Skip to the content.

Differential liberation laboratory mass audit

Use pvt_dle_mass.audit_dle_mass to screen an isothermal differential liberation experiment with no material addition and gas as the sole removed material. This audit uses laboratory observations before EOS fitting. A compatible row satisfies a necessary interval overlap. Measured accuracy and holdout acceptance require separate evidence.

Basis and inputs

Supply protocol: DLE and identify the sample, experiment, source, data-use terms, final differential residual oil and meaning of the input bounds. See the synthetic JSON contract with both gas-volume routes. Use one experiment temperature in K. Stage pressures are absolute in bara and decrease with nonoverlapping pressure intervals. Every stage needs a unique ID and a source reference. Put the current stage’s released-gas molar mass and standard-state compressibility factor on the current stage.

Quantity Exact input unit
Oil formation volume factor m3/m3 residual oil
Oil density at stage conditions kg/m3
Solution gas-oil ratio Sm3/m3 residual oil
Liberated gas molar mass kg/mol
Standard gas temperature and pressure K and Pa absolute
Stage gas Z at the standard conditions 1
Gas formation volume factor at the current cell state m3 cell/Sm3 gas
Gas Z at the current cell state 1

Intervals contain the fields unit, lower and upper. Supply finite decimal strings in closed intervals. Endpoint exponents must be between −150 and 150. Use the same final differential residual-oil identity across the sequence. Separator stock-tank oil and single-flash volumes have their own definitions. Keep cooldown, nonisothermal transitions and other experiments in the source record outside this check. A missing property can be omitted or given as JSON null. A stage pressure remains required to identify ordering.

To use the cell route, supply gas_volume_factor and cell_gas_z on the withdrawal stage with a cell_gas_basis_reference that ties both measurements to the same released gas and identifies the shared standard-volume convention for the formation factor and solution GOR. Keep cell pressure absolute and use the experiment temperature. With $B_g$ in cell m³ per standard m³, the reported standard molar volume is $Z_{cell}RT_{cell}/(p_{cell}B_g)$. This calculation can use the reported volume ratio even when a standalone standard-state compressibility factor is unavailable. A partial cell route cannot supply a molar volume.

When both routes are available, the report keeps each interval. Disjoint intervals are incompatible and have no common mass-residual interval. If they overlap, the mass check uses their intersection. This is an interval consistency screen even if both routes derive from related laboratory records.

Interpretation

Per cubic metre of final differential residual oil, let $B_o$ be the stage oil volume ratio and $\rho_o$ its density. The observed oil mass lost between adjacent stages is $\Delta m_o = B_{o,i-1}\rho_{o,i-1}-B_{o,i}\rho_{o,i}$. With $\Delta R_s=R_{s,i-1}-R_{s,i}$ and released-gas molar mass $M_i$, the implied standard molar volume is $\Delta R_s M_i / \Delta m_o$. The audit reports it only when both loss and release intervals are strictly positive.

For the standard-state route the molar volume is $Z_{s,i}RT_s/p_s$, where $p_s$ is absolute and the stage gas $Z_{s,i}$ is supplied at that state. With an available molar-volume interval $V_{m,s}$, the signed mass residual is $\Delta m_o - \Delta R_s M_i / V_{m,s}$. The residual uses a gas release intersected with the nonnegative physical range. A strictly negative loss or release, or a residual interval excluding zero, is incompatible. Implied molar volumes without a declared gas basis, missing transitions, and zero or indeterminate loss or release can remain unresolved. All transitions and the original input map are retained along with a canonical input SHA-256.

Bounds are rounded outward using decimal arithmetic. Independent interval propagation permits combinations that may be impossible when measurements are correlated. Use reported uncertainties where available. If only printing precision is known, describe the result as a printing-precision screen.

Executable example

From the repository root, use the installed devtools environment:

import json
from pathlib import Path
from pvt_dle_mass import audit_dle_mass

source = Path("devtools/pvt_examples/dle_mass_audit.json")
report = audit_dle_mass(json.loads(source.read_text(encoding="utf-8")))
print([transition["status"] for transition in report["transitions"]])

The explicit synthetic example reports ["compatible"]. test_pvt_dle_mass.py runs this example and compares the computed bounds with independently enumerated exact-rational interval vertices.

Primary source screening example

The published copy of PROLAB 93.104 contains the 106 °C differential vaporization of bottle TS-29-06 from Volve 15/9-19-SR DST 1. Printed pages 8–9 identify the isothermal volumetric series and evolved-gas analyses. The final residual-oil basis refers to 15 °C and atmospheric pressure. The separately reported 15 °C cooldown is outside the isothermal stage audit.

The linked PDF was checked at SHA-256 be97500f63318bf8243918ef417810b31a424a52796d84d09a30d0507a8b211a. Under half-last-digit printing bounds, eight complete transitions had mass residual intervals containing zero when cell pressure was treated as absolute and reported gas Z and volume factors were treated as describing the same withdrawn gas and standard-volume basis as the reported GOR. The widest absolute endpoint was about 3.54 kg per m³ of final residual oil. The last isothermal stage has no reported solution GOR and remains unresolved. These are conditional source-consistency results. The source conventions and measurement uncertainty still need confirmation for EOS benchmark admission. The repository example contains original synthetic data.