVelocity(), setMaxDesignLOF(), setMaxDesignAIV()
AdiabaticPipe velocity, LOF, FRMS, AIV, pressureDrop autoSize(), setMaxDesignVelocity(), setMaxDesignLOF(), setMaxDesignAIV()
Manifold headerVelocity, branchVelocity, headerLOF, headerFRMS, branchLOF, branchFRMS autoSize(), setMaxDesignVelocity()
Heater/Cooler duty, outletTemperature autoSize(), setMaxDesignDuty()

How to Override autoSize Constraints

After autoSize() creates constraints, you can override them:

// 1. Override BEFORE autoSize (parameter will be used in sizing)
separator.setDesignGasLoadFactor(0.15);  // Your K-factor
separator.autoSize(1.2);                  // Uses your K-factor

// 2. Override AFTER autoSize (keeps sizing, changes constraint limit)
compressor.autoSize(1.2);
compressor.getMechanicalDesign().setMaxDesignPower(6000.0);  // Override constraint limit (kW)
compressor.setMaximumSpeed(12000.0);      // Override speed limit (RPM)

// 3. Manually set constraint on existing equipment
CapacityConstraint customPower = new CapacityConstraint("powerLimit", "kW", ConstraintType.HARD)
    .setDesignValue(5000.0)
    .setValueSupplier(() -> compressor.getPower("kW"));
compressor.addCapacityConstraint(customPower);

// 4. Remove auto-generated constraint and add custom one
compressor.removeCapacityConstraint("power");  // Remove default
compressor.addCapacityConstraint(customPower); // Add custom

Constraint Priority After Override

When you override a constraint parameter, the priority is:

  1. User-specified value (highest) - via setter methods
  2. autoSize calculated value - based on flow conditions
  3. Mechanical design default - from design standards
  4. Hard-coded default (lowest) - in equipment class

Usage Examples

Basic Usage: Process-Wide Bottleneck Detection

// Use an existing configured process containing rated equipment.
process.run();

// Find the process bottleneck
BottleneckResult bottleneck = process.findBottleneck();
logger.info("Process bottleneck: " + bottleneck.getEquipmentName());
logger.info("Limiting constraint: {}", bottleneck.getConstraintName());
logger.info("Utilization: " + bottleneck.getUtilizationPercent() + "%");

// Check if any equipment is overloaded
if (process.isAnyEquipmentOverloaded()) {
    logger.info("WARNING: Equipment operating above design capacity!");
}

// Check if any hard limits are exceeded (critical)
if (process.isAnyHardLimitExceeded()) {
    logger.info("CRITICAL: Hard equipment limits exceeded!");
}

// Get utilization summary for all equipment
Map<String, Double> utilization = process.getCapacityUtilizationSummary();
for (Map.Entry<String, Double> entry : utilization.entrySet()) {
    logger.info(String.format("%s: %.1f%%\n", entry.getKey(), entry.getValue()));
}

// Get equipment near capacity limit (early warning)
List<String> nearLimit = process.getEquipmentNearCapacityLimit();
if (!nearLimit.isEmpty()) {
    logger.info("Equipment near capacity: " + nearLimit);
}

ProcessModule Support

The capacity constraint framework also works with ProcessModule, which can contain multiple ProcessSystem instances and nested modules. All constraint methods work recursively across the entire module hierarchy.

import neqsim.process.processmodel.ProcessModule;

// Create a complex module with multiple systems
ProcessModule productionModule = new ProcessModule("Production Platform");

// Add process systems
ProcessSystem separationSystem = new ProcessSystem();
separationSystem.add(inletManifold);
separationSystem.add(hpSeparator);
separationSystem.add(lpSeparator);

ProcessSystem compressionSystem = new ProcessSystem();
compressionSystem.add(lpCompressor);
compressionSystem.add(hpCompressor);
compressionSystem.add(exportPipeline);

productionModule.add(separationSystem);
productionModule.add(compressionSystem);
productionModule.run();

// Find bottleneck across ALL systems in the module
BottleneckResult bottleneck = productionModule.findBottleneck();
if (bottleneck.hasBottleneck()) {
    logger.info("Module bottleneck: " + bottleneck.getEquipmentName());
    logger.info("Constraint: " + bottleneck.getConstraint().getName());
    logger.info("Utilization: " + bottleneck.getUtilizationPercent() + "%");
}

// Check for overloaded equipment across all systems
if (productionModule.isAnyEquipmentOverloaded()) {
    logger.info("WARNING: Equipment overloaded in module!");
}

// Get all constrained equipment from the module
List<CapacityConstrainedEquipment> allConstrained =
    productionModule.getConstrainedEquipment();
logger.info("Found " + allConstrained.size() + " constrained equipment items");

// Get utilization summary across entire module
Map<String, Double> utilization = productionModule.getCapacityUtilizationSummary();
for (Map.Entry<String, Double> entry : utilization.entrySet()) {
    logger.info(String.format("%s: %.1f%%\n", entry.getKey(), entry.getValue()));
}

Nested Module Support

ProcessModule supports nesting, and constraint methods work recursively:

// Create nested modules
ProcessModule topside = new ProcessModule("Topside");
ProcessModule subsea = new ProcessModule("Subsea");

// Each child must be a ProcessSystem or ProcessModule.
ProcessSystem subseaSystem = new ProcessSystem();
subseaSystem.add(subseaManifold);
subseaSystem.add(flowline);
subseaSystem.add(riser);
subsea.add(subseaSystem);

topside.add(separationSystem);
topside.add(compressionSystem);

// Create master module containing both
ProcessModule field = new ProcessModule("Field Development");
field.add(subsea);
field.add(topside);
field.run();

// findBottleneck() searches recursively through ALL nested modules
BottleneckResult fieldBottleneck = field.findBottleneck();

