This page is the qualification boundary for TwoFluidPipe. It separates available code from numerical verification and public experimental qualification. A completed calculation, finite profile, small pressure change, or stationary pressure trace is not by itself evidence that the model converged or represents the requested physics.

Evidence labels

Label Meaning
Implemented The public configuration and runtime path exist. This says nothing about convergence or accuracy.
Numerically verified An executable test checks relevant conservation, convergence, boundedness, sensitivity, or refinement contracts.
Experimentally qualified A reproducible public measured-data comparison passes its declared error gates, with source provenance and uncertainty or acceptance definitions.
Not qualified A required numerical or experimental gate fails, is unavailable, or has not been run. The result must not be promoted by loosening the gate.
Unsupported The configuration is rejected because the governing boundary or state information is missing.

Current evidence matrix

The transaction/execution update at 1f65f683 passed 422 focused tests in 62 classes, including four separately selected slow coupled/reference tests. Fifteen riser and one coarse-gas five-second gates failed separately at that revision. The later outlet-consistency repair clears the coarse-gas gate and promotes it to ordinary CI; the fifteen unsplit riser gates remain unsuccessful, with a countercurrent annular/slug force discontinuity isolated in a failing replay. The subsequent coupled-predictor repair restores all five coupled-pressure progress regressions without rejected substeps. These counts distinguish the verified runtime contracts below from the incomplete flow qualification.

The matrix was refreshed on current master 1f6d1c12827d844e69cdf6f38d65d1b5276f831a before the directional-ledger work. All fifteen unchanged opt-in five-second riser cases still fail. Historical midpoint 16/0.1, 16/0.05 and 24/0.05 stop at 0.82734375, 0.775 and 0.63125 s; historical backward-Euler/interpolated-pressure cases stop at 1.3015625, 1.840625 and 0.95 s (the last reaches the iteration limit; the rest fail line search). Explicit-face-terrain cases stop at 1.050390625, 1.153515625 and 0.572265625 s. The six film-constrained historical/face cases stop at 1.3015625, 1.275, 0.925, 1.250390625, 1.817578125 and 1.684375 s, all by line-search failure. No 180 s or 600 s run is justified until this unchanged five-second matrix passes.

