Flow Rate Optimization

New to process optimization? Start with the Optimization Overview to understand when to use which optimizer.

This guide covers the FlowRateOptimizer class for calculating optimal flow rates given pressure boundary conditions and generating lift curve tables for Eclipse reservoir simulation.

Document Description
Optimization Overview When to use which optimizer
Constraint Framework Unified constraint system for all optimizers
Optimizer Plugin Architecture ProcessOptimizationEngine and VFP export
Production Optimization Guide ProductionOptimizer examples

Overview

The FlowRateOptimizer is designed to solve a common production optimization problem:

Given inlet and outlet pressure constraints, what is the maximum achievable flow rate?

This is essential for:

Key Features

Feature Description
Pressure boundary search Find max flow at given inlet/outlet pressures
Lift curve tables 2D tables for Eclipse VFP/VFPPROD keywords
Capacity curves 1D curves at fixed inlet pressure
Compressor constraints Surge, stonewall, power, speed limits
Reservoir coupling Requires VFP axis, datum, and unit conversion with EclipseVFPExporter
JSON export Machine-readable results for external tools

Table of Contents


Quick Start

Java code blocks are method bodies using the imports from the first example; place statements in main(String[] args) throws Exception. Later sections reuse that process and optimizer, with repeated local names in separate scopes. Python blocks run in order in a session with neqsim, numpy, and matplotlib installed.

Basic Flow Rate Calculation

Java output uses Log4j2. Declare this field inside your example class: private static final org.apache.logging.log4j.Logger logger = org.apache.logging.log4j.LogManager.getLogger("OptimizationExample");.

import neqsim.process.equipment.compressor.Compressor;
import neqsim.process.equipment.stream.Stream;
import neqsim.process.processmodel.ProcessSystem;
import neqsim.process.util.optimizer.FlowRateOptimizer;
import neqsim.thermo.system.SystemSrkEos;

// Create process
SystemSrkEos gas = new SystemSrkEos(288.15, 50.0);
gas.addComponent("methane", 0.85);
gas.addComponent("ethane", 0.10);
gas.addComponent("propane", 0.05);
gas.setMixingRule("classic");

Stream feed = new Stream("Feed", gas);
feed.setFlowRate(50000, "kg/hr");
feed.setPressure(50.0, "bara");

Compressor comp = new Compressor("Export Compressor", feed);
comp.setOutletPressure(100.0);

ProcessSystem process = new ProcessSystem();
process.add(feed);
process.add(comp);
process.run();

// Create optimizer
FlowRateOptimizer optimizer = new FlowRateOptimizer(process, "Feed", "Export Compressor");
optimizer.setMinFlowRate(25000.0); // kg/hr: bracket the known design point
optimizer.setMaxFlowRate(100000.0);
optimizer.setMinSurgeMargin(0.15);  // 15% surge margin
optimizer.setMaxPowerLimit(5000.0); // 5 MW max
optimizer.configureProcessCompressorCharts();

// Find max flow rate
FlowRateOptimizer.ProcessOperatingPoint result =
    optimizer.findMaxFlowRateAtPressureBoundaries(50.0, 100.0, "bara", 0.95);

if (result != null && result.isFeasible()) {
    logger.info("Max flow rate: " + result.getFlowRate() + " kg/hr");
    logger.info("Total power: " + result.getTotalPower() + " kW");
}

Lift Curve Generation

Process Capacity Table

Generate a 2D table of operating points for multiple inlet/outlet pressure combinations:

// Define pressure grid
double[] inletPressures = {40.0, 50.0, 60.0, 70.0, 80.0};      // bara
double[] outletPressures = {90.0, 100.0, 110.0, 120.0, 130.0}; // bara

// Generate table (sequential by default)
FlowRateOptimizer.ProcessCapacityTable table =
    optimizer.generateProcessCapacityTable(
        inletPressures,
        outletPressures,
        "bara",
        0.95  // max utilization
    );

// Inspect the capacity report (not a reservoir VFP deck)
String capacityReport = table.toFormattedString();
logger.info(capacityReport);

Parallel Lift Curve Generation

For large pressure grids, enable parallel evaluation to speed up generation:

// Enable parallel evaluation for faster lift curve generation
optimizer.setEnableParallelEvaluation(true);
optimizer.setParallelThreads(4);  // Use 4 threads (default: CPU count)