// All constraint methods work recursively
List<CapacityConstrainedEquipment> allEquipment = field.getConstrainedEquipment();
Map<String, Double> fieldUtilization = field.getCapacityUtilizationSummary();
boolean anyOverloaded = field.isAnyEquipmentOverloaded();
boolean hardLimitExceeded = field.isAnyHardLimitExceeded();

ProcessModule Constraint Methods

Method Description
getConstrainedEquipment() Returns all equipment implementing CapacityConstrainedEquipment from all systems and nested modules
findBottleneck() Finds the equipment with highest utilization across entire module hierarchy
isAnyEquipmentOverloaded() Checks if any equipment exceeds design capacity (utilization > 100%)
isAnyHardLimitExceeded() Checks if any HARD constraint limits are exceeded
getCapacityUtilizationSummary() Returns Map<String, Double> of equipment name to utilization percentage
getEquipmentNearCapacityLimit() Returns list of equipment names near warning threshold

Individual Equipment Inspection

// Get a specific compressor
Compressor compressor = (Compressor) process.getUnit("27-KA-01");

// Check overall capacity status
logger.info("Max utilization: " + compressor.getMaxUtilizationPercent() + "%");
logger.info("Available margin: " + compressor.getAvailableMarginPercent() + "%");

// Inspect individual constraints
Map<String, CapacityConstraint> constraints = compressor.getCapacityConstraints();
for (CapacityConstraint c : constraints.values()) {
    logger.info(String.format("  %s: %.1f / %.1f %s (%.1f%% utilized)\n",
        c.getName(), c.getCurrentValue(), c.getDesignValue(),
        c.getUnit(), c.getUtilizationPercent()));
}

// Get the bottleneck constraint for this equipment
CapacityConstraint limiting = compressor.getBottleneckConstraint();
if (limiting != null) {
    logger.info("Limiting factor: {}", limiting.getName());
}

Adding Custom Constraints at Runtime

// Use a solved separator that actually contains oil, with configured vessel geometry.
CapacityConstraint residenceTime = StandardConstraintType.SEPARATOR_OIL_RETENTION_TIME
    .createConstraint()
    .setMinValue(3.0)  // minutes; leave designValue unset for a minimum constraint
    .setValueSupplier(() -> separator.calcOilRetentionTime());
separator.addCapacityConstraint(residenceTime);
logger.info("Oil retention utilization: {}%", residenceTime.getUtilizationPercent());

// Remove a specific optional constraint when the study scope calls for it.
separator.removeCapacityConstraint("gasLoadFactor");

Activating and Deactivating Constraints

Adding Constraints to Equipment WITH Existing Constraints

Equipment that already implements CapacityConstrainedEquipment (Separator, Compressor, Pipeline, Manifold, etc.) can have additional constraints added:

// Equipment already has default constraints from autoSize() or initialization
Compressor compressor = new Compressor("Export Compressor", feed);
compressor.setOutletPressure(150.0);
compressor.autoSize(1.2);  // Creates speed, power, surgeMargin constraints
compressor.run();

// View existing constraints
logger.info("Current constraints:");
for (CapacityConstraint c : compressor.getCapacityConstraints().values()) {
    logger.info("  " + c.getName() + ": " + c.getDesignValue() + " " + c.getUnit());
}

// ADD a new custom constraint (discharge temperature)
CapacityConstraint tempLimit = new CapacityConstraint("dischargeTemp", "°C", ConstraintType.SOFT)
    .setDesignValue(150.0)  // °C design limit
    .setMaxValue(180.0)     // °C absolute max
    .setUnit("°C")
    .setWarningThreshold(0.9)
    .setValueSupplier(() -> compressor.getOutletStream().getTemperature("C"));

compressor.addCapacityConstraint(tempLimit);

// MODIFY an existing constraint's design value
CapacityConstraint speedConstraint = compressor.getCapacityConstraints().get("speed");
if (speedConstraint != null) {
    speedConstraint.setDesignValue(9500.0);  // Lower speed limit
    speedConstraint.setMaxValue(10000.0);
}

Adding Constraints to Equipment WITHOUT Existing Constraints

All ProcessEquipmentBaseClass descendants already expose constraint methods. Start with a direct constraint; no duplicate map or interface implementation is needed:

Heater heater = new Heater("Process Heater", feed);
heater.setOutTemperature(350.0); // K
heater.run();
heater.addCapacityConstraint(new CapacityConstraint("installedDuty", "kW", ConstraintType.HARD)
    .setDesignValue(5000.0)
    .setValueSupplier(() -> Math.abs(heater.getDuty()) / 1000.0));

For a reusable subclass, retain the inherited constraint storage and simulation:

public class ConstrainedHeater extends Heater {
  private static final long serialVersionUID = 1L;

  public ConstrainedHeater(String name, StreamInterface inletStream) {
    super(name, inletStream);
    addCapacityConstraint(new CapacityConstraint("installedDuty", "kW", ConstraintType.HARD)
        .setDesignValue(5000.0)
        .setValueSupplier(() -> Math.abs(getDuty()) / 1000.0));
  }
}

Deactivating (Removing) Constraints

// Remove a specific constraint by name
compressor.removeCapacityConstraint("surgeMargin");

// Remove multiple constraints
compressor.removeCapacityConstraint("stonewallMargin");
compressor.removeCapacityConstraint("dischargeTemp");

// Clear the current definitions; equipment may rebuild defaults on later access.
compressor.clearCapacityConstraints();

// Re-initialize default constraints after clearing
compressor.reinitializeCapacityConstraints();  // Public API

Temporarily Disabling Constraints

For scenarios where you want to keep constraints defined but temporarily ignore them:

CapacityConstraint speedConstraint = compressor.getCapacityConstraints().get("speed");
boolean wasEnabled = speedConstraint.isEnabled();
try {
    speedConstraint.setEnabled(false);
    // Run the explicitly scoped what-if calculation here.
    process.run();
} finally {
    speedConstraint.setEnabled(wasEnabled);
}

Constraints in Eclipse VFP Table Generation

Capacity curves and VFPPROD tables are different data products. A capacity curve reports maximum feasible flow for pressure boundaries. A VFPPROD table reports bottom-hole pressure on flow, THP, water-fraction, gas-ratio, and artificial-lift axes. Do not put maximum rates into BHP cells or interpret unavailable pressure cells as zero pressure.