Capability and configuration Implemented Numerically verified Experimentally qualified Evidence and use boundary
Positive-flow steady gas/liquid pressure, holdup, thermal and terrain profiles Yes Yes No general claim Require the complete steady convergence report to be converged, every residual below its recorded tolerance (including total phase mass flux below getMassFluxTolerance()), and no pressure-floor or wall-clock termination. Repeat mesh sensitivity for the actual geometry.
Steady gas/oil/water on the compact 3 km, 10-degree uphill fixture Yes Yes No The 30/60-cell results differ by 0.538% in arrival pressure and 0.983% in mean liquid holdup. All three phases remain present and the final thermodynamic/holdup reconciliation is inside the unchanged 1e-4 tolerance. The unavailable historical 73.8 km case is not covered.
Liquid-rich unchanged-boundary transient with shared slug force balance, interfacial pressure, and coupled pressure/momentum Opt-in Yes Not applicable Over 1,800 s, inventory drift is 1.323% at 40 cells and 1.358% at 80 cells, below the declared 2% fixture gate, with total-mass closure. This does not qualify slug loads or another operating envelope.
Line packing against a closed outlet on the coupled pressure/momentum route without phase transfer (setFrozenCompositionDensityUpdate, default on) Yes Yes No TwoFluidPipeFrozenCompositionDensityTest: a closed 400 m gas/volatile-oil line fed 50 kg/s for 20 s from 170 bara ends at 233.6 bara against 229.1 bara for frozen-composition compression of the final gas and oil inventory; the previous equilibrium reset ends at 334.0 bara. Phases exchange no mass, so gas dissolving into oil during a slow pack-up is not represented; use mass transfer or component transport for that. A 15.6 km tie-back pack-up to 232 barg completes 3000 s with 23 riser-top pressure steps above 1 bar, 13 bar at most (131 bar before), because near-dry riser-top cells still change regime when their gas velocity changes sign. No measured pack-up data are compared.
Default liquid-rich unchanged-boundary transient Yes No No The recorded 1,800 s inventory drift is 5.757%, above the unchanged 5% gate. Do not infer default-mode qualification from the opt-in shared-force result.
Mohmmed et al. public horizontal air/water slug kinematics Harness and data implemented Conservation only Failed At 40 cells and 0.05 s outer steps, 3/9 comparisons pass, MARE is 1.0402, and maximum absolute relative error is 3.2147. The 40/80-cell and 0.05/0.025 s sweep is non-monotone; steady starts are unconverged and pressure-floor limited and transients clamp outlet backflow. The fixed 20% speed and 30% length/frequency gates remain unchanged.
Conservative severe-slugging characterization against the public Tengesdal envelope Opt-in Five-second coupled progress restored Failed The earlier 600 s run gave 65.163 kPa, below the 68.6 kPa lower gate, without required repeated settled cycles. Centered pressure traction restores the five-second shared-closure and subcell-force regressions while retaining the valid bubble-domain guard. Short numerical progress does not qualify the experimental amplitude, period or sustained-cycle gates.
Conservative total-energy thermodynamic recovery Experimental opt-in Ideal-gas blowdown/filling, closed heating, fixed three-phase composition transport and closed hydrocarbon condensation/reheat refinement No setUseConservativeEnergyRecovery(true) requires coupled Euler and named components, with a single energy owner and complete-interval rollback. Check getLastConservativeEnergyReport() first-law, occupied-volume and EOS-state residuals. TwoFluidPipeConservativeTransitionTest retains positive relaxation tails; flowing phase appearance/disappearance, arbitrary blowdown/restart and asset evaporation-time qualification remain open under #4595/#4597.
Conservative stiff wall/interface friction through first oil appearance Automatic within conservative-energy Euler Native-force/matrix consistency, analytical source limits and bounded rich-gas regressions No ConservativeWallFrictionTest and ConservativeInterfacialDragTest check the frozen-resistance source, passive wall work, trace conditioning, oil/water slip, momentum and unchanged total energy. TwoFluidRichGasDragQualificationTest crosses the former 31.75–32.375 s rejections through 33 s on 12/24 cells. This is first-order numerical source qualification; complete blowdown, terrain pooling, restart and predictive evaporation rates remain unqualified.
Conservative passive-friction ownership in unsplit preparation Automatic without transient pressure interpolation Source passivity, exact phase-mass invariance, transactional restoration, accepted impulse/rate ledgers, six ordinary handoffs and three five-second midpoint lanes No The converged transport candidate receives the existing frozen-resistance wall, gas/liquid and oil/water source exactly once. PreparedStep and PreparedInterval expose accepted phase momentum impulses per pipe length; rejected trials publish nothing. The unchanged backward-Euler/pressure-interpolated lanes remain failed at 1.4000/1.8125/0.9750 s and keep their prior friction owner because combining the operators regresses the unresolved trace-phase/donor event. The complete six-lane gate, 180/600 s qualification, restart and pigging remain open.
Flash-driven phase appearance/disappearance with phase and energy ledgers Yes Yes No Check gas/oil/water and total mass, transfer closure, temperature sensitivity, and latent-inclusive energy balance. Record EOS, mixing rule, composition, pressure, temperature, relaxation time, mesh, and time step.
Named-component advection for supported positive-flow boundaries Yes Yes No Require every named-component ledger, bounded normalized phase fractions, phase/component synchronization, and component-sum closure. Every representable nonzero signed face transfer carries composition; mass tolerances scale audits rather than erase a transfer.
