v8.13 to v8.14
In this migration guide you will find:
Yaml migration
1. New feature for GENERATORSETS
- Allow additional input related to
POWER_FROM_SHORE
category, in order to report extra output. The following are new optional keywords underGENERATORSETS
:CABLE_LOSS
: Fraction, describing power loss from shore. Used to calculate actual power supply onshore.MAX_USAGE_FROM_SHORE
: The peak load/effect that is expected for one hour, per year (MW).
The new yaml implementation is described below:
GENERATORSETS:
- NAME: <generator set name>
CATEGORY: POWER_FROM_SHORE
FUEL: <optional fuel configuration reference>
ELECTRICITY2FUEL: <electricity to fuel facility input reference>
CABLE_LOSS: <optional expression or value>
MAX_USAGE_FROM_SHORE: <optional expression or value>
CONSUMERS:
...