Example of Completion and Inflow Control Setup
Standard completion with no inflow control devices
Example of Completor setup with no inflow control device, however, the device layer will be printed in the output.
This example is also stating that the schedule
file is defined in the case file as tubing_msw_def.well
.
SCHFILE
--This keyword is optional. To be included if the input schedule file is not called directly from the command line.
--Used for including schedule file containing the tubing ulti-segment well (MSW) definition in terms of
--WELSPECS, COMPDAT, WELSEGS and COMPSEGS.
tubing_msw_def.well
/
COMPLETION
--Well Branch StartMD EndMD Screen Well/ Roughness Annulus Nvalve/Joint ValveType DeviceNumber
-- Number Tubing asing Content
-- Diameter Diameter
OP1 1 0 10000 0.15364 0.1905 1.524E-005 GP 1 PERF 1
OP1 2 0 10000 0.15364 0.1905 1.524E-005 GP 1 PERF 1
/
-- Set GP_PERF_DEVICELAYER to TRUE if a device layer for this type of completion is needed.
GP_PERF_DEVICELAYER
TRUE
/
Completion with AICDs
Example of Completor setup with AICD with a mix of a blank section.
In this example, instead of connecting the second lateral into tubing,
this example will connect the second lateral to the device in the first lateral due to the keyword LATERAL_TO_DEVICE
.
COMPLETION
--Well Branch StartMD EndMD Screen Well/ Roughness Annulus Nvalve/Joint ValveType DeviceNumber
-- Number Tubing Casing Content
-- Diameter Diameter
OP1 1 0 3500 0.15364 0.1905 1.524E-005 GP 0 AICD 1 -- BLANK completion
OP1 1 3500 5000 0.15364 0.1905 1.524E-005 GP 1 AICD 1 -- AICD completion
OP1 1 5000 99999 0.15364 0.1905 1.524E-005 GP 0 AICD 1 -- BLANK completion
OP1 2 0 4000 0.15364 0.1905 1.524E-005 GP 0 AICD 1 -- BLANK completion
OP1 2 4000 5500 0.15364 0.1905 1.524E-005 GP 1 AICD 1 -- AICD completion
OP1 2 5500 99999 0.15364 0.1905 1.524E-005 GP 0 AICD 1 -- BLANK completion
/
LATERAL_TO_DEVICE
-- Branch 2 of OP1 is routed to the device layer in branch 1 and not the tubing layer.
OP1 2
/
WSEGAICD
-- NB: Dummy parameters
--Number Alpha x y a b c d e f rhocal viscal
1 0.000017253 3.05 0.67 1 1 1 2.43 1.18 10.0 1000 1
2 0.000021059 2.94 0.69 1 1 1 1.96 1.22 4.64 1000 1
3 0.000019331 2.98 0.65 1 1 1 2.13 1.27 5.60 1000 1
/
Completion with spiral ICDs
Example with the use of sICD.
COMPLETION
--Well Branch StartMD EndMD Screen Well/ Roughness Annulus Nvalve ValveType DeviceNumber
-- Number Tubing Casing Content /Joint
-- Diameter Diameter
OP1 1 0 10000 0.15364 0.1905 1.524E-005 GP 1 ICD 1
OP1 2 0 10000 0.15364 0.1905 1.524E-005 GP 1 ICD 2
/
WSEGSICD
-- NB: Dummy parameters. Contact the Equinor Inflow Control Team for actual values suitable for your case.
-- DeviceNumber Strength RhoCal VisCal WatFract.
1 1e-4 1000 1 1*
2 2e-4 1000 1 1*
/
Completion with nozzle ICDs
Example the use of Completor to set up a nozzle ICD. The use of nozzle ICD will produce a keyword of WSEGVALV
.
This keyword is widely used on other types of devices in Completor for example ICV
and DAR
.
COMPLETION
--Well Branch StartMD EndMD Screen Well/ Roughness Annulus Nvalve ValveType DeviceNumber
-- Number Tubing Casing Content /Joint
-- Diameter Diameter
OP1 1 0 10000 0.15364 0.1905 1.524E-005 GP 1 VALVE 1
OP1 2 0 10000 0.15364 0.1905 1.524E-005 GP 1 VALVE 2
/
WSEGVALV
-- NB: Dummy parameters.
-- DeviceNumber Cv Ac L
1 1e-2 7.50e-4 1*
2 1e-2 1.56e-4 1*
3 1e-2 1.53e-4 1*
/
Completion with DAR
An example with DAR (Density Activated Recovery).
This keyword will generate sets of WSEGVALV
,
ACTIONX
, and UDQ
.
