LNG Liquefaction Process Models

NeqSim provides closed-loop screening models for four common LNG liquefaction routes in the neqsim.process.lng package. Each template uses the standard NeqSim equation-of-state flashes and unit operations, an LNGHeatExchanger for rigorous multi-stream temperature-enthalpy curves, and explicit Recycle units for refrigerant-loop convergence.

Supported routes

Cycle Template scope Main equipment
SMR Single mixed-refrigerant loop Two-stage MR compression, JT expansion, one MCHE
C3MR Single-level equivalent propane precooling plus mixed refrigerant Propane and MR compressor trains, precooler, MCHE
DMR Warm and cold mixed-refrigerant loops Two MR compressor trains, precooler, MCHE
NITROGEN_EXPANDER Closed reverse-Brayton nitrogen loop Two-stage N2 compression, turboexpander, MCHE

The C3MR template represents one equivalent propane evaporation level. It is appropriate for route screening and API examples; detailed design studies should model the actual three- or four-level propane cascade and optimize refrigerant inventories, pressure levels, and exchanger geometry.

Quick start

LNGProcessModel model = new LNGProcessBuilder()
    .setName("C3MR screening case")
    .setCycle(LNGProcessCycle.C3MR)
    .setFeedFlowRate(100000.0)
    .setFeedPressure(60.0)
    .setNumberOfZones(16)
    .setAdaptiveRefinement(true)
    .build();

LNGProcessModel.Result result = model.run();
double specificEnergy = result.getSpecificEnergyKWhPerKgLNG();
double lngYield = result.getLNGYield();
double minimumApproach = result.getMinimumInternalTemperatureApproachC();
LNGProcessBenchmark.Assessment benchmark = result.assessBenchmark();

Use setFeedFluid(SystemInterface) to clone a custom pretreated fluid into a standalone LNG feed. To connect a larger NeqSim simulation without copying its state, pass the live stream:

StreamInterface treatedGas = upstreamPipeline.getOutletStream();
LNGProcessModel connectedModel = new LNGProcessBuilder()
    .setName("Integrated LNG train")
    .setFeedStream(treatedGas)
    .setCycle(LNGProcessCycle.DMR)
    .build();

The stream reference remains live, so composition, flow, temperature, and pressure are supplied by the surrounding process. Refrigerant circulation is initialized from the live stream rate when build() is called. Rebuild or retune the refrigerant inventory after large feed-rate changes. Run a separate producing process before the LNG model, or use the shared-process form below. Acid gas, water, mercury, and heavy hydrocarbon removal must be represented upstream when those contaminants are present.

Professional integrated flowsheet

The route templates assume pretreated gas at the battery limit, but every piece of route equipment is explicit: compressor suction scrubbers, two-stage compressors, intercoolers and aftercoolers, refrigerant valves or an expander, multi-stream cryogenic exchangers, separators, and recycle tear streams. Pretreatment and fractionation can be assembled with the normal NeqSim unit operations and then extended in place:

ProcessSystem plant = new ProcessSystem("Professional LNG plant");

Stream richFeed = new Stream("Rich natural gas", richGasFluid);
richFeed.setFlowRate(30000.0, "kg/hr");
plant.add(richFeed);

PipeBeggsAndBrills inletPipeline =
    new PipeBeggsAndBrills("Feed-gas pipeline", richFeed);
inletPipeline.setLength(20000.0);
inletPipeline.setDiameter(0.40);
plant.add(inletPipeline);

DistillationColumn scrubColumn =
    new DistillationColumn("Heavy-hydrocarbon scrub column", 8, true, true);
scrubColumn.addFeedStream(inletPipeline.getOutletStream(), 4);
scrubColumn.setCondenserTemperature(-35.0, "C");
scrubColumn.setReboilerTemperature(65.0, "C");
plant.add(scrubColumn);

LNGProcessModel model = new LNGProcessBuilder()
    .setName("C3MR train")
    .setCycle(LNGProcessCycle.C3MR)
    .setUpstreamProcess(plant, scrubColumn.getGasOutStream())
    .build();

model.registerOutputStream("NGL", scrubColumn.getLiquidOutStream());
model.run();

StreamInterface lng = model.getOutputStream(LNGProcessModel.LNG_OUTPUT);
StreamInterface flashGas =
    model.getOutputStream(LNGProcessModel.FLASH_GAS_OUTPUT);
StreamInterface ngl = model.getOutputStream("NGL");

List<DistillationColumn> columns =
    model.getEquipment(DistillationColumn.class);
List<Compressor> compressors = model.getEquipment(Compressor.class);
List<Recycle> recycles = model.getEquipment(Recycle.class);

This makes the result behave like a professional process-simulation flowsheet: upstream pipeline hydraulics and columns, the complete refrigeration train, controls or measurements, and downstream product handling all remain in one ProcessSystem. getEquipment() returns the immutable flowsheet-order unit manifest, while getEquipment(Class) selects any NeqSim equipment type. The representative scrub column above separates an NGL bottoms stream; project models should add the required acid-gas removal, dehydration, mercury removal, NGL fractionation, and utility systems for the actual feed specification.

