SevereSlugAnalyser (package neqsim.process.measurementdevice.simpleflowregime) is a fast, lumped
dynamic model of riser-induced (severe) slugging. It is a screening tool: it answers “does this
flowline–riser operating point cycle, and how large is the riser-base pressure swing?” in
milliseconds. It is not a substitute for a distributed transient simulation.
NeqSim has two complementary severe-slugging screens:
| Tool | Type | Answers | Needs |
|---|---|---|---|
SevereSlugAnalyser |
Lumped dynamic simulation (this page) | Cycles or not, pressure swing, regime label | Geometry, superficial velocities, outlet pressure |
SevereSluggingSystemDiagnostic |
Quasi-steady Taitel (1986) criterion | Stable / unstable and pressure margin | A solved TwoFluidPipe profile or an explicit descriptor |
See TwoFluidPipe model for the Taitel diagnostic.
Geometry and conventions
| Input | Unit | Meaning |
|---|---|---|
internalDiameter |
m | Same diameter for flowline and riser |
leftLength |
m | Flowline length upstream of the riser base |
rightLength |
m | Height of the vertical riser |
angle |
degrees | Downward inclination of the flowline towards the riser base; must be > 0 |
usl |
m/s | Superficial liquid velocity at flowing conditions |
usg |
m/s | Superficial gas velocity at the gas reference pressure |
gasReferencePressure |
Pa (absolute) | Pressure at which usg is defined. Default 1.0e5 Pa; stream-based constructors use the stream pressure |
outletPressure |
Pa (absolute) | Pressure at the riser top |
temperature |
°C | Isothermal gas temperature |
simulationTime |
s | Simulated time |
numberOfTimeSteps |
– | Number of stored output samples |
The gas mass inflow is proportional to usg × gasReferencePressure. If you pass a velocity
measured at standard conditions keep the default reference pressure; if you compute it from a
stream, the stream-based constructors set the reference pressure for you.
Model
Three states are integrated: the mixture velocity of the liquid slug $U_m$, the riser void fraction $\alpha_r$ and the flowline gas pressure $P$ (plus the liquid-front position $z$ in the flowline when the bend is blocked).
- Momentum of the liquid column in the riser and the blocked part of the flowline: pressure difference $P - P_{out}$ against wall friction (Blasius / laminar), riser head $\rho_m g H$, and the head recovered from liquid backed up in the downward flowline.
- Gas mass balance of the flowline gas volume $A\,\alpha_L\,(L+z)$ as an isothermal ideal gas. $\alpha_L$ is the gas fraction of the stratified flowline, from a stratified hold-up balance.
- Liquid front: when the bend is blocked, the liquid only has to fill the gas fraction of the stratified flowline, so the front moves at $(U_m - U_{sl})/\alpha_L$.
- Riser void fraction from gas and liquid balances with a drift-flux slip ($C_0 = 1.2$ turbulent, 2.0 laminar; drift $0.35\sqrt{gD}$).
Oil and water are lumped into one liquid by FluidSevereSlug using in-situ volume fractions:
density is the volume-weighted average and viscosity a volume-weighted linear average (no
emulsion model). The gas uses the specific gas constant $R/M$ of the gas phase.
The integration is explicit with internal sub-steps of at most 1 ms, so the result does not depend
on numberOfTimeSteps; that parameter only sets the resolution of the stored trend.
Outputs
| Method | Unit | Meaning |
|---|---|---|
getPredictedFlowRegime() |
text | Regime label, see below |
getMeasuredValue() / getSlugValue() |
– | Half the peak-to-peak riser-base pressure swing divided by the mean pressure |
getPressureAmplitude() |
bar | Peak-to-peak riser-base pressure swing |
getMeanPressure() |
bara | Mean riser-base pressure |
getPressureTrend(), getTimeTrend() |
bara, s | Simulated trend |
All statistics use the second half of the simulation, after the start-up transient.
| Label | Condition |
|---|---|
Severe Slug |
slug value > 0.1 and slug hold-up > stratified hold-up |
Severe Slug 2. Small pressure variations |
slug value > 0.05 and slug hold-up > stratified hold-up |
Slug Flow |
slug hold-up ≤ stratified hold-up |
Liquid droplets flow / Gas droplets flow / Stratified Flow |
otherwise, by stratified hold-up < 0.1 / > 0.9 / between |
Single Phase |
gas or liquid missing |
Regime cannot be detected … |
flowline angle ≤ 0 |
The slug value is normalised by absolute pressure, so the same pressure swing gives a smaller
value at high pressure. Use getPressureAmplitude() and compare it with the riser liquid head
$\rho_L g H$ when judging severity for a high-pressure system.