// Generate table in parallel - each pressure combination evaluated concurrently
FlowRateOptimizer.ProcessCapacityTable table =
    optimizer.generateProcessCapacityTable(
        inletPressures,   // e.g., 10 inlet pressures
        outletPressures,  // e.g., 10 outlet pressures = 100 evaluations
        "bara",
        0.95
    );

Notes on parallel evaluation:

Export and Access Results

// Export to JSON
String json = table.toJson();

// Get specific operating point
FlowRateOptimizer.ProcessOperatingPoint point = table.getOperatingPoint(1, 2);
if (point != null && point.isFeasible()) {
    logger.info("Flow at Pin=50, Pout=110: " + point.getFlowRate() + " kg/hr");
}

Capacity Tables and Eclipse VFP Tables

A capacity table gives maximum mass flow for imposed inlet/outlet pressures. It is not a reservoir VFP table. Both ProcessCapacityTable.toEclipseFormat() and ProcessLiftCurveTable.toEclipseFormat() now throw UnsupportedOperationException: process outlet pressure does not establish well BHP, and kg/hr is not a standard phase-volume rate.

Use toJson(), toCsv(), or toFormattedString() for capacity screening. For reservoir coupling, generate physically defined BHP values on the prescribed flow/THP/water-fraction/gas-fraction/artificial-lift axes and pass them to EclipseVFPExporter. Set its unit system and flow-rate type explicitly; its input contract defaults to Sm3/day and bara, and converts to the selected METRIC/FIELD deck units. It does not infer phase volumes from kg/hr. See the VFP export contract for units, supported axes and migration. See VFP export configuration for the exporter API and pressure boundary optimization for solving the process boundary problem.


Professional Lift Curve Generation

Use LiftCurveConfiguration to collect capacity, pressure-flow, and performance tables with a common configuration. These are model screening results; replace auto-generated compressor charts with validated equipment data for plant studies:

// Configure lift curve generation
FlowRateOptimizer.LiftCurveConfiguration config =
    new FlowRateOptimizer.LiftCurveConfiguration()
        .withInletPressureRange(40, 80, 5)    // min, max, number of points
        .withOutletPressureRange(90, 120, 4)  // min, max, number of points
        .withPressureUnit("bara")
        .withFlowRateUnit("kg/hr")
        .withMaxUtilization(0.95)
        .withSurgeMargin(0.15)
        .withMaxPowerLimit(5000.0)
        .withTables(true, true, true);        // capacity, lift curve, performance

// Generate professional lift curves
FlowRateOptimizer.LiftCurveResult result =
    optimizer.generateProfessionalLiftCurves(config);

// Get the capacity report
logger.info(result.getCapacityTable().toFormattedString());

// Check for warnings
for (String warning : result.getWarnings()) {
    logger.info("Warning: " + warning);
}

// Get statistics
logger.info("Total evaluations: " + result.getTotalEvaluations());
logger.info("Feasible points: " + result.getFeasiblePoints());
logger.info("Generation time: " + result.getGenerationTimeMs() + " ms");

Constraint Configuration

Compressor Constraints

// Set surge margin
optimizer.setMinSurgeMargin(0.15);      // 15% minimum surge margin

// Set power limits
optimizer.setMaxPowerLimit(5000.0);        // Per compressor limit (kW)
optimizer.setMaxTotalPowerLimit(15000.0);  // Total system power limit (kW)

// Set speed limits (absolute RPM)
optimizer.setMinSpeedLimit(7000.0);     // Minimum speed (RPM)
optimizer.setMaxSpeedLimit(10500.0);    // Maximum speed (RPM)

// Configure compressor charts automatically
optimizer.configureProcessCompressorCharts();

Equipment Utilization Limits

// Set overall max equipment utilization (applies to all equipment)
optimizer.setMaxEquipmentUtilizationLimit(0.95);  // 95% max for all equipment

Performance Tables

Process Performance Table

Generate a table showing performance at different flow rates:

double[] flowRates = {30000, 50000, 70000, 90000, 110000};  // kg/hr

FlowRateOptimizer.ProcessPerformanceTable perfTable =
    optimizer.generateProcessPerformanceTable(
        flowRates,
        "kg/hr",
        60.0,    // inlet pressure
        "bara"
    );

// Print formatted table
logger.info(perfTable.toFormattedString());

// Get data programmatically
for (int i = 0; i < flowRates.length; i++) {
    FlowRateOptimizer.ProcessOperatingPoint pt = perfTable.getOperatingPoint(i);
    logger.info(String.format("Flow: %.0f kg/hr, Power: %.0f kW, Feasible: %b%n",
        pt.getFlowRate(), pt.getTotalPower(), pt.isFeasible()));
}