Same-step source/incoming-funded advection of a newly appearing phase Yes Reduced transport and bounded pipeline regression No TwoFluidPhaseAppearanceAdvectionTest checks shared donor budgets, old upwind composition, signed trace transfers, conservative relay through initially empty cells, outlet accounting and transactional rejection. TwoFluidPhaseAppearancePipelineTest advances a synthetic SRK 5 km/12-cell rich-gas depressurization through first oil appearance at 17.75 s with 0.25 s steps and 30 s transfer relaxation, preserving phase/component/source closure with exactly zero initial liquid. The public level-outlet conservative replay advances from 35.25 s to 94.25 s after the empty-phase repair, then rejects a material outlet-cell n-heptane deficit. Full blowdown thermal recovery, pooling and restart remain unqualified.
Positive trace-phase component inventory at synchronization Yes Yes No TwoFluidComponentTraceInventoryTest checks repeated closed substeps at 1e-15 to 2e-10 kg and nonzero condensation sources at 1e-15 to 1e-12 kg/(m s). Every positive hydrodynamic phase requires named components; a zero-component candidate rejects transactionally even below the audit tolerance. The synchronization allowance must not erase transported components.
Coupled closed-face momentum response Yes Short-time analytical limit No TwoFluidClosedBoundaryMomentumTest checks Euler and RK4: a finite pressure impulse over 1e-8 s retains adjacent physical-cell inertia, while both integrated external mass fluxes are exactly zero and total mass closes. Legacy uncoupled boundary handling is unchanged.
Component-resolved downstream outlet and rejected component-substep isolation Yes Yes No The published component flows equal accepted outlet transfers divided by interval duration, including after TP reflashing. Unequal gas/oil/water transport, delayed composition fronts, reordered names, zero flow and failure isolation are tested. General unsplit component advection remains open.
Complete legacy transient transaction Opt-in Bounded regression coverage No Failed intervals preserve accepted hydro/component/thermal/slug state, reports, histories and clocks. Connected streams, upstream storage, thermal calculators and layers retain identity. Other owned submodels are new snapshots after acceptance. Concrete SRK/PR/SRK-CPA/SRK-CPAs and ideal-gas phases are supported; unaudited EOSs and pipe subclasses reject.
Legacy IMEX compression/expansion response Yes Linear-acoustic restoring-force and mass checks No The scalar pressure correction opposes compression/expansion instead of amplifying it. Phase mass remains explicit and the scalar total-mass residual does not establish multiphase volume closure or unrestricted acoustic timesteps.
Countercurrent liquid-wall work and absent-phase mechanical terms Yes Force/power, conservative gravity, trace and boundary regressions No Unresolved wall force is partitioned by phase inertia, gravity uses each conservative phase mass, and exactly absent phases cannot create boundary NaNs or false backflow warnings. These checks do not qualify resolved phase wetting or arbitrary terrain well balancing.
Coupled fluid/multi-layer thermal exchange Yes Passive bounds, analytical refinement and energy ledgers No Backward Euler advances fluid and radial capacities together with consistent endpoint ambient flux. Adiabatic energy-enabled cases retain temperature advection, and both thermal routes retain elevation work. Remaining explicit thermal sources still require time/mesh sensitivity.
Frozen-phase unsplit execution through runTransient Opt-in Five-second 16/24-cell and 0.1/0.05 s matrix plus 180/600 s 16-cell duration gates No Always stages complete intervals and verifies accepted phase ledgers. Original SRK/PR density anchors and uniform frozen phase compositions persist across calls. Reverse outlet phase transfer requires an explicit matching boundary donor, remains signed in conservation and is excluded from the forward stream. A duration-weighted local nonlinear budget protects the unchanged 1e-8 cumulative gate without mutating solver settings; compensated sums preserve long signed ledgers. Spatially nonuniform/changing composition, energy/phase transfer and nonconservative tracking modes remain unsupported.
Transactional moving conservative slug/film geometry in unsplit execution Experimental opt-in Closed seeded three-phase rollback, exact phase conservation, four/eight-cell and 0.01/0.005 s refinement No Every attempt uses the last accepted marker reconstruction; only accepted, independently verified substeps advance the cloned tracker, and complete-interval publication replaces the live tracker atomically. Adjacent time endpoints agree within 0.02 m and four/eight-cell endpoints within 0.04 m over 0.01 s. This is short seeded geometry/face-flux evidence. Conservative subcell slug forces, changing composition, energy/phase transfer, full Tengesdal tracking-on publication, experimental cycles, restart and pigging remain open.
Five-second gas execution and uniform three-phase fixed point Opt-in Selected configurations No Four-cell gas runs at 0.1 s and eight/sixteen-cell runs at 0.05 s pass consecutive accepted calls with unchanged nonlinear/interval tolerances of 1e-10/1e-8. Consistent outlet phase fractions repair the single-phase Jacobian kink; the coarse case now runs in ordinary CI. These are continuation/conservation checks, not spatial-accuracy qualification. A separate closed uniform three-phase fixed point passes.
Inclined annular film eligibility, transition blending and trace-phase Jacobian Opt-in criteria; derivative correction enabled Local branch and analytic derivatives No The captured 0.594-liquid-holdup conflict converges with the film constraint. A separate opt-in annular/slug force blend removes the gas-lift point switch and advances the historical backward-Euler 16-cell gates from 0.663/0.688 s to 1.451/1.671 s; the 24-cell gate reaches 0.95 s. All still fail before five seconds. Phase-relative probes retain trace drag/volume derivatives. Neither local criterion implements full film/droplet/reversal physics.
