This guide explains how to export an existing NeqSim ProcessSystem or multi-area ProcessModel to JSON, run it through the JSON builder or MCP runner, and keep parity when the base fluid was characterized from Eclipse E300 data.

Use this page when you already have a working process model in Java or Python and want a durable JSON artifact for MCP, web APIs, regression tests, or agent workflows. For hand-written builder input, see JSON Format for ProcessSystem and ProcessModel.

Why E300 Needs Special Treatment

An E300 fluid is not only a component list and a composition. It can carry pseudo-component and plus-fraction data that affects density, liquid volume, and phase behavior:

Data item Why it matters in JSON replay
Critical temperature and pressure Rebuilds the EoS component parameters for TBP and plus fractions
Acentric factor and optional OmegaA override Preserves cubic EoS alpha behavior for characterized components
Molecular weight and normal liquid density Preserves material balance, oil density, and volume rates
Critical volume, Rackett Z, parachor Preserves liquid-density and surface-property behavior where available
Volume-correction flag and constants Preserves Peneloux/E300 volume-shift behavior and oil export volume rates
Binary interaction parameters Preserves tuned phase behavior when non-default BIPs are present

If JSON only stores component names and mole fractions, mass rates can still match while volume rates drift. This is most visible on oil export and stable-liquid streams where density depends on volume correction and characterized pseudo-components.

Export Modes

NeqSim supports two E300-related JSON modes.

Mode JSON field Best use Portability
Path-based import fluid.e300FilePath Local builder jobs where the E300 file is available on disk Depends on local file path
Self-contained export componentProperties, useVolumeCorrection, BIPs MCP, APIs, task artifacts, and model exchange Portable JSON, no E300 file needed

The exporter uses the self-contained mode. It writes an E300-equivalent property snapshot for each fluid in the process JSON. It does not need the original E300 file path once the fluid has been loaded into NeqSim.

The current process JSON export includes non-zero scalar EoS binary interaction parameters as binaryInteractionParameters entries with comp1, comp2, and kij. It does not yet serialize temperature-dependent BIP terms such as kijT1 or asymmetric ij/ji mixing-rule matrices.

  1. Build and run the original process model until it represents the accepted live case.
  2. For multi-area plants, use ProcessModel and add process areas in upstream-to-downstream order.
  3. Set the intended execution mode on the ProcessModel before export:
    • runStep = false for MCP run-to-convergence.
    • runStep = true only for one-pass diagnostic snapshots.
  4. Set outer convergence controls on the ProcessModel when the model needs values different from the defaults:
    • maxIterations
    • flowTolerance
    • temperatureTolerance
    • pressureTolerance
  5. Export JSON from the live model.
  6. Check that E300-equivalent fluid fields are present.
  7. Rebuild or run through MCP.
  8. Compare mass rates, standard gas rates, liquid volume rates, and convergence summary against the original case.

What toJson() Exports

For a ProcessSystem, toJson() writes one JSON object with a default fluid, optional named fluids, and a process array. For a ProcessModel, toJson() writes a top-level areas object where each area is a ProcessSystem JSON object.

Key top-level fields for ProcessModel are:

Field Meaning
type ProcessModel
name Process model name
areas Named ProcessSystem JSON definitions
interAreaLinks Live stream references crossing process-system boundaries
runStep Whether MCP or import should run one step or iterate to convergence
maxIterations Outer ProcessModel iteration limit
flowTolerance Relative boundary-flow convergence tolerance
temperatureTolerance Relative boundary-temperature convergence tolerance
pressureTolerance Relative boundary-pressure convergence tolerance

E300-Equivalent Fluid Fields

The exporter writes full component properties for all exported fluids, including default fluids, named stream fluids, and materialized boundary-stream fluids.

Expected fluid fields include:

{
  "model": "PR",
  "temperature": 304.15,
  "pressure": 55.0,
  "mixingRule": "classic",
  "useVolumeCorrection": true,
  "components": {
    "methane": 0.35
  },
  "characterizedComponents": [
    {
      "name": "C7",
      "moleFraction": 0.65,
      "molarMass": 0.2,
      "density": 0.84,
      "Tc": 650.0,
      "Pc": 25.0,
      "acentricFactor": 0.85,
      "volumeCorrection": 0.0456,
      "volumeShift": 0.0456
    }
  ],
  "componentProperties": [
    {
      "name": "methane",
      "moleFraction": 0.35,
      "molarMass": 0.01604,
      "Tc": 190.56,
      "Pc": 45.99,
      "acentricFactor": 0.011,
      "volumeCorrection": 0.0123,
      "omegaA": 0.45724
    }
  ]
}

The builder applies componentProperties after recreating the base fluid. This is what preserves E300-like pseudo-component and volume-correction behavior without needing e300FilePath.