Compressor Operating Point Data

Each ProcessOperatingPoint includes detailed compressor data:

FlowRateOptimizer.ProcessOperatingPoint point =
    optimizer.findMaxFlowRateAtPressureBoundaries(50.0, 100.0, "bara", 0.95);

// Get compressor details
if (point == null) {
    throw new IllegalStateException("No feasible compressor point at these boundaries");
}
for (String compName : point.getCompressorNames()) {
    FlowRateOptimizer.CompressorOperatingPoint cop =
        point.getCompressorOperatingPoint(compName);

    logger.info("Compressor: " + compName);
    logger.info("  Power: " + cop.getPower() + " kW");
    logger.info("  Speed: " + cop.getSpeed() + " RPM");
    logger.info("  Flow: " + cop.getFlowRate() + " " + cop.getFlowRateUnit());
    logger.info("  Head: " + cop.getPolytropicHead() + " kJ/kg");
    logger.info("  Surge margin: " + cop.getSurgeMargin() * 100 + "%");
    logger.info("  At stonewall: " + cop.isAtStoneWall());
}

Operating Modes

The FlowRateOptimizer supports two operating modes:

1. PROCESS_SYSTEM Mode (Default)

For ProcessSystem objects with compressors:

FlowRateOptimizer systemOptimizer =
    new FlowRateOptimizer(process, "Feed", "Export Compressor");

2. PROCESS_MODEL Mode

For ProcessModel objects:

neqsim.process.processmodel.ProcessModel processModel =
    new neqsim.process.processmodel.ProcessModel();
processModel.add("export", process);
FlowRateOptimizer modelOptimizer =
    new FlowRateOptimizer(processModel, "Feed", "Export Compressor");

Pipe-Only Pressure-Drop Calculations

For pressure-drop calculations, construct a pipe process. There is no no-argument constructor, Mode.SIMPLE, or setMode() method.

// A pipe-only calculation still uses PROCESS_SYSTEM mode.
Stream pipeFeed = new Stream("Pipe Feed", gas.clone());
pipeFeed.setFlowRate(10000.0, "kg/hr");
neqsim.process.equipment.pipeline.PipeBeggsAndBrills pipe =
    new neqsim.process.equipment.pipeline.PipeBeggsAndBrills("Pipeline", pipeFeed);
pipe.setLength(10000.0);
pipe.setDiameter(0.20);
ProcessSystem pipeSystem = new ProcessSystem();
pipeSystem.add(pipeFeed);
pipeSystem.add(pipe);
pipeSystem.run();
FlowRateOptimizer pipeOptimizer = new FlowRateOptimizer(pipeSystem, "Pipe Feed", "Pipeline");
pipeOptimizer.setMinFlowRate(1000.0);
pipeOptimizer.setMaxFlowRate(100000.0);
neqsim.process.util.optimizer.FlowRateOptimizationResult pipeResult =
    pipeOptimizer.findFlowRate(50.0, 45.0, "bara");

Validation

Validate optimizer configuration before running:

List<String> issues = optimizer.validateConfiguration();
if (!issues.isEmpty()) {
    logger.info("Configuration issues:");
    for (String issue : issues) {
        logger.info("  - " + issue);
    }
} else {
    logger.info("Configuration valid, ready to optimize");
}

JSON Export

Export results in JSON format for integration with external tools:

// Table JSON is available directly.
String tableJson = table.toJson();
// Individual operating points and LiftCurveResult have no toJson() method.
// Gson serializes their data fields; permit undefined diagnostic values explicitly.
com.google.gson.Gson gson = new com.google.gson.GsonBuilder()
    .serializeSpecialFloatingPointValues().create();
String pointJson = gson.toJson(point);
String resultJson = gson.toJson(result);

Example JSON output:

{
  "tableName": "Export_System_VFP",
  "pressureUnit": "bara",
  "flowRateUnit": "kg/hr",
  "maxUtilization": 0.95,
  "inletPressures": [40.0, 50.0, 60.0, 70.0, 80.0],
  "outletPressures": [90.0, 100.0, 110.0, 120.0],
  "operatingPoints": [
    {
      "inletPressure": 40.0,
      "outletPressure": 90.0,
      "flowRate": 45000.0,
      "totalPower": 3200.0,
      "feasible": true,
      "compressors": {
        "Export Compressor": {
          "power": 3200.0,
          "speed": 9500.0,
          "surgeMargin": 0.18
        }
      }
    }
  ]
}

Best Practices

1. Configure Compressor Charts

// Before optimization
optimizer.configureProcessCompressorCharts();

Auto-generated curves approximate the design operating point. They are educational fixtures, not vendor surge/stonewall evidence.

