Mercury distribution studies in process simulation

Use this guide to find where the mercury of a well stream ends up in a process plant: how much goes with the gas, the oil and the water, what the mercury content of each product is, and where mercury comes out as a separate liquid or solid phase.

The study uses three parts:

Part Class What it does
Fluid MercuryFluidConverter Converts the study fluid, for example from an E300 file, to UMR-PRU-MC and gives it a mercury content
Process Separator.setFreeMercuryAccumulation Makes the separators hold back mercury that the fluid phases cannot dissolve
Report MercuryProcessAnalyzer Reports mercury in every stream and unit operation, and the mercury balance

The thermodynamic model, its parameters and its agreement with the mercury calculator are described in Mercury thermodynamics.

The fluid

Mercury is distributed with SystemUMRPRUMCEos and the mixing rule ("HV", "UNIFAC_UMRPRU"). A process study normally has a characterized fluid in an E300 file, read as a Peng-Robinson or SRK fluid. That model has no mercury parameters, so the fluid is converted:

SystemInterface e300Fluid = EclipseFluidReadWrite.read("fluid1.e300");
SystemInterface fluid = MercuryFluidConverter.toUmrPruMc(e300Fluid, 100.0, "ug/Sm3");

The conversion keeps the components and their amounts, temperature and pressure:

The mercury content refers to the whole fluid, in "mole fraction", "ppb", "ug/Sm3", "ug/Nm3" or "ug/kg". Mercury already in the fluid is replaced. toUmrPruMc(fluid) without a content keeps the mercury of the source fluid.

A measured mercury content normally refers to one phase of one stream, for example the gas from the inlet separator. Run the process once, read the calculated content of that phase from the report, and scale the content given to the converter by measured over calculated. Below saturation mercury distributes in proportion to the feed content, so one correction is enough. Check it with a second run.

Add water before the conversion if the E300 fluid has none: EclipseFluidReadWrite.read(file, true) adds the water component, and fluid.addComponent("water", moles) sets its amount.

How close the converted fluid is

The converted fluid is close to the E300 fluid, not identical. Checked on 2026-11-19 for a Peng-Robinson oil with 12 pseudo-components (fluid1.e300) and 5 mol% water, in a process with inlet separation at 70 C and 60 bara, a second stage at 5 bara, recompression and a cold separator at -40 C:

Quantity UMR-PRU-MC relative to the E300 fluid
Gas and oil mass flow from the separators -1.6 % to +1.4 %
Water mass flow from the inlet separator -6.5 %
Gas density +0.3 % to +0.6 %
Oil density +3 % to +11 %
Water density +7 %

Use the mercury flows and the contents per mass or per standard volume. Take volume flows and liquid densities from the E300 model. Compare the main stream flows of the two models in every study and report the differences.

Running the process

Build the process with the converted fluid in the same way as with the E300 fluid, switch on free mercury accumulation and run it:

ProcessSystem process = new ProcessSystem();
Stream feed = new Stream("feed", fluid);
feed.setFlowRate(200000.0, "kg/hr");
feed.setTemperature(70.0, "C");
feed.setPressure(60.0, "bara");
process.add(feed);
Separator inletSeparator = new Separator("inlet separator", feed);
process.add(inletSeparator);
Cooler chiller = new Cooler("chiller", inletSeparator.getGasOutStream());
chiller.setOutTemperature(273.15 - 40.0);
process.add(chiller);
Separator coldSeparator = new Separator("cold separator", chiller.getOutletStream());
process.add(coldSeparator);

MercuryProcessAnalyzer.setFreeMercuryAccumulation(process, true);
process.run();

MercuryProcessReport report = MercuryProcessAnalyzer.analyze(process);
for (MercuryStreamResult stream : report.getStreams()) {
  String name = stream.getLabel();
  double gramPerDay = stream.getMercuryFlowRate("g/day");
  double saturation = stream.getSaturationRatio(); // above 1: the stream carries free mercury
  String state = stream.getFreeMercuryState(); // "none", "liquid" or "solid"
  double gasContent = stream.getMercuryConcentration("gas", "ug/Sm3"); // NaN without a gas phase
}
double heldBack = coldSeparator.getFreeMercuryAccumulationRate("g/day");
String heldBackState = coldSeparator.getFreeMercuryState();
double notAccountedFor = report.getMercuryBalanceError("g/day");
String json = report.toJson();
from neqsim import jneqsim

e300_fluid = jneqsim.thermo.util.readwrite.EclipseFluidReadWrite.read("fluid1.e300")
fluid = jneqsim.thermo.util.mercury.MercuryFluidConverter.toUmrPruMc(e300_fluid, 100.0, "ug/Sm3")

process = build_process(fluid)  # the same function that builds the process for the E300 fluid
analyzer = jneqsim.process.util.mercury.MercuryProcessAnalyzer
analyzer.setFreeMercuryAccumulation(process, True)
process.run()

report = analyzer.analyze(process)
for stream in report.getStreams():
    print(stream.getLabel(), stream.getMercuryFlowRate("g/day"), stream.getSaturationRatio(),
          stream.getFreeMercuryState(), stream.getMercuryConcentration("gas", "ug/Sm3"))
print(report.toJson())

Build the process again with the converted fluid. Do not replace the fluid of the feed streams in a process that is already built: recycle streams and other units keep copies of the first fluid.