Directional phase-face complementarity Experimental opt-in augmented solve Unit, coupled adapter, exact-absent donor, conservation and 53-color layout coverage; six unchanged 0.1 s Tengesdal lanes pass No The nonlinear vector adds signed-direction mass, advective momentum and donor multiplier variables per internal phase face. Present donors use normalized conservative advection; exactly absent donors use exact donor-presence/zero-momentum rows. Solved transport replaces the free internal flux conservatively and prepared-step verification reuses it. No inventory is clipped and no donor smearing is used. The unchanged 15-case five-second matrix still fails at 0.1251953125–0.831640625 s, so phase-transition, restart and pigging qualification remain open.
Bidirectional Rusanov internal phase transport Experimental opt-in Analytical two-stream decomposition, exact net recovery, dry/trace/SRK local controls, Runge–Kutta staging, pressure-work ownership, transactional named-component conservation and fail-closed configuration tests No setRusanovInternalFluxEnabled(true) requires independent gas/oil/water faces. Forward and reverse donor streams remain separate through component transport while their difference is the hydrodynamic net. AUSM remains default. Combined-liquid splitting, pressure interpolation, reconstructed slug faces and one-direction unsplit complementarity reject. This is numerical face-transport qualification, not dry/wet-front, restart, evaporation, slugging or pigging qualification.
Historical-grid unsplit Tengesdal publication matrix Harness implemented Passed for 16/0.1, 16/0.05 and 24/0.05 s five-second lanes; 16/0.1 s also passes 180/600 s No Backward Euler, pressure interpolation, transition blending and signed donor transport publish complete intervals atomically at the unchanged cumulative 1e-8 gate. This supersedes the older failed historical-grid prefixes for this option set, but not the distinct corrected-face/film-constrained failures. It is numerical duration/conservation evidence only; experimental amplitude, period and repeated-cycle qualification, restart and pigging remain open.
Explicit finite-volume face terrain Opt-in Yes No N+1 elevations, actual cell arc lengths and midpoint pressure with external-face offsets. Signed gravity/energy and constant-density hydrostatics are checked under nonuniform refinement. This is not general transient well-balancing.
Terrain low-point pool reporting Explicit read-only capture Exact multi-low basin partition/inventory/source aggregation and horizontal no-pool control No TwoFluidPipeReport.captureLowPointPools(...) partitions strict internal minima at intervening ridges and exports per-basin oil mass/volume, total liquid volume, low-point/maximum static depth, gas/oil speeds and accepted hydrocarbon-transfer area/rate/heat diagnostics. It does not impose pool positions and has no ordinary-solve cost when unused. This is auditable instrumentation, not evidence of gravity retention, spatial convergence, physical interface area or predictive depletion time.
Conservative slug/film + named components + phase transfer + thermal balance Yes Yes No A closed four-cell wet-gas cooling case over 0.05 s closes all ledgers on 0.05/0.025/0.0125 s outer partitions. Adjacent-grid water/heat sensitivity is below 4%; marker-displacement sensitivity decreases from 3.14% to 1.99%. Marker length/age are partition-invariant, and transactions reproduce the same-grid result. See the model guide for numerical values. This is coupled-ledger evidence, not spontaneous slug initiation.
Restart pressure-trace metrics Explicit read-only analysis Analytical monotonic and four-leg ringing traces plus invalid-sample controls No TwoFluidPipeReport.analyzePressureTrace(...) reports extrema/times, peak-to-peak pressure, maximum adjacent-sample rate, total/excess variation, ringing ratio and direction reversals above an explicit caller-supplied Pa gate. It performs no filtering, fitting or interpolation. The full-cycle screen now preserves the physical level-outlet extent under refinement; its executed hydrocarbon-pool-transfer receipt supersedes the earlier comparison of different terrains. Pressure traces still require mesh/time and independent surge validation.
Pressure-driven inlet reservoir and restart ramp Experimental conservative transient API Analytical acoustic inflow/outflow, flashed phase/component/enthalpy donor, closed-face pressure continuity, full 780 s mass/component/energy cycle on 12/24 cells and 0.5/0.25 s intervals No CONSTANT_PRESSURE resolves signed phase speed from two-sided acoustic impedance and uses the external donor only for inflow. setInletBoundaryFluid(...) overrides the connected reservoir; getInletFacePressure(unit) provides the accepted event-start traction. Inventory and pressure-amplitude/rate refinement gates pass for the declared screen. The 0.25 s trace retains one sub-2 kPa opening reversal, and no independent public restart/surge data are qualified. This is not valve/orifice flow, gelled-oil restart, repeated-cycle or moving-pig evidence.
Flowing stratified gas/oil transfer area Experimental opt-in Independent circular-segment and trace limits; uniform/nonuniform source partition, unseeded appearance, heat-limit and serialization controls No HydrocarbonPoolTransfer.forStratifiedFlow(...) extends the local holdup chord along cell arclength and preserves total area and paired species rates under subdivision of a uniform state. It retains the component/donor/heat/total-energy owners. This is a distinct area assumption from the per-cell stationary forHydrostaticPool(...) reconstruction. Historical static-cycle failures remain evidence; neither local partition invariance nor a flowing-cycle inventory pass validates stationary-pool dynamics, measured kinetics, restart surge or moving-pig conservation.