2. Use Appropriate Surge Margins

Application Recommended Surge Margin
Steady-state operations 10-15%
Transient operations 15-20%
Start-up/shutdown 20-25%

3. Validate Before Running

List<String> issues = optimizer.validateConfiguration();
if (!issues.isEmpty()) {
    throw new IllegalStateException("Invalid configuration: " + issues);
}

4. Handle Infeasible Points

FlowRateOptimizer.ProcessOperatingPoint candidate =
    optimizer.findMaxFlowRateAtPressureBoundaries(50.0, 100.0, "bara", 0.95);
if (candidate == null || !candidate.isFeasible()) {
    logger.info("No feasible operating point found; inspect constraint diagnostics");
}

Troubleshooting

No Feasible Points Found

  1. Check compressor charts are configured
  2. Verify pressure ranges are achievable
  3. Check power/speed limits aren’t too restrictive
  4. Try relaxing surge margin temporarily

Slow Performance

  1. Reduce pressure grid resolution
  2. Increase convergence tolerance
  3. Use fewer iterations for initial exploration

Eclipse Export Issues

  1. Verify flow rates are in expected units
  2. Check pressure monotonicity
  3. Ensure at least 2 feasible points per curve

Python Usage (via JPype)

All FlowRateOptimizer functionality is accessible from Python using neqsim-python and JPype.

Basic Setup

from neqsim.neqsimpython import jneqsim
import numpy as np

# Import classes
ProcessSystem = jneqsim.process.processmodel.ProcessSystem
Stream = jneqsim.process.equipment.stream.Stream
Compressor = jneqsim.process.equipment.compressor.Compressor
Cooler = jneqsim.process.equipment.heatexchanger.Cooler
SystemSrkEos = jneqsim.thermo.system.SystemSrkEos

FlowRateOptimizer = jneqsim.process.util.optimizer.FlowRateOptimizer

Creating a Process and Optimizer

# Create gas composition
gas = SystemSrkEos(288.15, 50.0)
gas.addComponent("methane", 0.85)
gas.addComponent("ethane", 0.10)
gas.addComponent("propane", 0.05)
gas.setMixingRule("classic")

# Build process
feed = Stream("Feed", gas)
feed.setFlowRate(50000, "kg/hr")
feed.setPressure(50.0, "bara")

compressor = Compressor("Export Compressor", feed)
compressor.setOutletPressure(100.0)

afterCooler = Cooler("Aftercooler", compressor.getOutletStream())
afterCooler.setOutTemperature(313.15)  # 40°C

process = ProcessSystem()
process.add(feed)
process.add(compressor)
process.add(afterCooler)
process.run()

# Create optimizer
optimizer = FlowRateOptimizer(process, "Feed", "Export Compressor")
optimizer.setMinFlowRate(25000.0)  # kg/hr: bracket the known design point
optimizer.setMaxFlowRate(100000.0)
optimizer.setMinSurgeMargin(0.15)  # 15% surge margin
optimizer.setMaxPowerLimit(5000.0)  # 5 MW max
optimizer.configureProcessCompressorCharts()

Finding Maximum Flow Rate

# Find max flow at pressure boundaries
result = optimizer.findMaxFlowRateAtPressureBoundaries(
    50.0,    # inlet pressure (bara)
    100.0,   # outlet pressure (bara)
    "bara",  # pressure unit
    0.95     # max utilization
)

if result is not None and result.isFeasible():
    print(f"Max flow rate: {result.getFlowRate():.0f} kg/hr")
    print(f"Total power: {result.getTotalPower():.1f} kW")
    print(f"Feasible: {result.isFeasible()}")
else:
    print("No feasible operating point found")

Generating Lift Curve Tables

import numpy as np

# Define pressure grids
inlet_pressures = [40.0, 50.0, 60.0, 70.0, 80.0]     # bara
outlet_pressures = [90.0, 100.0, 110.0, 120.0, 130.0]  # bara

# Convert to Java arrays (required for JPype)
from jpype import JArray, JDouble
java_inlet = JArray(JDouble)(inlet_pressures)
java_outlet = JArray(JDouble)(outlet_pressures)

