Depressurization (Blowdown) per API 521

NeqSim provides neqsim.process.safety.depressurization.DepressurizationSimulator for transient vessel blowdown analysis per API STD 521 (7th ed., 2020) §5.20.

Method

The simulator integrates a vessel as a constant-volume control mass, performing a VU-flash (constant volume / internal energy) at each step:

\[\frac{dM}{dt} = -\dot{m}_{out}, \qquad \frac{dU}{dt} = \dot{Q}_{fire} - \dot{m}_{out} h_{out}\]

Fire heat input follows API 521 §4.4.13:

\[Q_{fire} = C_1 \cdot F \cdot A_{wetted}^{0.82}\]

with $C_1 = 43.2$ kW/m² (adequate drainage + prompt firefighting; otherwise $C_1 = 70.9$).

Code pattern

SystemInterface fluid = new SystemSrkEos(273.15 + 25.0, 100.0);
fluid.addComponent("methane", 0.85);
fluid.addComponent("ethane", 0.10);
fluid.addComponent("propane", 0.05);
fluid.setMixingRule("classic");
fluid.setTotalNumberOfMoles(5000.0);  // initial inventory
fluid.init(3);

DepressurizationSimulator sim = new DepressurizationSimulator(fluid);
sim.setVesselVolume(50.0);          // m³
sim.setOrificeArea(0.001);          // m² (BDV throat)
sim.setBackPressure(1.5);           // bara
sim.setHeatInput(150.0);            // kW (API 521 fire case)
sim.run(900.0, 1.0);                // 15 min, 1 s steps

double tHalf = sim.timeToPressure(50.0);  // s to 50 bara
double Tmin  = sim.minTemperatureC();     // for MDMT check
double mdotMax = sim.peakMassFlow();      // for flare network sizing

Dynamic flare header and knockout loads

DynamicBlowdownFlareStudyRunner records the component molar rates and enthalpy actually withdrawn from each vessel over each fixed interval. For a two-phase vessel under vapor withdrawal these are the discharged vapor properties. The runner adds the simultaneous rates by component name and performs an adiabatic pressure–enthalpy flash at the configured header pressure. The model assumes a common fluid-property basis and instantaneous phase separation at that pressure. Equilibrium gas feeds the tip and condensed material goes to knockout.

In flareLoad.profile, timeS marks the end of each interval. The initial zero point has zero duration. componentNames indexes the header, vapor and knockout component-rate arrays in mol/s. The corresponding enthalpy rates are in W on the source EOS reference. Totals integrate the interval means over their actual duration. Mass, molar flow, heat release and CO₂ each have their own peak and timestamp. The tip heat uses the NeqSim flare’s ISO 6976:1995 molar lower heating value at a combustion reference of 15.55 °C. Reported CO₂ includes incoming vapor CO₂ and assumes complete combustion of the other gas-phase carbon.

API 521 acceptance criteria

Criterion Limit Source
Time to ≤ 50 % design pressure ≤ 15 min API 521 §5.20.2
Minimum metal temperature ≥ MDMT (UCS-66) API 521 §5.20.3
BDV downstream pressure ≤ MAWP of flare header API 521 §5.20.5

Steady dry-gas capacity at a coincident load

Use SteadyFlareGasNetwork when several fixed-opening devices discharge a common dry gas into one header. Supply absolute pressures in bara, open nozzle areas in m², gas molar mass in kg/mol and simultaneous relief demands in kg/s. Represent each inlet and tailpipe by its inside diameter, equivalent length including fittings, and Darcy friction factor. Supply the static pressure and a rated flow/pressure point for a quadratic tip characteristic. For supplied dry-gas rating points, pass a SteadyFlareGasNetwork.TipCurve to the alternative constructor. Its paired arrays give gas mass flow in kg/s and absolute tip-inlet pressure in bara at the modeled gas and outlet conditions. Flows start at zero and strictly increase. Pressures are positive and nondecreasing. The solver interpolates linearly for both simultaneous and pre-opening states and rejects cases beyond the last point. The zero-flow pressure sets the static backpressure, and the tagged JSON retains the supplied points under tipCurve.