Non-equilibrium post-pigging MEG/water transfer Experimental opt-in Short-time component/coupling tests No Separate initial aqueous inventory, independent signed species fluxes, Euler/isothermal restriction. Seeded low-point motion is tested; long-horizon drying, pool formation and experimental accuracy remain unqualified. See film transfer.
Reduced-order ideal-gas pig coupling (separate from TwoFluidPipe) Experimental Java/JPype API Closed mass/combined-energy ledgers, bidirectional choked/subcritical bypass, breakaway, reversal-safe first-position/receiver events, serialization, 20/10/5 ms refinement and nearby bypass-diameter trend on public 62 m/52 mm geometry No Two well-mixed calorically perfect gas chambers using PigMotion and IdealGasReleaseModel. The position-event API is checked against analytical acceleration/reversal cases and the public Lima 5.90 m/13.6 s sensor timing, but that source provides no redistributable pressure-force trace. Public geometry is provenance only; pressures, friction, pig mass, bypass and dead volumes are synthetic. No distributed waves/friction/heat, liquid sweep, receiver liquid capacity, residual film, physical restart, severe slugging, experimental trajectory validation or field parity. See pig motion.
Dry gas/oil component-target relaxation in conservative Euler Experimental approximation Frozen-inventory exponential/refinement and donor-momentum controls; complete source-only oil disappearance into single-gas targets at 50 bara/480–520 K; original 12/24-cell pressure-ramp regression No Each source uses its conserved component inventory difference from the local equilibrium target. Counter-transfers carry actual donor momentum with one total-energy owner. The hot disappearance test qualifies the frozen algebraic endpoint, not seabed heating or evaporation time. Aqueous grids retain the previous closure. The historical flat-outlet 12-cell/0.125 s case still rejects an inadmissible liquid velocity at 35.625 s; full pooling, inlet refill, heat/area/transport-rate and experimental qualification remain open.
Reverse outlet inflow with named-component transport and no external composition Unsupported Fail-closed No Configuration is rejected in either setter order. The last interior composition is not a physical external boundary condition.
Signed prescribed inlet flow Yes Countercurrent phase mass/momentum/energy donor tests across unequal inlet/cell areas and both state setters; trial-pressure/source balance with separate phase pressure enabled/disabled; exact −0.17 kg/s three-phase rate; signed named-component ledger; phase-resolved total/pressure-only boundary momentum diagnostics No Positive phases use the external inlet state and its supplied face area. Negative phases use the first physical cell and its area, so outflow cannot inherit an unrelated feed mixture. Pressure traction and its matching source retain interior geometry and phase availability. The diagnostics separate donor advection from pressure traction but are not a complete external-force momentum residual. This is a boundary conservation contract, not a reservoir inflow model or full blowdown/refill qualification.
Local gas/oil film simultaneous mass/heat solve Separate default-off boundary option; not integrated into transient source Binary/six-component zero-driving-force and nearby equation/refinement controls No setCoupledMassHeatTransferEnabled(true) uses the existing film/EOS equations with full residual acceptance. Requires positive finite transport and strictly positive nonreactive hydrocarbon interface composition. Stationary liquid with zero correlation coefficient rejects; no unit-conductance fallback. See CoupledGasOilFilmTest and the film-method limits. This does not qualify stagnant-pool diffusion, interfacial area/heat supply, phase disappearance or predictive depletion time under #4675.
Reverse pressure-outlet inflow with an explicit external thermodynamic donor Experimental opt-in Signed component/mass/enthalpy unit tests and synthetic rich-gas pressure-ramp regression No setOutletBoundaryFluid(...) owns reversed phase composition, density and enthalpy; setAllowOutletPhaseBackflow(true) enables signed transport. The net conservation ledger stays signed while downstream publication contains only positive outbound material. The 40 s depressurization plus pressure reversal closes mass, named-component and full-energy reports. This is boundary-contract evidence, not complete blowdown, pooling, refill or predictive transfer-rate qualification.
Gas-only constant-pressure outlet retaining oil and water Experimental opt-in Phase-flux/energy, coupled pressure projection and 33 s rich-gas phase-appearance ramp at 0.25/0.125 s No setGasOnlyOutletTakeoff(true) leaves gas transmissive while oil/water external mass, component and advected-energy transfers are exactly zero. Retained phases keep pressure traction and internal drainage. The outlet pressure projection changes only gas inventory and rejects negative gas transfer unless setOutletBoundaryFluid(...) supplies the external composition and enthalpy. Halving the rich-gas interval changes cumulative gas discharge from 75,177.35 to 74,994.75 kg (0.244%, below the predeclared 1% boundary tolerance), while peak trace-oil inventory falls from 0.892 to 0.684 kg (23.3%). The boundary conservation result is qualified; the near-onset liquid peak is not mesh/time-converged and is not a pool prediction. This does not model valve area, separator carryover, pool geometry or evaporation rate, and does not by itself qualify the complete blowdown/refill cycle.
Multi-stage conservative slug + component + phase-transfer coupling Unsupported Fail-closed No Phase appearance inside an intermediate stage needs stage-local component inventories. The coupled four-way path is currently restricted to single-stage Euler.