How Constraints Affect VFP Tables

Solve and qualify each hydraulic operating point first. Record constraints alongside the calculated pressure table; the exporter itself neither solves the process nor enforces constraints. LiftCurveTable.toDiagnosticTable() is a pressure matrix, not a VFPPROD keyword; the process capacity/lift tables reject toEclipseFormat(). Use the supplied-BHP export contract for deck output.

VFP Generation with Constraint Checking

This minimal serialization example uses explicitly supplied illustrative BHP data; it does not claim these numbers were calculated from the feed above. Replace the data with a validated hydraulic study. This example uses singleton zero composition/lift axes; the writer also preserves complete multidimensional grids and rejects infeasible cells.

EclipseVFPExporter exporter = new EclipseVFPExporter(1);
exporter.setDatumDepth(1500.0); // m
exporter.setFlowRateType("GAS");
exporter.setWaterCutType("WGR");
exporter.setGORType("OGR");
exporter.setUnitSystem("METRIC");
exporter.setFlowRates(new double[] {10000.0, 20000.0}); // standard m3/day
exporter.setTHPs(new double[] {30.0, 40.0}); // bara
exporter.setWaterCuts(new double[] {0.0});
exporter.setGORs(new double[] {0.0});
exporter.setALQs(new double[] {0.0});
// Index order: flow, THP, water fraction, gas ratio, lift quantity.
double[][][][][] bhp = new double[2][2][1][1][1];
bhp[0][0][0][0][0] = 35.0;
bhp[1][0][0][0][0] = 42.0;
bhp[0][1][0][0][0] = 45.0;
bhp[1][1][0][0][0] = 52.0;
exporter.setBHPTable(bhp);
String vfpTable = exporter.getVFPPRODString();

Validate exported deck syntax and units in the target simulator before using a table in reservoir calculations; this Java test verifies the exporter API and data serialization.

Understanding Constraint Impact on VFP

For a solved process with a configured compressor, compare bounded throughput searches and restore the exact original constraint enablement. These are capacity results, not BHP:

ProductionOptimizer optimizer = new ProductionOptimizer();
ProductionOptimizer.OptimizationConfig config =
    new ProductionOptimizer.OptimizationConfig(1000.0, 20000.0).rateUnit("kg/hr");
ProductionOptimizer.OptimizationResult baseline =
    optimizer.optimize(process, feed, config, null, null);
CapacityConstraint speedLimit = compressor.getCapacityConstraints().get("speed");
boolean enabled = speedLimit.isEnabled();
try {
    speedLimit.setEnabled(false);
    ProductionOptimizer.OptimizationResult relaxed =
        optimizer.optimize(process, feed, config, null, null);
    if (baseline.isFeasible() && relaxed.isFeasible()) {
        logger.info("Capacity change: {} kg/hr", relaxed.getOptimalRate() - baseline.getOptimalRate());
    }
} finally {
    speedLimit.setEnabled(enabled);
}

Modifying Constraints for What-If VFP Studies

Changing a gas-load-factor limit changes allowable loading; it does not enlarge vessel geometry. A vessel upgrade requires new diameter/length, a new solve, and new rating constraints. Archive validated BHP tables with Java 8 APIs:

// In a method declaring throws java.io.IOException, after populating exporter:
java.nio.file.Files.write(java.nio.file.Paths.get("VFP_BASELINE.INC"),
    exporter.getVFPPRODString().getBytes(java.nio.charset.StandardCharsets.UTF_8));

Constraint-Aware Lift Curve Generation

Use PressureBoundaryOptimizer for a pressure-boundary capacity matrix. This example requires outlet from a process whose outlet pressure is solved or controlled at 30 bara:

PressureBoundaryOptimizer boundary = new PressureBoundaryOptimizer(process, feed, outlet);
boundary.setMinFlowRate(1000.0);
boundary.setMaxFlowRate(20000.0);
boundary.setAutoConfigureCompressors(false); // preserve the model's configured maps
LiftCurveTable table = boundary.generateLiftCurveTable(
    new double[] {40.0, 50.0}, new double[] {30.0}, "bara");
for (int i = 0; i < 2; i++) {
    logger.info("Inlet row {}: max flow={} kg/hr, power={} kW", i,
        table.getFlowRate(i, 0), table.getPower(i, 0));
}

The wrapper checks the requested outlet pressure; it does not retarget valve or compressor setpoints. See Pressure Boundary Optimization.

Summary: Constraint Management for VFP Tables

Action API Interpretation
Add or tighten a maximum addCapacityConstraint, setDesignValue May reduce feasible capacity
Tighten a minimum setMinValue with design unset May reduce feasible capacity
Disable one restriction setEnabled(false) Other equipment limits and fallback rules still apply
Exclude equipment analysis setCapacityAnalysisEnabled(false) Explicitly changes the study scope
Upgrade installed equipment Change geometry/rating, solve, regenerate evidence New physical candidate, then a new table

Integration with Optimization

/** Finds a bounded feasible throughput; rates and tolerance are in kmol/hr. */
public double findMaxThroughput(ProcessSystem process, double minimumRate, double maximumRate) {
    StreamInterface feed = (StreamInterface) process.getUnit("well stream");
    ProductionOptimizer.OptimizationConfig config =
        new ProductionOptimizer.OptimizationConfig(minimumRate, maximumRate)
            .rateUnit("kmol/hr").tolerance(0.01).maxIterations(50);
    ProductionOptimizer.OptimizationResult result =
        new ProductionOptimizer().optimize(process, feed, config, null, null);
    if (!result.isFeasible()) {
        throw new IllegalStateException("No feasible throughput inside the configured bounds");
    }
    feed.setFlowRate(result.getOptimalRate(), "kmol/hr");
    process.run();
    return result.getOptimalRate();
}

Extending to Other Equipment

Step-by-Step Guide

Reuse inherited constraint storage and public equipment APIs. This avoids duplicate maps, missing simulation implementations, and accidental loss of disabled-constraint handling.

