Skip to the content.

SevereSlugAnalyser (package neqsim.process.measurementdevice.simpleflowregime) is a fast, lumped dynamic model of riser-induced (severe) slugging. It is a screening tool: it answers “does this flowline–riser operating point cycle, and how large is the riser-base pressure swing?” in milliseconds. It is not a substitute for a distributed transient simulation.

NeqSim has two complementary severe-slugging screens:

Tool Type Answers Needs
SevereSlugAnalyser Lumped dynamic simulation (this page) Cycles or not, pressure swing, regime label Geometry, superficial velocities, outlet pressure
SevereSluggingSystemDiagnostic Quasi-steady Taitel (1986) criterion Stable / unstable and pressure margin A solved TwoFluidPipe profile or an explicit descriptor

See TwoFluidPipe model for the Taitel diagnostic.

Geometry and conventions

Input Unit Meaning
internalDiameter m Same diameter for flowline and riser
leftLength m Flowline length upstream of the riser base
rightLength m Height of the vertical riser
angle degrees Downward inclination of the flowline towards the riser base; must be > 0
usl m/s Superficial liquid velocity at flowing conditions
usg m/s Superficial gas velocity at the gas reference pressure
gasReferencePressure Pa (absolute) Pressure at which usg is defined. Default 1.0e5 Pa; stream-based constructors use the stream pressure
outletPressure Pa (absolute) Pressure at the riser top
temperature °C Isothermal gas temperature
simulationTime s Simulated time
numberOfTimeSteps – Number of stored output samples

The gas mass inflow is proportional to usg × gasReferencePressure. If you pass a velocity measured at standard conditions keep the default reference pressure; if you compute it from a stream, the stream-based constructors set the reference pressure for you.

Model

Three states are integrated: the mixture velocity of the liquid slug $U_m$, the riser void fraction $\alpha_r$ and the flowline gas pressure $P$ (plus the liquid-front position $z$ in the flowline when the bend is blocked).

Oil and water are lumped into one liquid by FluidSevereSlug using in-situ volume fractions: density is the volume-weighted average and viscosity a volume-weighted linear average (no emulsion model). The gas uses the specific gas constant $R/M$ of the gas phase.

The integration is explicit with internal sub-steps of at most 1 ms, so the result does not depend on numberOfTimeSteps; that parameter only sets the resolution of the stored trend.

Outputs

Method Unit Meaning
getPredictedFlowRegime() text Regime label, see below
getMeasuredValue() / getSlugValue() – Half the peak-to-peak riser-base pressure swing divided by the mean pressure
getPressureAmplitude() bar Peak-to-peak riser-base pressure swing
getMeanPressure() bara Mean riser-base pressure
getPressureTrend(), getTimeTrend() bara, s Simulated trend

All statistics use the second half of the simulation, after the start-up transient.

Label Condition
Severe Slug slug value > 0.1 and slug hold-up > stratified hold-up
Severe Slug 2. Small pressure variations slug value > 0.05 and slug hold-up > stratified hold-up
Slug Flow slug hold-up ≤ stratified hold-up
Liquid droplets flow / Gas droplets flow / Stratified Flow otherwise, by stratified hold-up < 0.1 / > 0.9 / between
Single Phase gas or liquid missing
Regime cannot be detected … flowline angle ≤ 0

The slug value is normalised by absolute pressure, so the same pressure swing gives a smaller value at high pressure. Use getPressureAmplitude() and compare it with the riser liquid head $\rho_L g H$ when judging severity for a high-pressure system.

Usage

SystemInterface fluid = new SystemSrkEos(273.15 + 15.0, 10.0);
fluid.addComponent("methane", 0.00015, "MSm^3/day");
fluid.addComponent("n-heptane", 0.0015, "MSm^3/day");
fluid.addComponent("water", 0.00015, "MSm^3/day");
fluid.setMixingRule(2);
fluid.setMultiPhaseCheck(true);
Stream stream = new Stream("feed", fluid);

// diameter, flowline length, riser height, flowline angle [deg],
// outlet pressure [Pa], temperature [C], simulation time [s], samples
SevereSlugAnalyser analyser =
    new SevereSlugAnalyser("riser", stream, 0.05, 167.0, 7.7, 0.1, 1.0e5, 15.0, 500.0, 50000);

String regime = analyser.getPredictedFlowRegime();
double slugValue = analyser.getMeasuredValue();
double swingBar = analyser.getPressureAmplitude();

Explicit superficial velocities (for example a laboratory air–water case):

Pipe pipe = new Pipe("lab", 0.05, 167.0, 7.7, 2.0);
FluidSevereSlug airWater = new FluidSevereSlug(1000.0, 0.001, 0.029); // kg/m3, Pa s, kg/mol
SevereSlugAnalyser analyser = new SevereSlugAnalyser("lab", 1.0e5, 20.0, 500.0, 20000);
analyser.setSuperficialLiquidVelocity(0.1);
analyser.setSuperficialGasVelocity(0.5); // at 1.0e5 Pa reference pressure
String regime = analyser.getPredictedFlowRegime(airWater, pipe, analyser);

Choosing the simulation time

A severe-slugging cycle lasts roughly the time needed to fill the riser and the blocked part of the flowline with liquid, of order $(H + \alpha_L L)/U_{sl}$. The second half of the simulation must contain at least one full cycle, otherwise the pressure swing is under-reported. For low liquid rates use several thousand seconds; the model is cheap enough.

Limits

Behaviour changes (2026-11)

Earlier versions contained defects that changed results. If you compare with old numbers:

References