The Mohmmed source provenance, exact spreadsheet cells, point selection, missing-data policy, and error definitions are maintained in TwoFluidPipe Reporting and Validation. Those fixed engineering gates are not claimed as measurement confidence intervals; the paper does not publish pointwise uncertainty intervals for the selected observations.

Supported-use envelope

Use TwoFluidPipe only when the case fits a row above and its runtime evidence is retained:

  1. Run steady initialization and inspect the complete immutable convergence report. A stationary pressure profile is insufficient if liquid split, holdup, thermodynamics, or total pressure drop remains outside tolerance, or if total phase mass flux does not close against the inlet.
  2. For transient work, require requested elapsed time, phase and total mass balances, positivity, and all sticky pressure/momentum, pressure-limiter, rejected-substep, outlet-backflow, component, and energy diagnostics applicable to the selected configuration.
  3. Repeat mesh and time-step sensitivity at the actual length, diameter, inclination, composition, phase split, thermal boundary, rates, and event duration. Evidence from one fixture does not define a universal operating envelope.
  4. Treat seeded slug markers as transport/coupling probes. They do not demonstrate spontaneous slug initiation, sustained cycles, arrival statistics, or load distributions.
  5. Use PipeBeggsAndBrills for a correlation-based steady or quasi-steady screen, not for conservative distributed line-pack dynamics. Use a separately qualified transient model or a controlled experimental study when the requested TwoFluidPipe row is failed or unsupported.

High-throughput steady mass conservation (#3686)

TwoFluidPipeSteadyMassFluxTest reproduces the 3,100 m well with a 0.23 m diameter, 2,380 m rise, 20 sections, 205 bara and 90 degrees Celsius inlet, and the issue’s synthetic SRK fluid and stock-tank rates. The original 166.113217788 kg/s case lost 3.473846596 kg/s at the outlet section because gas velocity was capped at 100 m/s. At 5% higher flow the deficit was 7.007383459 kg/s; the 5% lower-flow case did not reach the cap.

The regression checks all three rates against phase-summed section mass flux with relative tolerance 1e-10 and absolute tolerance 1e-12 kg/s. It also requires the original hydraulic and thermodynamic residuals to pass. Separate gas, oil and water fixtures exercise the former steady gas/liquid caps, and injected 2% and nonfinite reporting errors must prevent convergence even when the hydraulic residuals have settled. The existing 30/60-cell three-phase fixture remains the free-water and mesh-refinement check. This is conservation and numerical-convergence evidence, not experimental or critical-flow qualification.

Executable steady and transient example

The executable TwoFluidPipeEvidenceExampleTest in src/test/java/neqsim/process/equipment/pipeline runs a 5 km, 0.30 m liquid-rich gas-condensate line at 50 kg/s, 60 bara and 50 degrees Celsius. It enables the opt-in shared slug force balance, interfacial pressure, and coupled pressure/momentum before steady initialization. The same object then advances ten one-second outer steps with unchanged boundaries.

The example fails unless:

Execute it from the repository root:

./mvnw -q -Dtest=TwoFluidPipeEvidenceExampleTest test

The exact Stage 5 execution values and source/head commit are recorded in the Stage 5 pull request and the issue #3298 series ledger. These values are reproducibility evidence for the example, not experimental qualification.