Step 1: Implement the Interface

A ProcessEquipmentBaseClass subclass already provides capacity methods. Extend an appropriate working equipment class; explicit CapacityConstrainedEquipment implementation is only needed when a consumer requires that marker interface.

Step 2: Initialize Default Constraints in Constructor

public class MyEquipment extends Stream implements CapacityConstrainedEquipment {
  private static final long serialVersionUID = 1L;

  public MyEquipment(String name, StreamInterface inlet) {
    super(name, inlet);
    addCapacityConstraint(new CapacityConstraint("flowRate", "m3/hr", ConstraintType.HARD)
        .setDesignValue(100.0)
        .setValueSupplier(() -> getFlowRate("m3/hr")));
  }

  public void setDesignFlowRate(double flowRate) {
    getCapacityConstraints().get("flowRate").setDesignValue(flowRate);
  }
}

Step 3: Implement Required Interface Methods

The example inherits the implementations, including enablement, bottleneck selection, utilization, and mutation methods. Do not reimplement them with loops that ignore isEnabled() or unavailable values.

Step 4: Update Constraints When Design Values Change

MyEquipment equipment = new MyEquipment("Rated line", feed);
equipment.setDesignFlowRate(150.0); // actual m3/hr
equipment.run();
double utilization = equipment.getMaxUtilization();

Example: Implementing for Pump

Use a solved liquid pump with an installed motor rating and vendor NPSH requirement:

CapacityConstraint power = StandardConstraintType.PUMP_POWER.createConstraint()
    .setDesignValue(500.0) // illustrative motor shaft rating, kW
    .setValueSupplier(() -> pump.getPower("kW"));
pump.addCapacityConstraint(power);
CapacityConstraint npsh = StandardConstraintType.PUMP_NPSH_MARGIN.createConstraint()
    .setMinValue(1.0) // illustrative required NPSHa - NPSHr headroom, m
    .setValueSupplier(() -> pump.getNPSHAvailable() - pump.getNPSHRequired());
pump.addCapacityConstraint(npsh);

Example: Implementing for Heat Exchanger

Use a solved two-stream HeatExchanger exchanger:

CapacityConstraint duty = StandardConstraintType.HEAT_EXCHANGER_DUTY.createConstraint()
    .setDesignValue(1000.0) // kW
    .setValueSupplier(() -> Math.abs(exchanger.getDuty()) / 1000.0);
exchanger.addCapacityConstraint(duty);
CapacityConstraint approach = StandardConstraintType.HEAT_EXCHANGER_APPROACH_TEMP.createConstraint()
    .setMinValue(5.0) // temperature difference: K and degrees C have the same increment
    .setValueSupplier(() -> exchanger.getApproachTemperature());
exchanger.addCapacityConstraint(approach);

Example: Implementing for Pipe/Pipeline

Use a solved PipeBeggsAndBrills pipe. The standard erosional constraint uses percent, whereas PIPE_PRESSURE_DROP uses a gradient in bar/km, not total drop:

CapacityConstraint velocity = StandardConstraintType.PIPE_VELOCITY.createConstraint()
    .setDesignValue(15.0)
    .setValueSupplier(() -> pipe.getMixtureVelocity());
pipe.addCapacityConstraint(velocity);
CapacityConstraint erosional = StandardConstraintType.PIPE_EROSIONAL_VELOCITY.createConstraint()
    .setDesignValue(100.0)
    .setValueSupplier(() -> 100.0 * pipe.getMixtureVelocity() / pipe.getErosionalVelocity());
pipe.addCapacityConstraint(erosional);
CapacityConstraint gradient = StandardConstraintType.PIPE_PRESSURE_DROP.createConstraint()
    .setDesignValue(2.0)
    .setValueSupplier(() -> pipe.getPressureDrop() / (pipe.getLength() / 1000.0));
pipe.addCapacityConstraint(gradient);

StandardConstraintType Reference

Category Type Name Unit Description
Separator SEPARATOR_GAS_LOAD_FACTOR gasLoadFactor m/s Souders-Brown K-factor
  SEPARATOR_RESIDENCE_TIME residenceTime min Liquid hold-up time
  (custom) liquidLevel % Level as % of capacity
Compressor COMPRESSOR_SPEED speed RPM Maximum rotational speed
  COMPRESSOR_MIN_SPEED minSpeed RPM Minimum stable speed (from curve)
  COMPRESSOR_POWER power kW Standard shaft-power constraint; native compressor power may use %
  (custom) ratedPower % Power utilization vs driver rated power
  COMPRESSOR_SURGE_MARGIN surgeMargin % Distance to surge
  COMPRESSOR_STONEWALL_MARGIN stonewallMargin % Distance to stonewall
  COMPRESSOR_DISCHARGE_TEMP dischargeTemp °C Discharge temperature
  (custom) pressureRatio - Compression ratio
Pump PUMP_FLOW_RATE flowRate m³/hr Volumetric flow
  (custom) head m Developed head
  PUMP_POWER power kW Shaft power
  PUMP_NPSH_MARGIN npshMargin m NPSH available margin
Heat Exchanger HEAT_EXCHANGER_DUTY duty kW Heat transfer rate
  HEAT_EXCHANGER_APPROACH_TEMP approachTemp °C Minimum ΔT
  HEAT_EXCHANGER_PRESSURE_DROP pressureDrop bar Pressure loss
Valve VALVE_CV_UTILIZATION cvUtilization % Cv used / Cv available
  VALVE_PRESSURE_DROP pressureDrop bar Pressure loss
  (custom) AIV kW Acoustic-induced vibration power
Pipe PIPE_VELOCITY velocity m/s Fluid velocity
  PIPE_EROSIONAL_VELOCITY erosionalVelocityRatio % 100 × v/v_erosional
  PIPE_PRESSURE_DROP pressureDropPerLength bar/km Pressure gradient
  (custom) AIV kW Acoustic-induced vibration power

Notes:

Flow-Induced Vibration (FIV) Analysis

Pipeline equipment (Pipeline, PipeBeggsAndBrills, AdiabaticPipe, Manifold) includes built-in FIV analysis capabilities with constraints based on industry standards.