Stream-Specific Fluids and Feed Compositions

Large process models often contain multiple feed streams with different compositions or fluids. The exporter gives explicit stream units their own named fluid reference:

{
  "fluids": {
    "oil_feed_fluid": {
      "model": "PR",
      "useVolumeCorrection": true,
      "componentProperties": []
    }
  },
  "process": [
    {
      "type": "Stream",
      "name": "oil feed",
      "fluidRef": "oil_feed_fluid",
      "properties": {
        "flowRate": [1000.0, "kg/hr"],
        "temperature": [31.0, "C"],
        "pressure": [7.55, "bara"]
      }
    }
  ]
}

This avoids the common failure mode where every feed is rebuilt from the same default fluid. For E300-characterized oils, it also ensures each stream keeps its own composition and component property snapshot.

Multi-Area ProcessModel Export

For platform-scale models, split the plant into separate ProcessSystem objects and combine them with ProcessModel. JSON export preserves:

Feature JSON treatment
Process area names Top-level areas keys
Cross-area streams interAreaLinks plus materialized boundary streams for area-level rebuilds
Execution controls runStep, maxIterations, and tolerances
Recycle settings Flow, composition, temperature and pressure tolerances, priority, max iterations, acceleration method, Wegstein settings, downstream properties
Compressor behavior Outlet pressure, speed controls, compressor chart, surge curve, stonewall curve, anti-surge settings
Calculator equipment Calculator input and output equipment references
Pipelines Length, diameter, elevation, wall roughness, and number of increments
Heaters/coolers Outlet temperature, pressure drop, explicit outlet pressure
Heat exchangers Inlet streams, UA value, and outlet-temperature guesses

The MCP runner now applies top-level ProcessModel execution settings before running the model. Use runStep: false when the JSON should converge the same way as the original plant model.

Verification Checklist

After exporting a model that depends on E300 characterization, inspect the JSON text for these fields:

Check Expected result
"componentProperties" Present in default and named fluids
"useVolumeCorrection" Present and true for volume-corrected fluids
"volumeCorrection" or "volumeShift" Present for E300/TBP/plus components where used
"omegaA" Present when an EoS component has an OmegaA override
"binaryInteractionParameters" Present when non-zero scalar kij values are configured
"fluidRef" Present on explicit stream units with their own fluid
"interAreaLinks" Present for ProcessModel cross-area stream references
"runStep": false Present for run-to-convergence MCP execution
Recycle tolerances Present for recycle units with customized convergence settings

Then compare the rebuilt or MCP-run report against the original model:

Quantity Why it is checked
Gas export standard flow Confirms gas composition, standard volume basis, and compressor routing
Gas export mass flow Confirms total material balance
Oil export mass flow Confirms liquid routing and pumps
Oil export volume flow Confirms liquid density and volume correction
Stable oil volume flow Confirms E300-like liquid property replay after stabilization
convergenceSummary Confirms run mode, iteration count, boundary residuals, and unsolved areas

Mass rates should normally match first. If mass rates match but oil volume rates differ, inspect useVolumeCorrection, volumeCorrection, density, and componentProperties before changing process equipment settings.

MCP Execution Notes

MCP runs process JSON through ProcessRunner.run(json). The response has two separate concepts:

Response field Meaning
status: success JSON built and the simulation run completed without an exception
provenance.converged The ProcessModel convergence criteria were met
convergenceSummary Detailed iteration count, boundary errors, and unsolved process areas

For multi-area models, treat status: success as a successful execution, not as proof of final convergence. Check provenance.converged and convergenceSummary before accepting the run.

When to Use e300FilePath

Use e300FilePath only when the JSON consumer can access the same E300 file path:

{
  "fluid": {
    "model": "PR_LK",
    "temperature": 310.15,
    "pressure": 50.0,
    "e300FilePath": "C:/models/basefluid.e300"
  },
  "process": []
}

This mode is useful for local jobs and interactive debugging. It is less suitable for MCP or web APIs because the server may not have that file. For portable artifacts, export the already-loaded model and rely on componentProperties instead.

Troubleshooting

Symptom Likely cause Fix
Oil mass matches but oil volume differs Missing volume correction or component property snapshot Re-export with current toJson() and verify useVolumeCorrection plus componentProperties
All feeds rebuild with same composition Missing stream-level fluidRef Export from the live model rather than hand-copying only root fluid
MCP says success but not converged Model ran but boundary residuals or area recycle units did not meet tolerances Check convergenceSummary, recycle settings, and maxIterations
Recycle settings differ after import Old JSON did not include recycle tolerances or acceleration settings Re-export with current JSON exporter
Compressor train changes behavior Missing chart, surge, stonewall, anti-surge, or calculator data Verify compressorChart, antiSurge, and calculator references in JSON