The prepared local execution on master 5bb230e1c2e2227074ce4d20ec19d6be91b53ec7 produced:

Quantity Result
Steady termination / iterations / tolerance CONVERGED / 16 / 1e-4
Steady outlet pressure 57.62005697 bara
Initial mean liquid holdup 0.269435835
Initial total inventory 72,424.765816 kg
Accepted transient duration 10.0 s
Maximum total-mass residual 1.92344e-11 kg
Maximum relative total-mass residual 2.65574e-16
Inventory drift 0.00977583%
Outlet-pressure drift 0.0%
Final mean liquid holdup 0.269473910

The Stage 5 pull request and issue ledger bind these values to the final evidence-only head.

Decision record

The five-stage evidence chain is recorded in issue #3298:

Open or draft work is not a released capability. Confirm the target release contains the referenced implementation before using its row.

Static subcell geometry diagnostic

GeometryCalculator.calculateHydrostaticCell and the read-only section accessor are numerically verified static geometry references. HydrostaticCellGeometryTest checks independent volume/area quadrature, exact empty/full cells, horizontal and signed-slope limits, partition consistency, serialization and unchanged state. A long-cell 1e-30 inclined trace verifies that leading-edge depth, volume and interface area remain positive without subtractive cancellation; the pre-existing 3,060 public reference rows remain unchanged. They are not a flowing-interface closure, stable-gravity-pool validation or a physical hydrocarbon evaporation-rate model. The existing cell-average closure geometry and transient solver remain the numerical owners. See the reporting contract.

Closed-wall mechanical pressure compatibility

The explicitly impermeable external face reconstructs its pressure from the adjacent conservative mixture inertia and half-cell gravity head. Mass and enthalpy transport remain zero. Horizontal closed-wall pressure is unchanged; nonphysical reconstructed pressure fails explicitly without a numerical floor. ClosedWallPressureCompatibilityTest covers affine pure-phase hydrostatics, horizontal acoustic pressure response and closed-flux limits. These are numerical boundary controls, not qualification of a static two-phase pool or physical hydrocarbon transfer rates.

The closed-wall reproduction record includes exact source provenance, analytical acceptance, all 12–192-cell operator data, and measured RHS cost with shared-runner limitations.

Interior hydrostatic pressure and signed work

Every internal face now reconstructs a common mechanical pressure from the two adjacent conservative mixture inertias and signed half-cell gravity heads. The same additive correction is applied to phase momentum traction, phase-pressure diagnostics and total-energy pressure work. Energy uses the signed mass donor, so the correction is exactly Q * deltaP for either flow direction. A horizontal face retains the established AUSM pressure flux exactly, and rejected transactional evaluations restore the accepted correction ledger.

HydrostaticPressureReconstructionTest passes 90 analytical stationary controls: flat, affine and public curved terrain; constant, smooth and alternating cell density; 12/24/48/96/192 cells; and pure gas or oil. The unchanged maximum acceleration gate is 1e-10 m/s2; every local mass and energy rate is exactly zero. A separate 45-case pure-water extension passes the same terrain, density, mesh and conservation gates without changing that predeclared basis. Signed -2/+2 m/s controls verify pressure work, horizontal correction is exactly zero, and rollback is exact. This is numerical well-balancing of a common mixture pressure, not validation of a stationary two-density pool, a moving interface, severe slugging, restart, phase-transfer rates, pigging or commercial parity. See the public analytical record.

MultiphaseHydrostaticForceQualificationTest adds 720 unequal-density controls and 48 signed gas/oil/water work controls. At initially zero velocity, a common mixture-hydrostatic pressure gives phase acceleration (rhoMix / rhoPhase - 1) * g * sin(theta) while the summed mixture force is zero. The fixed gates are 1e-10 m/s2 phase-acceleration error and 1e-8 N/m mixture-force residual; absent-phase mass and momentum rates and stationary energy rates are exactly zero. The work controls retain the individual donor under countercurrent flow. These are instantaneous force/flux identities, with refinement through 192 cells; no elapsed pool-retention interval, pool level, or depletion time is inferred. The public record retains every case, inspected plots, and RHS-only timing data.

Optional Rusanov phase-flux contract

RusanovConservativeFluxTest qualifies the optional Rusanov phase-flux formula against ideal-gas Euler conserved variables: total-energy pressure subtraction, kinetic energy, pressure/holdup metadata, exact absence, positive traces, signed flow, energy-reference shifts and finite arithmetic. Its mass-positivity control has an explicit Courant condition. RusanovRichGasFluxTest adds 324 SRK gas/oil local queries over 18 P/T samples, signed flow, one-sided oil absence and traces. Its internal-energy reference explicitly accounts for EOS versus physical-density volume work. These are API/numerical consistency controls, not independent EOS accuracy, translated-EOS thermodynamic qualification or elapsed pool/evaporation evidence. The executed conservative-flux record also records the two nonnegative donor streams, their exact net, pressure-only numerical energy term, stage accumulation, donor-volume pressure work and transactional component integration. The pipeline can select this operator explicitly on independent phase faces; production default remains AUSM. The current combined-liquid, reconstructed-slug and one-direction unsplit routes are deliberately incompatible. This does not qualify wet/dry fronts, pools, restart or evaporation.