FIV Metrics

Metric Description Risk Threshold
LOF (Likelihood of Failure) Dimensionless indicator based on density, velocity, GVF, and support stiffness > 0.6 = High risk
FRMS RMS force per meter (N/m) - dynamic loading indicator > 500 N/m = High risk
Erosional Velocity Maximum velocity per API RP 14E: Ve = C/√ρ > 100% = Erosion risk

Support Arrangement Coefficients

The LOF calculation uses support arrangement coefficients per industry practice:

Support Type Coefficient Description
Stiff 1.0 Rigid supports, short spans
Medium stiff 1.5 Standard pipe racks
Medium 2.0 Longer spans, typical offshore
Flexible 3.0 Flexible supports, risers

Using FIV Analysis

// Pipeline with FIV constraints
PipeBeggsAndBrills pipe = new PipeBeggsAndBrills("Export Line", feed);
pipe.setLength(5000.0);
pipe.setDiameter(0.2032);  // 8 inch
pipe.setThickness(0.008);   // 8mm wall
pipe.setSupportArrangement("Medium stiff");
pipe.run();

// Get FIV metrics
double lof = pipe.calculateLOF();
double frms = pipe.calculateFRMS();
double erosionalVel = pipe.getErosionalVelocity();
double actualVel = pipe.getMixtureVelocity();

logger.info(String.format("LOF: %.3f (Risk: %s)%n", lof, lof > 0.6 ? "HIGH" : "Low"));
logger.info(String.format("FRMS: %.1f N/m%n", frms));
logger.info(String.format("Velocity: %.2f / %.2f m/s (%.1f%% of erosional)%n",
    actualVel, erosionalVel, 100 * actualVel / erosionalVel));

// Get full FIV analysis as Map
Map<String, Object> fivAnalysis = pipe.getFIVAnalysis();

// Get FIV analysis as JSON
String fivJson = pipe.getFIVAnalysisJson();

FIV Analysis Output (JSON)

{
  "LOF": 0.234,
  "LOF_risk": "Low",
  "FRMS_N_per_m": 125.6,
  "FRMS_risk": "Low",
  "mixtureDensity_kg_m3": 85.2,
  "mixtureVelocity_m_s": 12.4,
  "erosionalVelocity_m_s": 18.5,
  "velocityRatio": 0.67,
  "gasVolumeFraction": 0.92,
  "supportArrangement": "Medium stiff",
  "supportCoefficient": 1.5,
  "innerDiameter_m": 0.1872
}

Manifold FIV Analysis

Manifolds provide separate FIV analysis for header and branch lines:

Manifold manifold = new Manifold("Production Manifold");
manifold.addStream(inlet1);
manifold.addStream(inlet2);
manifold.setSplitFactors(new double[] {0.4, 0.3, 0.3});
manifold.setMaxHeaderVelocityDesign(15.0);
manifold.setMaxBranchVelocityDesign(15.0);
manifold.setHeaderInnerDiameter(0.3);
manifold.setBranchInnerDiameter(0.15);
manifold.run();

// Header FIV
double headerLOF = manifold.calculateHeaderLOF();
double headerFRMS = manifold.calculateHeaderFRMS();

// Branch FIV (uses average branch flow)
double branchLOF = manifold.calculateBranchLOF();

// All constraints
Map<String, CapacityConstraint> constraints = manifold.getCapacityConstraints();
// Contains: headerVelocity, branchVelocity, headerLOF, headerFRMS, branchLOF

FIV Design Limits

Set design limits for FIV constraints:

// Set maximum allowable values
pipe.setMaxDesignVelocity(15.0);  // m/s
pipe.setMaxDesignLOF(0.5);        // dimensionless
pipe.setMaxDesignFRMS(400.0);     // N/m

// These become constraint design values
CapacityConstraint lofConstraint = pipe.getCapacityConstraints().get("LOF");
// lofConstraint.getDesignValue() returns 0.5

Note: The setter methods (setMaxDesignVelocity, setMaxDesignLOF, setMaxDesignFRMS, setMaxDesignAIV) clear the constraint map, so new values take effect when getCapacityConstraints() is called. Configure these limits before adding custom constraints, or reapply the custom constraints afterward. If you need to explicitly reinitialize constraints after other changes, call pipe.reinitializeCapacityConstraints().

Acoustic-Induced Vibration (AIV) Analysis

AIV is caused by high acoustic energy generated by pressure-reducing devices (valves, orifices) and is particularly relevant for high-pressure gas systems. Unlike FIV (which relates to liquid slugging), AIV is critical for dry gas systems.