Usage
SystemInterface fluid = new SystemSrkEos(273.15 + 15.0, 10.0);
fluid.addComponent("methane", 0.00015, "MSm^3/day");
fluid.addComponent("n-heptane", 0.0015, "MSm^3/day");
fluid.addComponent("water", 0.00015, "MSm^3/day");
fluid.setMixingRule(2);
fluid.setMultiPhaseCheck(true);
Stream stream = new Stream("feed", fluid);
// diameter, flowline length, riser height, flowline angle [deg],
// outlet pressure [Pa], temperature [C], simulation time [s], samples
SevereSlugAnalyser analyser =
new SevereSlugAnalyser("riser", stream, 0.05, 167.0, 7.7, 0.1, 1.0e5, 15.0, 500.0, 50000);
String regime = analyser.getPredictedFlowRegime();
double slugValue = analyser.getMeasuredValue();
double swingBar = analyser.getPressureAmplitude();
Explicit superficial velocities (for example a laboratory air–water case):
Pipe pipe = new Pipe("lab", 0.05, 167.0, 7.7, 2.0);
FluidSevereSlug airWater = new FluidSevereSlug(1000.0, 0.001, 0.029); // kg/m3, Pa s, kg/mol
SevereSlugAnalyser analyser = new SevereSlugAnalyser("lab", 1.0e5, 20.0, 500.0, 20000);
analyser.setSuperficialLiquidVelocity(0.1);
analyser.setSuperficialGasVelocity(0.5); // at 1.0e5 Pa reference pressure
String regime = analyser.getPredictedFlowRegime(airWater, pipe, analyser);
Choosing the simulation time
A severe-slugging cycle lasts roughly the time needed to fill the riser and the blocked part of the flowline with liquid, of order $(H + \alpha_L L)/U_{sl}$. The second half of the simulation must contain at least one full cycle, otherwise the pressure swing is under-reported. For low liquid rates use several thousand seconds; the model is cheap enough.
Limits
- One diameter, a straight downward flowline and a vertical riser. No flexible-riser shapes,
no topside choke dynamics (
valveConstantis zero by default). - Isothermal ideal gas, incompressible liquid, no mass transfer between the phases.
- Oil and water are one lumped liquid; no oil–water slip, emulsion viscosity or water accumulation.
- Regime labels and thresholds are heuristics and have not been tuned against a public data set. Treat the result as a screen and confirm borderline cases with a distributed transient model.
Behaviour changes (2026-11)
Earlier versions contained defects that changed results. If you compare with old numbers:
- Stream-based constructors ignored
outletPressure,temperature,simulationTimeandnumberOfTimeStepsand always simulated 20 s at 1 bara outlet pressure with a fixed 1 ms step. - The gas inflow always used 1.0e5 Pa as reference pressure, also when
usgcame from a stream at another pressure. - The lumped liquid density used mass fractions of the total stream (including gas), which under-predicted density; the specific gas constant was wrong by many orders of magnitude for fluids built from a stream.
- The liquid front in the flowline moved at the superficial velocity instead of $(U_m - U_{sl})/\alpha_L$.
- The slug drift velocity used $\sqrt{gD}$ instead of the Bendiksen coefficients.
- The slug value was
max/mean − 1, which under-reported long build-up / short blow-out cycles. It is now half the relative peak-to-peak swing (identical for a symmetric oscillation). - Phases were addressed by index, which failed when the gas was not phase 0.
References
- Taitel, Y. (1986). Stability of Severe Slugging. Int. J. Multiphase Flow 12(2), 203–217.
- Bendiksen, K.H. (1984). An experimental investigation of the motion of long bubbles in inclined tubes. Int. J. Multiphase Flow 10(4), 467–483.
- Schmidt, Z., Brill, J.P., Beggs, H.D. (1980). Experimental Study of Severe Slugging in a Two-Phase-Flow Pipeline–Riser Pipe System. SPE Journal 20(5), 407–414.