Stratified hydrostatic pressure moments

The result’s derived centre-referenced phase first area moments and normal-gravity energy [J/m] are qualified by StratifiedGravityEnergyTest: closed circular-segment formula, 162 retained 80-digit references including positive phase traces down to 1e-30, equal-density/zero-gravity limits, exact absence and invalid inputs, query purity and the unchanged four-field serialized contract. No dynamic force, energy-recovery or phase-transfer call site is added. The executed energy budget distinguishes a static potential-energy change from an elapsed drainage or evaporation result. Its receipt tests reject incomplete/nonfinite timing and static-budget artifacts, validate the fixed work counts/checksum roundoff bound, and compare all three two-cell energies against independent 80-digit series references at the unchanged 5e-13 relative gate. 211 corrupted receipts and four real compiled-probe mutations reject in normal/optimized Python; no speed threshold or new dynamic qualification follows.

The opt-in geometry query GeometryCalculator.calculateStratifiedPressureMoments(depth, diameter) returns immutable signed first moments getLiquidMoment() and getGasMoment() in m3, plus getLiquidArea() and getGasArea() in m2. Depth is normal to the circular pipe cross-section. For interface depth $h$, height $y$ above the invert and chord width $w(y)=2\sqrt{y(D-y)}$, the definitions are

\[J_l=\int_0^h(h-y)w(y)\,dy,\qquad J_g=\int_h^D(h-y)w(y)\,dy.\]

Thus $J_l\geq0$, $J_g\leq0$, and $dJ_k/dh=A_k$. The hydrostatic contribution to phase pressure traction is $\rho_k g\cos(\theta)J_k$ in N; the separate interface-pressure contribution is $p_I A_k$. These are signed pressure moments about the interface, including the gas region above it, rather than moments about the pipe invert. The method integrates the smaller segment with positive 16-point quadrature and recovers its complement from the exact full-section moment. Empty phases have exactly zero moment; unrepresentable geometry fails explicitly without changing the supplied depth.

StratifiedPressureMomentsTest verifies independent angular quadrature, analytical half/full sections, trace limits, complement symmetry, area derivatives, serialization and signed finite-volume gravity/traction identities. The executed numerical record retains every case, refinement and measured opt-in query cost.

The default-off production switch TwoFluidPipe.setStratifiedHydrostaticPressureMomentsEnabled(true) couples $F_k=\rho_k g\cos(\theta)J_k$ into phase pressure traction at internal and external faces and adds the conservative work $Q_kF_k/A_k$ with the mass-flux donor density. The retained force matrix is ordered inlet/internal/outlet by gas/oil/water and is transaction-safe. The nine-test coupling matrix covers both flow directions, exact phase endpoints, a vertical control, closed-domain force telescoping, unsupported-interface and diameter rejection, rollback, public API state and bitwise default-off restoration, trace forces and countercurrent unequal-density signed donors. Its paired-fraction geometry adapter inverts the minority area without a depth floor or absolute area cutoff, including gas traces whose complementary liquid fraction rounds to one. Recovered nonnegative volume weights must satisfy the unchanged 1e-10 sum bound; only geometric fractions use weights divided by their sum, with no mutation of the conserved state. An independent 80-digit series inversion supplies 162 retained controls over six diameters and positive fractions down to 1e-30. The executed coupling record states the analytical references, units and commands.

The enabled historical rich-gas 120 s ramp fails: last accepted time is 0.25 s on both meshes; the requested 12-cell 0.5 s and 24-cell 0.375 s intervals reject the existing face-volume closure guard. Primary conservative state and elapsed time restore exactly. The default-off master ramp passes, so that result cannot qualify enabled pressure moments. The retained executable probe, accepted-interval data and rejection statuses make this dependency explicit; no closure threshold was changed to produce a transient pass.

This qualifies instantaneous phase-traction/work identities only. The one-interface circular geometry rejects simultaneous positive oil and water and diameter steps. No elapsed retained-pool, terrain drainage, cooldown, restart, severe-slugging, pigging or predictive evaporation claim follows. Capillarity, waves, entrainment and separate oil/water interfaces remain outside this API.