COMPLETION
--Well Branch StartMD EndMD Screen Well/ Roughness Annulus Nvalve/Joint ValveType DeviceNumber
-- Number Tubing Casing Content
-- Diameter Diameter
OP1 1 0 10000 0.15364 0.1905 1.524E-005 GP 1 DAR 1
OP1 2 0 10000 0.15364 0.1905 1.524E-005 GP 1 DAR 2
/
WSEGDAR
-- NB: Dummy parameters.
-- Number Cv Oil_Ac Gas_Ac Water_Ac wvf_low wvf_high gvf_low gvf_high
1 1.0 7.5e-4 1.56e-4 1.53e-4 0.75 0.80 0.70 0.90
2 1.0 7.5e-4 1.56e-4 1.53e-4 0.50 0.75 0.50 0.80
/
Completion with AICV
This keyword WSEGAICV
will act like WSEGAICD
keyword and acting dependent on the working criteria using ACTIONX
.
COMPLETION
--Well Branch StartMD EndMD Screen Well/ Roughness Annulus Nvalve/Joint ValveType DeviceNumber
-- Number Tubing Casing Content
-- Diameter Diameter
OP1 1 0 10000 0.15364 0.1905 1.524E-005 GP 1 AICV 1
OP1 2 0 10000 0.15364 0.1905 1.524E-005 GP 1 AICV 1
/
WSEGAICV
-- NB: Dummy parameters.
--NUMBER WCT GVF RhoCal VisCal Alp.Main x.Main y.Main aMain b.Main c.Main d.Main e.Main f.Main Alp.Pilot x.Pilot yPilot a.Pilot b.Pilot c.Pilot d.Pilot e.Pilot f.Pilot
1 0.95 0.95 1000 1 7.677e-5 2.99 1.543 1 1 1 0.39 0.64 1 4.98e-5 3.37 1.492 1 1 1 1.8 0.11 1.0
/
Completion with open annulus (no gravel pack and no packer)
This is an example to set up a well completion with open annulus without a packer. It means that this well is completed with open annulus from top to bottom (unrealistic example). Completor will automatically set up a packer at the start and end of a reservoir section.
COMPLETION
--Well Branch StartMD EndMD Screen Well/ Roughness Annulus Nvalve/Joint ValveType DeviceNumber
-- Number Tubing Casing Content
-- Diameter Diameter
OP1 1 0 10000 0.15364 0.1905 1.524E-005 OA 1 AICD 1
OP1 2 0 10000 0.15364 0.1905 1.524E-005 OA 1 AICD 1
/
WSEGAICD
-- NB: Dummy parameters.
--Number Alpha x y a b c d e f rhocal viscal
1 0.000017253 3.05 0.67 1 1 1 243 1.18 10.0 1000 1
2 0.000021059 2.94 0.69 1 1 1 196 1.22 4.64 1000 1
3 0.000019331 2.98 0.65 1 1 1 213 1.27 5.60 1000 1
/
Completion with packers every 300 meters
This is a more realistic example where the completion is set up with open annulus and packer for every 300 meters.
COMPLETION
--Well Branch StartMD EndMD Screen Well/ Roughness Annulus Nvalve/Joint ValveType DeviceNumber
-- Number Tubing Casing Content
-- Diameter Diameter
OP1 1 0 1640 0.15364 0.1905 1.524E-005 OA 1 AICD 1
OP1 1 1640 1640 0.15364 0.1905 1.524E-005 PA 1 AICD 1
OP1 1 1640 1940 0.15364 0.1905 1.524E-005 OA 1 AICD 1
OP1 1 1940 1940 0.15364 0.1905 1.524E-005 PA 1 AICD 1
OP1 1 1940 2240 0.15364 0.1905 1.524E-005 OA 1 AICD 1
OP1 1 2240 2240 0.15364 0.1905 1.524E-005 PA 1 AICD 1
OP1 1 2240 2540 0.15364 0.1905 1.524E-005 OA 1 AICD 1
OP1 1 2540 2540 0.15364 0.1905 1.524E-005 PA 1 AICD 1
OP1 1 2540 2920 0.15364 0.1905 1.524E-005 OA 1 AICD 1
OP1 2 0 1660 0.15364 0.1905 1.524E-005 OA 1 AICD 1
OP1 2 1660 1660 0.15364 0.1905 1.524E-005 PA 1 AICD 1
OP1 2 1660 1960 0.15364 0.1905 1.524E-005 OA 1 AICD 1
OP1 2 1960 1960 0.15364 0.1905 1.524E-005 PA 1 AICD 1
OP1 2 1960 2110 0.15364 0.1905 1.524E-005 OA 1 AICD 1
/
WSEGAICD
-- NB: Dummy parameters.