AIV Formula (Energy Institute Guidelines)

The acoustic power is calculated using the Energy Institute Guidelines formula:

\[W_{acoustic} = 3.2 \times 10^{-9} \cdot \dot{m} \cdot P_1 \cdot \left(\frac{\Delta P}{P_1}\right)^{3.6} \cdot \left(\frac{T}{273.15}\right)^{0.8}\]

Where:

AIV Risk Levels

Acoustic Power (kW) Risk Level Action Required
< 1 LOW No action required
1 - 10 MEDIUM Review piping layout
10 - 25 HIGH Detailed analysis required
> 25 VERY HIGH Mitigation required

Using AIV Analysis in Pipes

// Pipeline with AIV constraint
PipeBeggsAndBrills pipe = new PipeBeggsAndBrills("HP Gas Line", feed);
pipe.setLength(100.0);
pipe.setDiameter(0.2032);  // 8 inch
pipe.setThickness(0.008);   // 8mm wall
pipe.run();

// Get AIV metrics
double aivPower = pipe.calculateAIV();  // kW
double aivLOF = pipe.calculateAIVLikelihoodOfFailure();

logger.info(String.format("AIV Power: %.2f kW%n", aivPower));
logger.info(String.format("AIV LOF: %.2f%n", aivLOF));

// Set AIV design limit (default is 25 kW)
pipe.setMaxDesignAIV(10.0);  // kW

// Get FIV analysis (now includes AIV)
Map<String, Object> analysis = pipe.getFIVAnalysis();
// Contains: AIV_power_kW, AIV_risk, AIV_LOF

Using AIV Analysis in Valves

Throttling valves are primary sources of AIV due to large pressure drops:

// Control valve with significant pressure drop
ThrottlingValve valve = new ThrottlingValve("PCV-100", feed);
valve.setOutletPressure(30.0, "bara");  // Large ΔP
valve.run();

// Get AIV metrics
double aivPower = valve.calculateAIV();  // kW

// Calculate AIV LOF (requires downstream pipe geometry)
double downstreamDiameter = 0.2032;  // 8 inch
double downstreamThickness = 0.008;  // 8mm
double aivLOF = valve.calculateAIVLikelihoodOfFailure(
    downstreamDiameter, downstreamThickness);

logger.info(String.format("Valve AIV Power: %.2f kW%n", aivPower));
logger.info(String.format("Valve AIV LOF: %.3f%n", aivLOF));

// Set AIV design limit (default is 10 kW for valves)
valve.setMaxDesignAIV(5.0);  // kW - stricter limit

// Access AIV constraint
CapacityConstraint aivConstraint = valve.getCapacityConstraints().get("AIV");
double utilization = aivConstraint.getUtilization();

AIV Analysis Output (JSON)

The getFIVAnalysis() method now includes AIV data:

{
  "LOF": 0.05,
  "LOF_risk": "Low",
  "FRMS_N_per_m": 12.3,
  "FRMS_risk": "Low",
  "AIV_power_kW": 8.45,
  "AIV_risk": "MEDIUM",
  "AIV_LOF": 0.35,
  "mixtureDensity_kg_m3": 45.2,
  "mixtureVelocity_m_s": 18.4,
  "erosionalVelocity_m_s": 25.5,
  "velocityRatio": 0.72,
  "gasVolumeFraction": 0.98,
  "supportArrangement": "Medium stiff",
  "supportCoefficient": 1.5,
  "innerDiameter_m": 0.1872
}

FIV vs AIV: When to Use Each

Metric Applicable Systems Primary Concern
LOF/FRMS (FIV) Two-phase flow with liquid slugging Liquid impacts causing pipe vibration
AIV High-pressure gas with pressure drops Acoustic energy from turbulent flow

For dry gas systems, AIV is typically more relevant than FIV (LOF/FRMS will be near zero)


Best Practices

1. Choose Appropriate Constraint Types

2. Set Meaningful Design Values

Design values should represent the intended operating point, not the maximum:

// Good: Design at normal operation, max at limit
constraint.setDesignValue(10000.0);  // Normal speed
constraint.setMaxValue(11000.0);     // Trip speed

// Bad: Design equals maximum
constraint.setDesignValue(11000.0);  // No warning margin

3. Use Warning Thresholds

The default warning threshold is 90%. Adjust if needed:

constraint.setWarningThreshold(0.85);  // Warn at 85% utilization

4. Handle Missing Data Gracefully

The valueSupplier should return Double.NaN for unavailable data:

CapacityConstraint speed = new CapacityConstraint("speed", "rpm", ConstraintType.HARD)
    .setDesignValue(10000.0)
    .setValueSupplier(() -> compressor.getCompressorChart().isUseCompressorChart()
        ? compressor.getSpeed() : Double.NaN);

5. Update Constraints When Design Changes

Ensure constraints stay synchronized with design parameters:

CapacityConstraint speed = compressor.getCapacityConstraints().get("speed");
if (speed != null) {
    speed.setDesignValue(10000.0);
}

Equipment Capacity Strategy Registry

The Strategy Registry provides a plugin-based architecture for evaluating equipment capacity constraints without modifying equipment classes. The registry ships with 18 built-in strategies covering all major equipment categories:

Built-in Strategies (18 total)

Strategy Equipment Types Typical Constraints
CompressorCapacityStrategy Compressor speed, power, surgeMargin, stonewallMargin
SeparatorCapacityStrategy Separator, ThreePhaseSeparator gasLoadFactor, liquidResidenceTime, dropletCutSize
PipeCapacityStrategy Pipeline, AdiabaticPipe velocity, pressureDrop, FIV_LOF, FIV_FRMS
ValveCapacityStrategy ThrottlingValve valveOpening, cvUtilization
HeatExchangerCapacityStrategy Heater, Cooler duty, outletTemperature
PumpCapacityStrategy Pump npshMargin, power, flowRate
ExpanderCapacityStrategy Expander speed, power
EjectorCapacityStrategy Ejector compressionRatio, motiveFlow
MixerCapacityStrategy Mixer flowRate, pressureDiff
SplitterCapacityStrategy Splitter flowRate
TankCapacityStrategy Tank fillLevel, fillRate
DistillationColumnCapacityStrategy DistillationColumn floodingFactor, reboilerDuty
ReactorCapacityStrategy GibbsReactor, PlugFlowReactor, StirredTankReactor throughput, residenceTime, conversionRate
PowerGenerationCapacityStrategy GasTurbine, SteamTurbine, HRSG, CombinedCycleSystem power, fuelFlow, exhaustTemp
SubseaEquipmentCapacityStrategy SubseaWell, SubseaTree flowRate, wellheadPressure, chokeOpening
FilterAdsorberCapacityStrategy Filter, SulfurFilter, CharCoalFilter, SimpleAdsorber pressureDrop, throughput
ElectrolyzerCapacityStrategy Electrolyzer, CO2Electrolyzer power, currentDensity, efficiency
WellFlowCapacityStrategy WellFlow flowRate, wellheadPressure, drawdown