# Generate lift curve table
table = optimizer.generateProcessCapacityTable(
    java_inlet,
    java_outlet,
    "bara",
    0.95  # max utilization
)

# Inspect the capacity report
capacity_report = table.toFormattedString()
print(capacity_report)

# Export to JSON
json_output = table.toJson()

# Access individual operating points
point = table.getOperatingPoint(1, 2)  # Pin=50, Pout=110
if point is not None and point.isFeasible():
    print(f"Flow at Pin=50, Pout=110: {point.getFlowRate():.0f} kg/hr")
else:
    print("This pressure pair has no feasible operating point")

Parallel Lift Curve Generation

# Enable parallel evaluation for large tables
optimizer.setEnableParallelEvaluation(True)
optimizer.setParallelThreads(4)  # Use 4 threads

# Generate table in parallel
table = optimizer.generateProcessCapacityTable(
    java_inlet,
    java_outlet,
    "bara",
    0.95
)

print(f"Feasible points: {table.countFeasiblePoints()}")

Professional Lift Curves with Configuration

# Create configuration object
LiftCurveConfiguration = FlowRateOptimizer.LiftCurveConfiguration

config = LiftCurveConfiguration() \
    .withInletPressureRange(40, 80, 5) \
    .withOutletPressureRange(90, 120, 4) \
    .withPressureUnit("bara") \
    .withFlowRateUnit("kg/hr") \
    .withMaxUtilization(0.95) \
    .withSurgeMargin(0.15) \
    .withMaxPowerLimit(5000.0) \
    .withTables(True, True, True)

# Generate professional lift curves
result = optimizer.generateProfessionalLiftCurves(config)

# Get the capacity report
print(result.getCapacityTable().toFormattedString())

# Check warnings
for warning in result.getWarnings():
    print(f"Warning: {warning}")

Processing Results in Python

import json

# Parse JSON results for pandas/numpy analysis
json_str = table.toJson()
data = json.loads(str(json_str))

# Extract flow rates into numpy array
import numpy as np
flow_matrix = np.zeros((len(inlet_pressures), len(outlet_pressures)))

for i, pin in enumerate(inlet_pressures):
    for j, pout in enumerate(outlet_pressures):
        point = table.getOperatingPoint(i, j)
        if point is not None and point.isFeasible():
            flow_matrix[i, j] = point.getFlowRate()
        else:
            flow_matrix[i, j] = np.nan

print("Flow rate matrix (kg/hr):")
print(flow_matrix)

Plotting Lift Curves (matplotlib)

import matplotlib.pyplot as plt
import numpy as np

# Collect data for plotting
fig, ax = plt.subplots(figsize=(10, 6))

for i, pin in enumerate(inlet_pressures):
    flows = []
    pressures = []
    for j, pout in enumerate(outlet_pressures):
        point = table.getOperatingPoint(i, j)
        if point is not None and point.isFeasible():
            flows.append(point.getFlowRate())
            pressures.append(pout)

    if flows:
        ax.plot(flows, pressures, 'o-', label=f'Pin={pin} bara')

ax.set_xlabel('Flow Rate (kg/hr)')
ax.set_ylabel('Outlet Pressure (bara)')
ax.set_title('Lift Curves - Export Compression System')
ax.legend()
ax.grid(True)
plt.savefig('lift_curves.png', dpi=150)
plt.show()


API Reference

FlowRateOptimizer

Method Description
findMaxFlowRateAtPressureBoundaries() Find max flow for pressure boundaries
generateProcessCapacityTable() Generate 2D lift curve table
generateProcessPerformanceTable() Generate 1D performance table
generateProfessionalLiftCurves() Generate configured screening tables
configureProcessCompressorCharts() Auto-configure compressor charts
validateConfiguration() Validate optimizer setup
findProcessOperatingPoint() Find operating point at specific flow

ProcessCapacityTable

Method Description
toEclipseFormat() Deprecated diagnostic alias on LiftCurveTable; rejected for process capacity/lift tables
toJson() Export to JSON
getOperatingPoint(i, j) Get point at grid indices
countFeasiblePoints() Count of feasible points

ProcessOperatingPoint

Method Description
getFlowRate() Flow rate value
getTotalPower() Total compressor power
isFeasible() Feasibility status
getCompressorOperatingPoint() Detailed compressor data
toJson() Export table data to JSON