The standard SystemSrkCPAstatoil water parameterization underpredicts liquid isobaric heat capacity by about 8–17% between 5 and 60 °C near atmospheric pressure. Its good density predictions do not establish caloric accuracy. Issue #3762 is a model-calibration limitation: numerical differentiation confirms the legacy getCp() agrees with the legacy enthalpy derivative. The evidence does not establish a missing association derivative.

Enable the calibrated water alpha

SystemSrkCPAstatoil fluid = new SystemSrkCPAstatoil(298.15, 1.01325);
fluid.setUseCaloricWaterAlpha(true);
fluid.addComponent("water", 1.0);
fluid.setMixingRule(10);
new ThermodynamicOperations(fluid).TPflash();
fluid.initProperties();
double cp = fluid.getPhase(0).getCp("J/kgK");
double density = fluid.getPhase(0).getDensity("kg/m3");

The same setter is accessible through the Python/JPype interface. It may be called before or after adding water. Reflash and initialize properties after changing it. setUseCaloricWaterAlpha(false) restores the legacy choice; isUsingCaloricWaterAlpha() reports the selection. The default remains legacy CPA. Following any change to the component list, set the mixing rule again.

The new choice changes the EOS attraction function, so fugacity, enthalpy, entropy, and heat capacities use its analytic derivatives consistently. It does not patch the reported heat capacity. Other components retain their existing attraction functions, including TEG. Water ideal-gas heat capacity, association energy/volume, covolume, and existing physical-property volume correction remain unchanged. Mixtures containing water can nevertheless change because the water attraction participates in the mixing rule.

Equations and provenance

The reduced-temperature polynomial is

\[a(T)=a_0\alpha(T),\qquad \alpha(T)=\left[1+\sum_{j=1}^{5}c_j\left(1-\sqrt{T/T_c}\right)^j\right]^2.\]
Coefficient Value
$c_1$ 0.6670190973128074
$c_2$ -0.25656681951681287
$c_3$ 1.3687767086793399
$c_4$ -3.1891110889699097
$c_5$ 5.218580308820144

These are new NeqSim calibration coefficients, inspired by the flexible-alpha approach of Palma, Queimada and Coutinho (2017). They are not that paper’s parameter set. NeqSim retains its original water $a_0=0.12277$ Pa m⁶/mol², $b=1.4515\times10^{-5}$ m³/mol, association energy 16655 J/mol, association volume 0.0692, four-site 4C scheme, and $T_c=647.3$ K. The five-coefficient polynomial implementation is reused from AttractiveTermMatCop5PRUMR; only its algebra is reused, and the surrounding EOS remains SRK-CPA. Attractive-term selector 23 is used internally.

Both $a’(T)$ and $a’‘(T)$ enter the existing residual Helmholtz derivatives. There is no hard temperature switch and no pressure- or phase-dependent heat-capacity multiplier. Thermodynamic checks include

\[C_p=\left(\frac{\partial H}{\partial T}\right)_{P,n} =T\left(\frac{\partial S}{\partial T}\right)_{P,n}.\]

For mixtures these identities refer to a fixed-composition single phase; an equilibrium two-phase temperature derivative also includes redistribution between phases and need not equal the sum of phase heat capacities.

Calibration and independent validation

Training uses 12 temperatures at 5 °C intervals from 5 to 60 °C, at 1 bar. The objective includes relative liquid heat-capacity and untranslated density errors, plus liquid/vapour fugacity equality at the IAPWS saturation pressure:

\[J=\sum_k\left[\left(\frac{C_{p,k}/C_{p,k}^{\rm ref}-1}{0.02}\right)^2 +\left(\frac{\rho_k/\rho_k^{\rm ref}-1}{0.01}\right)^2 +\left(\frac{\ln(f_k^L/f_k^V)}{0.02}\right)^2\right].\]

These scales are fitting weights, not experimental uncertainties. The density term uses the unshifted EOS volume; production density acceptance separately checks NeqSim’s existing volume-corrected getDensity("kg/m3") path. The fit does not make untranslated density equivalent to the physical-property density.