--Number Alpha x y a b c d e f rhocal viscal
1 0.000017253 3.05 0.67 1 1 1 243 1.18 10.0 1000 1
2 0.000021059 2.94 0.69 1 1 1 196 1.22 4.64 1000 1
3 0.000019331 2.98 0.65 1 1 1 213 1.27 5.60 1000 1
/
Completion with packers every 300 meters and blank pipe until 1640 MD
A more complex combination with including blank pipe in open annulus and packer combination completion.
COMPLETION
--Well Branch StartMD EndMD Screen Well/ Roughness Annulus Nvalve/Joint ValveType DeviceNumber
-- Number Tubing Casing Content
-- Diameter Diameter
OP1 1 1340 1640 0.15364 0.1905 1.524E-005 GP 0 AICD 1
OP1 1 1640 1640 0.15364 0.1905 1.524E-005 PA 1 AICD 1
OP1 1 1640 1940 0.15364 0.1905 1.524E-005 OA 1 AICD 1
OP1 1 1940 1940 0.15364 0.1905 1.524E-005 PA 1 AICD 1
OP1 1 1940 2240 0.15364 0.1905 1.524E-005 OA 1 AICD 1
OP1 1 2240 2240 0.15364 0.1905 1.524E-005 PA 1 AICD 1
OP1 1 2240 2540 0.15364 0.1905 1.524E-005 OA 1 AICD 1
OP1 1 2540 2540 0.15364 0.1905 1.524E-005 PA 1 AICD 1
OP1 1 2540 2920 0.15364 0.1905 1.524E-005 OA 1 AICD 1
OP1 2 1360 1660 0.15364 0.1905 1.524E-005 OA 1 AICD 1
OP1 2 1660 1660 0.15364 0.1905 1.524E-005 PA 1 AICD 1
OP1 2 1660 1960 0.15364 0.1905 1.524E-005 OA 1 AICD 1
OP1 2 1960 1960 0.15364 0.1905 1.524E-005 PA 1 AICD 1
OP1 2 1960 2110 0.15364 0.1905 1.524E-005 OA 1 AICD 1
/
WSEGAICD
-- NB: Dummy parameters.
--Number Alpha x y a b c d e f rhocal viscal
1 0.000017253 3.05 0.67 1 1 1 243 1.18 10.0 1000 1
2 0.000021059 2.94 0.69 1 1 1 196 1.22 4.64 1000 1
3 0.000019331 2.98 0.65 1 1 1 213 1.27 5.60 1000 1
/
Completion with AICDs every second screen joint
COMPLETION
--Well Branch StartMD EndMD Screen Well/ Roughness Annulus Nvalve/Joint ValveType DeviceNumber
-- Number Tubing Casing Content
-- Diameter Diameter
OP1 1 0 10000 0.15364 0.1905 1.524E-005 GP 0.5 AICD 1
OP1 2 0 10000 0.15364 0.1905 1.524E-005 GP 0.5 AICD 1
/
WSEGAICD
-- NB: Dummy parameters.
--Number Alpha x y a b c d e f rhocal viscal
1 0.000017253 3.05 0.67 1 1 1 243 1.18 10.0 1000 1
2 0.000021059 2.94 0.69 1 1 1 196 1.22 4.64 1000 1
3 0.000019331 2.98 0.65 1 1 1 213 1.27 5.60 1000 1
/
Completion with ICVs that are controlling inflow from reservoir and flow inside the tubing
COMPLETION
--Well Branch StartMD EndMD Screen Well/ Roughness Annulus Nvalve/Joint ValveType DeviceNumber
-- Number Tubing Casing Roughness Content
-- Diameter Diameter
OP1 1 0 3000 0.15364 0.1905 1.524E-005 GP 1 ICV 1 -- ICV connected into reservoir flow
OP1 1 3000 3000 0.15364 0.1905 1.524E-005 GP 1 ICV 3 -- ICV controlling flow inside tubing below ICV
OP1 1 3000 10000 0.15364 0.1905 1.524E-005 GP 1 ICV 1 -- ICV connected into reservoir flow
OP1 2 0 4000 0.15364 0.1905 1.524E-005 GP 1 ICV 2 -- ICV connected into reservoir flow
OP1 2 4000 4000 0.15364 0.1905 1.524E-005 GP 1 ICV 3 -- ICV controlling flow inside tubing below ICV
OP1 2 4000 10000 0.15364 0.1905 1.524E-005 GP 1 ICV 2 -- ICV connected into reservoir flow
/
WSEGICV
-- NB: Dummy parameters.
-- DeviceNumber Cv Ac Ac_max
1 0.95 4.32e-4 7.50e-4
2 1.10 1.56e-4 7.50e-4
3 1.00 0.05 0.05
/