For a knockout drum installed between the common header pipe and tip, supply its tag and a dry-gas port-to-port rating with setKnockoutPressureDrop. The paired gas flows (kg/s) and pressure differences (bar) start at zero. The solver interpolates within this curve at the combined flow for both the operating and pre-opening states. The common pipe discharges at headerOutletBara and the drum discharges directly at tipBara. The JSON includes the installed rating under knockoutDrum. Use a curve applicable to the modeled gas and drum condition.

import java.util.Collections;
import neqsim.process.safety.depressurization.SteadyFlareGasNetwork;
import neqsim.process.safety.depressurization.SteadyFlareGasNetwork.Pipe;

// Illustrative geometry, nozzle and gas properties for a single operating point
SteadyFlareGasNetwork network = new SteadyFlareGasNetwork("header",
    new Pipe(0.14, 95.0, 0.02), "tip", 1.2, 1.2, 2.0, 300.0, 0.020, 1.0, 1.3);
network.addDevice("PSV", 8.0, new Pipe(0.25, 0.0, 0.02), 0.0002, 0.95,
    new Pipe(0.10, 120.0, 0.02), 1.6);
SteadyFlareGasNetwork.Result rating = network.rate(Collections.singletonMap("PSV", 0.4));
double availableKgS = rating.devices.get("PSV").availableKgS;
double flangeBara = rating.devices.get("PSV").outletBara;

The solver balances each nozzle against its local inlet and discharge-flange pressures and balances the combined flow at the header. For each horizontal, isothermal pipe, the pressure-squared change in Pa² is f (L/D) (mass flow / area)² ZRT/M. A negative capacity margin gives the shortfall at the specified opening. A negative outlet-pressure margin gives the exceedance of the supplied device limit. Outlet rise is measured from the common zero-flow static pressure. The solver also reports a separate steady pre-opening pressure for each device by holding that device closed with the other openings fixed. Its incremental backpressure is the difference between the local outlet pressure and that baseline. For other event sequences, supply the corresponding openings in a separate case. Represent a closed device with zero open area. An omitted limit yields a null margin in the result and its JSON export.

To rate a sampled blowdown peak, construct the network using source pressures and openings at that instant, match each device tag to its source, and call history.ratePeakGasCapacity(network). The rate comparison uses the contributions at the common sampled peak. Other instants can govern individual branches. The method assumes constant gas properties, low-Mach pipe flow and one common junction. It rejects pipe outlet Mach above 0.3 and flows outside the rated tip range. Liquid carryover, wet KO drum losses and holdup, multiple headers, line packing and transient valve lift require a separate model and qualification.

V-101 PSV-only reference at negligible losses

AdvancedV101PsvStudyTest.reliefRefinesAndReplaysWithoutMutatingCanonicalSource feeds the native PSV_RELIEF outlet rate and its timestamps into ratePeakGasCapacity at both native timesteps. The gas properties come from an SRK flash of the recorded vessel inventory at the instant of peak flow. All line lengths are zero. The imposed tip curve is flat at 1.2 bara.

Quantity 0.10 s step 0.05 s step
Native and transferred peak flow at 3.20 s, kg/s 5.49552 5.49705
Maximum protected vessel pressure, bara 42.36369 at 2.40 s 42.38967 at 2.45 s
Inlet flange pressure at peak flow, bara 42.03573 42.04747
Outlet flange, header and tip pressure, bara 1.20000 1.20000
Assumed water-equivalent nozzle capacity, kg/s 11.71485 11.71866

The synthetic native valve has a rated Cv of 80. Converting its effective Cv at peak to a water-equivalent CdA gives 1316.32 mm² in both runs. This assumed nozzle passes about 113% more gas than the observed valve. Independent nozzle area or certified capacity evidence would be needed to use this comparison for equipment sizing. The handoff recovers the fixed outlet boundary and retains the sampled flow demand. It does not advance header or knockout-drum inventory or return pressure to the native transient.