Expander note (equipment-level override). The ExpanderCapacityStrategy above belongs to the older CapacityAnalysisEngine path. On the getMaxUtilization() / getUtilizationSnapshotJson() path, Expander overrides the inherited Compressor logic: it removes the inherited consumed-power constraints (power, ratedPower) — which are meaningless for a machine that produces shaft power — and, when a rating is set via expander.setRatedRecoveredPower(kW), adds a recoveredPower HARD constraint sourced from |getPower|. It also overrides isSimulationValid() so an expander’s normal state (negative shaft power, outlet colder than inlet, pressure ratio < 1) is treated as valid. This removes the previously spurious ~150 % expander utilization. See Expanders (Turbo-Expanders) below.

Strategy Architecture

┌─────────────────────────────────────────────────────────────────────┐
│            EquipmentCapacityStrategyRegistry (Singleton)            │
│  ┌─────────────────────────────────────────────────────────────────┐│
│  │  findStrategy(equipment)  │  getAllStrategies()                 ││
│  │  register(strategy)       │  getConstraints(equipment)         ││
│  └─────────────────────────────────────────────────────────────────┘│
│                              │                                       │
│         ┌────────────────────┴────────────────────┐                  │
│         ▼                                         ▼                  │
│  ┌──────────────────────┐             ┌─────────────────────────────┐│
│  │ Built-in (18)        │             │  Custom Strategies          ││
│  │ Compressor, Separator│             │  MyEquipmentStrategy        ││
│  │ Pump, Valve, Pipe    │             │  VendorSpecificStrategy     ││
│  │ Reactor, PowerGen    │             │  ...                        ││
│  │ Subsea, Filter       │             │                             ││
│  │ Electrolyzer, Well   │             │                             ││
│  └──────────────────────┘             └─────────────────────────────┘│
└─────────────────────────────────────────────────────────────────────┘

Universal Constraint Support: Since all equipment inherits constraint methods from ProcessEquipmentBaseClass, you can add constraints to ANY equipment — even types without a dedicated strategy. The strategy registry provides pre-configured constraints; manual addCapacityConstraint() works on all equipment.

Using the Strategy Registry

import neqsim.process.equipment.capacity.EquipmentCapacityStrategyRegistry;
import neqsim.process.equipment.capacity.EquipmentCapacityStrategy;

// Get the singleton registry
EquipmentCapacityStrategyRegistry registry =
    EquipmentCapacityStrategyRegistry.getInstance();

// Find strategy for a specific equipment
Compressor compressor = (Compressor) process.getUnit("ExportCompressor");
EquipmentCapacityStrategy strategy = registry.findStrategy(compressor);

if (strategy != null) {
    // Evaluate capacity
    double utilization = strategy.evaluateCapacity(compressor);
    logger.info(String.format("Compressor utilization: %.1f%%\n", utilization * 100));

    // Get all constraints
    Map<String, CapacityConstraint> constraints = strategy.getConstraints(compressor);
    for (CapacityConstraint c : constraints.values()) {
        logger.info(String.format("  %s: %.2f %s (%.1f%% of design)\n",
            c.getName(), c.getCurrentValue(), c.getUnit(),
            c.getUtilizationPercent()));
    }

    // Check for violations
    List<CapacityConstraint> violations = strategy.getViolations(compressor);
    if (!violations.isEmpty()) {
        logger.info("Constraint violations:");
        for (CapacityConstraint v : violations) {
            logger.info(String.format("  - %s: %.2f exceeds %.2f\n",
                v.getName(), v.getCurrentValue(), v.getDesignValue()));
        }
    }

    // Get bottleneck constraint
    CapacityConstraint bottleneck = strategy.getBottleneckConstraint(compressor);
    if (bottleneck != null) {
        logger.info("Bottleneck: {}", bottleneck.getName());
    }
}

Creating Custom Strategies

Extend an existing strategy when its equipment support and evaluation methods are appropriate. This implementation adds a rated duty limit while retaining the complete strategy contract:

public class MyCustomStrategy extends HeatExchangerCapacityStrategy {
  @Override
  public boolean supports(ProcessEquipmentInterface equipment) {
    return equipment instanceof Heater && equipment.getName().equals("Process Heater");
  }

  @Override
  public int getPriority() {
    return 100;
  }

  @Override
  public String getName() {
    return "InstalledHeaterDutyStrategy";
  }

  @Override
  public double evaluateCapacity(ProcessEquipmentInterface equipment) {
    return getConstraints(equipment).get("installedDuty").getUtilization();
  }

  @Override
  public double evaluateMaxCapacity(ProcessEquipmentInterface equipment) {
    return 5000.0; // kW, matching installedDuty
  }

  @Override
  public Map<String, CapacityConstraint> getConstraints(ProcessEquipmentInterface equipment) {
    Heater heater = (Heater) equipment;
    Map<String, CapacityConstraint> constraints = new LinkedHashMap<>();
    constraints.put("installedDuty", new CapacityConstraint("installedDuty", "kW", ConstraintType.HARD)
        .setDesignValue(5000.0)
        .setValueSupplier(() -> Math.abs(heater.getDuty()) / 1000.0));
    return constraints;
  }
}

Register the class from a method after its definition:

EquipmentCapacityStrategyRegistry.getInstance().register(new MyCustomStrategy());

Built-in Strategies

Strategy Equipment Type Constraints Evaluated
CompressorCapacityStrategy Compressor speed, power, surgeMargin, stonewallMargin, dischargeTemperature
SeparatorCapacityStrategy Separator liquidLevel, gasLoadFactor
PumpCapacityStrategy Pump power, npshMargin, flowRate
ValveCapacityStrategy Valve valveOpening, pressureDropRatio
PipeCapacityStrategy Pipeline velocity, pressureDrop
HeatExchangerCapacityStrategy HeatExchanger duty, outletTemperature

For detailed usage and integration with the ProcessOptimizationEngine, see Optimizer Plugin Architecture.