For a plant with several process areas, pass the ProcessModel to analyze and setFreeMercuryAccumulation.

From a JSON process definition

The JSON process builder converts an E300 fluid when the model is UMRPRU, and separators take the option as a property:

{
  "fluid": {
    "e300FilePath": "fluid1.e300",
    "model": "UMRPRU",
    "mercuryContent": [100.0, "ug/Sm3"],
    "temperature": 333.15,
    "pressure": 60.0
  },
  "process": [
    {"type": "Stream", "name": "feed", "properties": {"flowRate": [200000.0, "kg/hr"]}},
    {"type": "Separator", "name": "inlet separator", "inlet": "feed",
     "properties": {"freeMercuryAccumulation": true}}
  ]
}

A fluid given by components uses "model": "UMRPRU" with "mercury" among the components. The model now gets the UMR-PRU mixing rule by default; before, the JSON builder and the MCP runners gave it the classic mixing rule, which does not use the group parameters.

Free mercury

A stream carries free mercury when it holds more mercury than its gas, oil and aqueous phases dissolve. This happens when a stream is cooled, and also when gas is compressed and cooled or when oil is flashed to lower pressure. Free mercury is liquid above 234.321 K (-38.83 C) and solid below.

In the report. Every stream has a saturation ratio: the fugacity of mercury with all mercury dissolved divided by the fugacity of pure liquid or solid mercury. Below one all mercury is dissolved. Above one the report gives the state and the flow of free mercury, and the content of each phase at saturation. Free mercury below 0.1 % of the mercury in a stream is not reported, since a stream that leaves a separator saturated shows such amounts when it is flashed again.

In the process. Without free mercury accumulation the process calculation has no separate mercury phase. A stream above saturation then keeps too much mercury in the gas and oil, or the flash forms a mercury-rich liquid that leaves with one of the liquid outlets. With setFreeMercuryAccumulation(true) a separator calculates the separate mercury phase with MercuryPhaseEquilibrium, holds that mercury back and lets the gas and liquids leave saturated. The rate is read with getFreeMercuryAccumulationRate(unit) and is included in the mass balance of the separator.

The option works in Separator, GasScrubber, TwoPhaseSeparator, ThreePhaseSeparator, ThreePhaseGasScrubber and separators that use their steady-state calculation. Free mercury that forms in a cooler, a valve or a compressor aftercooler follows the stream to the next separator. Place a separator where mercury is expected to settle, or read the free mercury of the stream from the report.

The option is off by default, and a separator then does no mercury calculation. Ordinary simulations give the same results at the same speed. Measured on 2026-11-19 on a separation and recompression process with 13 units and an SRK fluid, as the fastest of 24 batches of 25 runs in three repetitions: 17.1 to 17.7 ms per run before this functionality and 17.2 to 17.8 ms after it with multiphase check, and 15.5 to 16.2 ms before and 15.1 to 16.6 ms after without. The difference is within the variation between repetitions. When the option is on and the fluid has no mercury, or dissolves all of it, the separator keeps its ordinary result.

Example

A wet gas-condensate with $5 \cdot 10^{-8}$ mole fraction mercury is separated at 60 C and 60 bara. The oil is flashed to 8 bara and its gas recompressed. The gas is cooled to 25 C, chilled to -45 C in a dew point control separator and compressed for export. MercuryProcessAnalyzerTest holds the case.

Stream Mercury, g/day Saturation ratio Free mercury
Feed 902 0.03 none
Gas from the inlet separator 443 0.03 none
Oil from the second stage 379 0.05 none
Gas after the gas cooler, 25 C 478 0.33 none
Gas after the chiller, -45 C 413 72 solid, 407 g/day
Export gas, separators hold back free mercury 0.96 0.001 none
Export gas, without free mercury accumulation 69.5 0.07 none

The cold separator holds back 407 g/day of solid mercury, and the export gas holds 0.67 ug/Sm3. Without free mercury accumulation the same calculation sends 72 times more mercury to export than the gas dissolves at -45 C.

Limits

Agent and skill

The mercury-distribution agent runs this workflow from an E300 fluid and a process model, and the neqsim-mercury-distribution-study skill holds the steps and checks.