Skip to the content.

Fouling thermal-hydraulic rating

ThermalDesignCalculator can represent a uniform deposit inside the tubes of an existing exchanger. HeatExchanger can use that geometry to calculate heat recovery and apply correlated pressure losses to its outlet streams. This supports the feed-preheater use case in issue #3718.

Define the two different fouling inputs

Input Thermal effect Hydraulic effect Area basis
setFoulingTube(resistance) Adds specified resistance None Nominal clean inner tube area
setTubeFoulingLayer(thicknessM, conductivityWmK) Cylindrical deposit conduction and changed film area Reduces bore, updates velocity, Reynolds number and pressure loss Deposit resistance getter reports nominal outside area
setFoulingShell(resistance) Adds specified resistance None Nominal outside tube area

The prescribed resistance and layer contributions are additive. Set the tube resistance to zero when the layer represents the same deposit; otherwise it would be counted twice. The existing nonzero default prescribed resistances remain unchanged. Setting layer thickness to zero restores the nominal bore. Setting a new thickness replaces the old thickness; repeated calculations do not accumulate deposits. Time evolution can be supplied externally, for example using calibrated FoulingModel resistances, but resistance alone does not determine thickness without conductivity.

For nominal inner and outer diameters $d_i,d_o$ (m), deposit thickness $\delta$ (m), and conductivity $k_f$ (W/(m K)), the effective bore is $d_f=d_i-2\delta$. The exact deposit resistance on the nominal outside area is:

\[R_{f,\mathrm{layer},o}=\frac{d_o}{2k_f}\ln\left(\frac{d_i}{d_f}\right)\]

The overall resistance is:

\[\frac{1}{U_o}=\frac{1}{h_o}+R_{f,o}+\frac{d_o}{2k_w}\ln\left(\frac{d_o}{d_i}\right)+\frac{d_o}{d_i}R_{f,i}+R_{f,\mathrm{layer},o}+\frac{d_o}{d_f h_i}\]

Here $h_i,h_o$ are film coefficients in W/(m² K), $k_w$ is metal conductivity in W/(m K), and all resistances after area conversion have units m² K/W. The metal wall and installed outside area remain unchanged. Tube friction uses the reduced bore and the existing smooth-tube Darcy correlation. No deposit roughness or shell-side blockage model is implied.

Apply the rating to a process

Configure the known geometry in a ThermalDesignCalculator, attach it with setRatingCalculator, and set setRatingArea(calculator.getOutsideHeatTransferArea()) for a geometrically consistent installed area. Then enable setUseRatingPressureDrop(true) before run() or ProcessSystem.run().

Stream 0 is the tube side; stream 1 is the shell side. Either can be the hotter stream. This mapping follows existing rating conventions and is independent of the builder’s hot/cold labels. For a cold tube feed and hot shell utility, construct the exchanger with the cold stream first.

The new option defaults to false. Existing thermal-only rating retains its inlet pressures. With the option enabled, each outlet pressure is its own inlet pressure minus its correlated pressure loss. An enthalpy flash at that outlet pressure conserves the heat duty and material inventory. Both outlet states are committed only after both flashes pass validation. Invalid pressure budgets, missing rating data, nonfinite properties, zero flows and multiphase states raise an exception. Fixed outlet-temperature and delta-T specifications are incompatible with this rating option.

The calculation uses inlet transport properties and heat-capacity rates obtained from enthalpy secants across the inlet temperature interval. It is a lumped single-phase rating, not a segmented two-phase model. The selected existing effectiveness relation is retained; the default is ideal counterflow. In particular, the legacy "shell and tube" label is a counterflow approximation, not a complete TEMA multipass thermal model. Use a more detailed model for temperature-dependent transport properties, phase change, maldistribution or detailed multipass design.

Rating recalculates when the process is rerun, including after mutation of its attached calculator. Pressure losses are always calculated from inlet pressure, so repeated runs do not compound them. The calculator remains transient in the exchanger’s serialization contract: reattach it after deserialization before using rating.

Validation and process interpretation

TubeDepositThermalDesignTest checks cylindrical resistance against radial conduction and laminar pressure losses against Hagen–Poiseuille plus the documented return losses at three thicknesses. It also checks the zero-deposit limit, resistance area basis, cleaning, repeated runs and blocked bores. HeatExchangerFoulingRatingTest checks pressure mapping, both directions of heat transfer, component/mass/enthalpy conservation, calculation identity, equal inlet temperatures and failure without committing outlet states.

A downstream Heater with a fixed outlet temperature quantifies the additional feed-heating duty caused by lower heat recovery. This is an energy requirement at the selected target state, not an independent prediction of distillation-column reboiler duty. A column model with fixed separation targets is required to make that further claim.

The inspiring paper is Soylu and Demirel (2025), Thermal-Hydraulic Analysis of a Shell-and-Tube Heat Exchanger Due to Fouling in the Distillation Process Using Aspen Plus, DOI 10.1115/1.4068191. Its complete geometry, fluid data and case inputs were not available during this implementation. The analytical checks and synthetic process demonstration are not a reproduction of its Aspen cases or an experimental validation.

The resistance derivation follows MIT’s cylindrical conduction notes and combined convection/conduction notes.