Production results at 1.01325 bara (compressed/subcooled liquid, not saturated liquid at this pressure) are:

Temperature, °C Legacy Cp Caloric-alpha Cp IAPWS-95 Cp Cp error Density error
5 3509.13 4203.82 4205.04 -0.029% +0.112%
10 3546.42 4195.86 4195.16 +0.017% -0.007%
25 3651.67 4181.82 4181.31 +0.012% -0.192%
40 3746.86 4178.83 4179.41 -0.014% -0.191%
60 3858.79 4186.15 4184.95 +0.029% +0.013%

Cp is in J/(kg K). These temperatures are represented in the training data; the small pressure difference does not make this an independent temperature validation. The recomputed IAPWS-95 values differ slightly from the rounded values originally reported in the issue.

The checked-in CSV contains 49 stable liquid states and four steam states, including temperature holdouts at 7.5, 18, 32, 80, 100, 125, and 150 °C, and pressure holdouts at 10, 50, and 100 bara. The 55 °C points are correctly labelled as training temperatures. Regression gates require liquid Cp error below 2%, and physical density error below 0.5% only between 5 and 60 °C. Separate saturation-pressure tests cover 5–150 °C with a 2% acceptance band.

The independent pure-CPA evaluator also checks 37 states with temperatures excluded from fitting, reaching 150 °C and 100 bar; its maximum Cp error is 0.841%. Tests of the production implementation check Cp/enthalpy/entropy consistency, alpha derivatives, PH/PS closure, cloning, serialization, model selection, pure TEG, single-liquid water/MEG consistency, and preservation of steam Cp relative to the legacy model. Mixture consistency is not an experimental mixture-accuracy validation.

Reproduce the calibration

devtools/generate_water_caloric_alpha_reference.py contains an independent, analytic pure-water 4C CPA evaluator and reads the existing water parameters from COMP.csv. Optional research dependencies are NumPy, SciPy and iapws; they are not NeqSim runtime dependencies.

python devtools/generate_water_caloric_alpha_reference.py --refit --output-dir /tmp/cpa-water-reference
./mvnw -Dtest=CPAWaterCaloricTest,SystemSrkCPAstatoilTest,PHFlashCPATest test

The checked-in src/test/resources/thermo/water_caloric_alpha_fit.json records coefficients, fixed parameters, training data, independent holdouts, objective, optimizer configuration and package versions. The adjacent water_caloric_alpha_iapws95_reference.csv supplies the Java reference tests. Reference values are calculations using iapws.IAPWS95 1.5.5, following IAPWS R6-95(2018). The optional GPLv3 reference package is used as a numerical oracle; its source is not copied or incorporated into the Java implementation.

Literature assessment and limits

Recommended scope: opt-in pure liquid-water caloric calculations within the checked 5–150 °C and 1–100 bara envelope, above the saturation pressure. Density qualification is narrower: 5–60 °C. This is not IAPWS accuracy throughout that rectangle, and the listed checks do not establish a mathematical error bound. At 5 °C and 300 bar the independent evaluator already gives about +2.5% Cp error. Near-critical, supercritical, electrolyte, hydrate and mixture-property accuracy remain unqualified. Steam Cp is preserved, not newly validated to 2% against IAPWS; some pre-existing steam errors remain several percent.

A future water-structure term should be added to the residual Helmholtz energy, with consistent temperature, volume and composition derivatives, and fitted jointly to Cp/Cv, density/expansivity, sound speed, VLE and mixture data. A density-independent water correction applied to every phase would also change ideal-gas/steam caloric properties. A liquid-only Cp override would break the derivative identities used in energy and entropy flashes. The present results do not require either approach for the issue’s operating range.