Documentation for specialized heat exchangers: WaterCooler for seawater/cooling water systems and ReBoiler for distillation column reboilers.

Table of Contents


Water Cooler

neqsim.process.equipment.heatexchanger.WaterCooler calculates cooling utility flow from the process duty and reference-water enthalpy rise. Fresh water is the default; setCoolingWaterSalinity(35.0) selects 35 g/kg solution seawater using IF97 water plus the IAPWS-08 saline Gibbs contribution. The process-side fluid retains its own thermodynamic and physical-property models.

Use setOutletTemperature(value, unit) for the process target and configure setWaterInletTemperature, setWaterOutletTemperature and setWaterPressure. The return temperature must exceed the supply temperature. Unsupported states, non-finite inputs and a heating duty are rejected. Mass-flow units and actual inlet-volume units are supported; standard gas-volume units are rejected.

See Reference water and seawater cooling for the complete compiled/executed Java example, two-stream HeatExchanger setup, plant-level CoolingWaterSystem sizing, equations, units and validity limits. A WATER physical-property enum does not by itself replace EOS heat capacity.


Reboiler

Location: neqsim.process.equipment.heatexchanger.ReBoiler

The ReBoiler class provides heat input to distillation column bottoms through enthalpy addition (PH flash calculation).

Features

Java Example

import neqsim.process.equipment.heatexchanger.ReBoiler;

// Get bottoms stream from column
Stream columnsBottoms = column.getBottomsStream();

// Create reboiler
ReBoiler reboiler = new ReBoiler("Reboiler", columnsBottoms);
reboiler.setReboilerDuty(500000.0);  // 500 kW in Watts

reboiler.run();

// Get outlet conditions
double outletTemp = reboiler.getOutletStream().getTemperature("C");
double vaporFraction = reboiler.getOutletStream().getFluid().getVaporFraction();

System.out.println("Reboiler outlet temperature: " + outletTemp + " °C");
System.out.println("Vapor fraction: " + vaporFraction);

Python Example

from neqsim import jneqsim

ReBoiler = jneqsim.process.equipment.heatexchanger.ReBoiler

# Create reboiler on column bottoms
reboiler = ReBoiler("Reboiler", column.getBottomsStream())
reboiler.setReboilerDuty(500000.0)  # Watts

reboiler.run()

outlet = reboiler.getOutletStream()
print(f"Outlet T: {outlet.getTemperature('C'):.1f} °C")
print(f"Vapor fraction: {outlet.getFluid().getVaporFraction():.3f}")

Calculation Method

The reboiler performs a PH flash:

  1. Calculate inlet enthalpy
  2. Add reboiler duty to enthalpy
  3. Flash at constant pressure to find outlet T and phase split
\[H_{out} = H_{in} + Q_{reboiler}\]

Integration with Distillation Column

// Create distillation column with reboiler
DistillationColumn column = new DistillationColumn("Debutanizer", 20, true, true);
column.addFeedStream(feedStream, 10);

// Access internal reboiler
Reboiler columnReboiler = column.getReboiler();
columnReboiler.setReboilerDuty(duty);

// Or use separate reboiler equipment
Stream bottoms = column.getLiquidOutStream();
ReBoiler externalReboiler = new ReBoiler("Thermosiphon", bottoms);
externalReboiler.setReboilerDuty(calculatedDuty);

API Reference

WaterCooler

Constructors

Constructor Description
WaterCooler(String name) Create cooler with name
WaterCooler(String name, StreamInterface inStream) Create with inlet stream

Configuration Methods

Method Description
setWaterInletTemperature(double, String) Set CW inlet temperature
setWaterOutletTemperature(double, String) Set CW outlet temperature
setWaterPressure(double, String) Set CW pressure
setOutTemperature(double, String) Set process outlet temperature

Results Methods

Method Description
getCoolingWaterFlowRate(String) Get CW flow rate (kg/hr, kg/sec, etc.)
getDuty() Get heat duty (W, negative for cooling)
getOutletStream() Get cooled process stream

ReBoiler

Constructors

Constructor Description
ReBoiler(String name, StreamInterface inStream) Create with inlet stream

Configuration Methods

Method Description
setReboilerDuty(double) Set heat input (Watts)

Results Methods

Method Description
getReboilerDuty() Get heat duty (Watts)
getOutletStream() Get heated outlet stream