Common comparison metrics

LNGProcessModel.Result reports these metrics on the same basis for every route:

Output streams and downstream processing

Every output is a normal NeqSim StreamInterface and can feed other unit operations or process modules. The built-in named outputs are:

StreamInterface lng = model.getOutputStream(LNGProcessModel.LNG_OUTPUT);
StreamInterface flashGas =
    model.getOutputStream(LNGProcessModel.FLASH_GAS_OUTPUT);

PipeBeggsAndBrills lngPipeline =
    new PipeBeggsAndBrills("LNG transfer pipeline", lng);
model.addEquipment(lngPipeline);

Compressor flashGasCompressor =
    new Compressor("Flash gas compressor", flashGas);
model.addEquipment(flashGasCompressor);

getProductStream() remains a convenience alias for the liquid LNG stream, and getFlashGasStream() exposes the vapor directly. Use registerOutputStream(name, stream) to publish later route-specific or downstream products through the same registry.

Accuracy controls

The exchanger performs TP flashes at zone boundaries, applies per-stream pressure drops, and calculates composite curves, MITA, and zone exergy destruction. Adaptive refinement now scans every registered stream, so a phase transition on a refrigerant stream can refine the grid even when the natural-gas enthalpy curve is smooth.

For higher-fidelity studies:

  1. increase setNumberOfZones until MITA and specific energy are grid-independent;
  2. keep adaptive refinement enabled around refrigerant phase changes;
  3. set measured pressure drops for every exchanger passage;
  4. use the actual pretreated feed composition and an appropriate mixing rule;
  5. calibrate compressor and expander efficiencies; and
  6. optimize refrigerant composition, circulation rate, and pressure levels.

Speed controls

Adjacent exchanger zone flashes reuse one thermodynamic state and ThermodynamicOperations object per stream by default. This removes per-zone clone/allocation overhead and carries the previous converged state into the next flash. Use LNGHeatExchanger.setReuseZoneFlashState(false) for independent-zone regression comparisons.

The builder also enables process flash warm starts and optimized execution. For parameter studies, converge a base case before making small changes, and verify the fast configuration against a higher-zone reference case.

Integrated process and pipeline capacity

Use setUpstreamProcess(processSystem, feedStream) when inlet pipelines, pretreatment, fractionation, and the LNG train should execute as one ProcessSystem. The builder extends the supplied system in place. Standard NeqSim measurement devices, controllers, automation, optimization, mechanical design, cost, emissions, and reporting APIs remain available through model.getProcessSystem().

Downstream equipment can be appended directly. This example adds an LNG product pipeline and evaluates its hydraulic constraints together with every process equipment constraint:

ProcessSystem plant = new ProcessSystem("Integrated LNG plant");
// Add upstream pipelines and pretreatment to plant.
StreamInterface treatedGas = feedPipeline.getOutletStream();

LNGProcessModel model = new LNGProcessBuilder()
    .setName("LNG train")
    .setUpstreamProcess(plant, treatedGas)
    .setCycle(LNGProcessCycle.C3MR)
    .build();

PipeBeggsAndBrills productPipeline =
    new PipeBeggsAndBrills("LNG product pipeline", model.getProductStream());
productPipeline.setLength(15000.0);
productPipeline.setDiameter(0.50);
model.addEquipment(productPipeline);

LNGProcessModel.CapacityResult capacity =
    model.autoSizeAndEvaluateCapacity(1.20);
BottleneckResult bottleneck = capacity.getBottleneck();
Map<String, Double> rankedUtilization =
    capacity.getRankedUtilizationPercent();
String detailedSnapshot = capacity.getUtilizationSnapshotJson();

autoSizeAndEvaluateCapacity runs the integrated flowsheet, calls the standard plant-wide auto-sizing bridge, activates mechanical-design-derived constraints, reruns, and ranks all enabled constraints. For pipelines this can include velocity, pressure drop, volume flow, erosion/FIV, and other constraints provided by the selected pipeline and mechanical-design models. Compressors, exchangers, separators, valves, pumps, and other constrained equipment are ranked on the same basis.

For an existing design, set the actual mechanical design limits and call model.evaluateCapacity() after running instead of auto-sizing from the current operating point. The capacity snapshot is a constraint-utilization report; a maximum-throughput study should vary the live feed rate with the NeqSim optimization framework until the first hard or design constraint binds.

Literature comparison points

These are comparison points, not universal acceptance limits. Feed composition, ambient conditions, LNG flash definition, driver efficiency, and flowsheet complexity must match before interpreting deviations.

Cycle Reference specific energy (kWh/kg LNG) Source
SMR 0.2561 Pereira et al. (2022)
C3MR 0.2548 Pereira et al. (2022)
DMR 0.2456 Pereira et al. (2022)
Parallel nitrogen expansion 0.6180 He et al. (2019)

Pereira et al. compared optimized SMR, C3MR, DMR, and AP-X cases for the same 20,000 kg/h feed: Energy Conversion and Management 272 (2022) 116364.

The nitrogen reference is the optimized parallel nitrogen expansion case reported by He et al.: Energy 167 (2019) 1-12.

LNGProcessBenchmark.assess uses deliberately broad screening envelopes around these points and also checks product temperature, liquid yield, and temperature crosses. A passing screening result demonstrates physical plausibility on this basis; it does not replace project-specific validation against plant or licensor data.