Integration with OilGasProcessSimulationOptimization

The example simulation class demonstrates integration:

// After running the process
neqsim.process.examples.OilGasProcessSimulationOptimization.ProcessOutputResults results =
    simulation.getOutput();

// Check separator capacity
if (results.isAnySeparatorOverloaded()) {
    logger.info("Separator capacity exceeded!");
    for (Map.Entry<String, Double> e : results.getSeparatorCapacityUtilization().entrySet()) {
        if (e.getValue() > 100.0) {
            logger.info(String.format("  %s at %.1f%%\n", e.getKey(), e.getValue()));
        }
    }
}

// Check compressor speed limits
if (results.isAnyCompressorOverspeed()) {
    logger.info("Compressor speed limit exceeded!");
}

// Use ProcessSystem methods for deeper analysis
ProcessSystem process = simulation.getOilProcess();
BottleneckResult bottleneck = process.findBottleneck();

Capacity Utilization Snapshot (ML / RL Observation Vector)

Both ProcessSystem and ProcessModel expose getUtilizationSnapshotJson(), and the ProcessAutomation facade exposes getUtilizationSnapshot() which delegates to whichever it wraps. The snapshot is a side-effect-free JSON view of every unit’s capacity utilization — it never calls run(), it only reads the utilization already computed by each unit’s constraints. This makes it the canonical observation vector for closed-loop and reinforcement-learning optimization, paired with ProcessAutomation.evaluate(...) (the action + reward step).

ProcessAutomation auto = plant.getAutomation();
plant.run(); // or auto.evaluate(...) — the snapshot reflects the most recent solve
String json = auto.getUtilizationSnapshot();

The returned JSON (schema "1.0") has the shape:

{
  "schemaVersion": "1.0",
  "units": [
    {
      "area": "Export compression",
      "name": "30-KA-01",
      "type": "Compressor",
      "capacityAnalysisEnabled": true,
      "maxUtilization": 0.83,
      "maxUtilizationPercent": 83.0,
      "limitingConstraint": "power",
      "feasible": true,
      "hardLimitExceeded": false,
      "power_kW": 1240.5,
      "constraints": [
        {"name": "power", "utilization": 0.83, "utilizationPercent": 83.0,
         "current": 83.0, "design": 100.0, "unit": "%", "enabled": true, "violated": false,
         "dataSource": "design"}
      ]
    }
  ],
  "bottleneck": {"area": "Export compression", "name": "30-KA-01",
                 "qualifiedName": "Export compression::30-KA-01", "utilization": 0.83,
                 "utilizationPercent": 83.0, "limitingConstraint": "power"},
  "anyOverloaded": false,
  "anyHardLimitExceeded": false
}
Per-unit snapshot fields
FieldMeaning
areaProcess-area name (only present in a ProcessModel snapshot)
name / typeUnit name and simple class name
maxUtilizationHighest enabled-constraint utilization (0–1; NaN reported as 0)
limitingConstraintName of the constraint driving maxUtilization (or null)
feasibletrue when no enabled constraint is exceeded
power_kWShaft power, present for compressors and pumps only
constraints[]Per-constraint breakdown (utilization, current, design, unit, enabled, violated, and dataSource when set)
dataSourceProvenance tag on each constraint (e.g. "equipment", "design") — lets an agent distinguish a rated/measured limit from an estimate. Emitted only when set.

The plant-wide bottleneck, anyOverloaded, and anyHardLimitExceeded fields summarise the whole flowsheet. In a ProcessModel snapshot, a non-null bottleneck includes both its owning area and an unambiguous qualifiedName using the existing area::unit convention. Consumers should join or archive on qualifiedName, because separate process areas may legitimately reuse the same unit name. Because the snapshot reads constraints rather than re-solving, it is cheap to call on every optimization step.

Closed-loop RL pattern:

Compressors Without a Performance Chart

A compressor’s surge, stonewall, and speed constraints are only physically meaningful when a performance chart is active. Without a chart the compressor runs on a fixed outlet-pressure/polytropic-efficiency model where distance-to-surge is undefined (getDistanceToSurge() returns positive infinity), which would otherwise pin the surge utilization at a degenerate flat 100% that never responds to feed rate.

NeqSim therefore creates those chart-dependent constraints present but disabled for chartless compressors. The constraint objects still exist (so existence checks pass), but they are excluded from getMaxUtilization() and getBottleneckConstraint(). A chartless compressor consequently reports smooth, power-driven utilization. Give the power constraint a basis with:

compressor.getMechanicalDesign().setMaxDesignPower(installedKw); // kW

When a performance chart is later attached, call reinitializeCapacityConstraints() to re-enable the chart-dependent metrics.

Expanders (Turbo-Expanders)

Expander extends Compressor but operates in reverse — it produces shaft power and cools the gas. The inherited compressor capacity logic does not fit this: the consumed-power constraints (power, ratedPower) have no meaning for a power-producing machine, and Compressor.isSimulationValid() treats an expander’s normal operating state (negative shaft power, outlet colder than inlet, pressure ratio < 1) as invalid. Because Compressor.getMaxUtilization() returns a sentinel 1.5 whenever the simulation is flagged invalid with zero computed utilization, a healthy expander used to report a spurious ~150 % utilization.

Expander now fixes this natively by overriding two methods:

Set the rated recovered shaft power to get a meaningful utilization; otherwise the expander simply reports no spurious limit:

Expander expander = new Expander("X-100", feed);
expander.setOutletPressure(20.0);
expander.run();
expander.setRatedRecoveredPower(5000.0);   // kW — rebuilds the recoveredPower constraint
double util = expander.getMaxUtilization(); // |getPower| / 5000 kW, no spurious 150%

See Also