Class ReactorCapacityStrategy
java.lang.Object
neqsim.process.equipment.capacity.ReactorCapacityStrategy
- All Implemented Interfaces:
EquipmentCapacityStrategy
Capacity strategy for reactor equipment.
This strategy evaluates reactor capacity based on constraints including:
- Heat duty vs design duty
- Conversion vs target conversion
- Residence time vs minimum required
- Temperature limits
- Version:
- 1.0
- Author:
- NeqSim Development Team
-
Field Summary
FieldsModifier and TypeFieldDescriptionstatic final doubleDefault design heat duty in kW.static final doubleDefault maximum reactor temperature in Celsius.private doubleprivate double -
Constructor Summary
ConstructorsConstructorDescriptionDefault constructor.ReactorCapacityStrategy(double maxTemperatureC, double maxDutyKW) Constructor with custom constraints. -
Method Summary
Modifier and TypeMethodDescriptionprivate voidaddCSTRConstraints(Map<String, CapacityConstraint> constraints, StirredTankReactor cstr) Adds constraints specific to stirred tank reactors.private voidaddGibbsConstraints(Map<String, CapacityConstraint> constraints, GibbsReactor gibbs) Adds constraints specific to Gibbs reactors.private voidaddPlugFlowConstraints(Map<String, CapacityConstraint> constraints, PlugFlowReactor pfr) Adds constraints specific to plug flow reactors.doubleevaluateCapacity(ProcessEquipmentInterface equipment) Evaluates the current capacity utilization of the equipment.doubleevaluateMaxCapacity(ProcessEquipmentInterface equipment) Evaluates the maximum capacity of the equipment.getBottleneckConstraint(ProcessEquipmentInterface equipment) Gets the bottleneck constraint (highest utilization).getConstraints(ProcessEquipmentInterface equipment) Gets all capacity constraints for this equipment.Class<? extends ProcessEquipmentInterface> Gets the equipment class this strategy handles.getName()Gets a descriptive name for this strategy.intGets the priority of this strategy.getViolations(ProcessEquipmentInterface equipment) Gets the list of constraint violations for this equipment.booleanisWithinHardLimits(ProcessEquipmentInterface equipment) Checks if the equipment is operating within all hard limits.booleanisWithinSoftLimits(ProcessEquipmentInterface equipment) Checks if the equipment is operating within all soft limits (design values).booleansupports(ProcessEquipmentInterface equipment) Checks if this strategy supports the given equipment.Methods inherited from class Object
clone, equals, finalize, getClass, hashCode, notify, notifyAll, toString, wait, wait, waitMethods inherited from interface EquipmentCapacityStrategy
getAvailableMargin
-
Field Details
-
DEFAULT_MAX_TEMPERATURE_C
public static final double DEFAULT_MAX_TEMPERATURE_CDefault maximum reactor temperature in Celsius.- See Also:
-
DEFAULT_MAX_DUTY_KW
public static final double DEFAULT_MAX_DUTY_KWDefault design heat duty in kW.- See Also:
-
maxTemperatureC
private double maxTemperatureC -
maxDutyKW
private double maxDutyKW
-
-
Constructor Details
-
ReactorCapacityStrategy
public ReactorCapacityStrategy()Default constructor. -
ReactorCapacityStrategy
public ReactorCapacityStrategy(double maxTemperatureC, double maxDutyKW) Constructor with custom constraints.- Parameters:
maxTemperatureC- maximum reactor temperature in CelsiusmaxDutyKW- maximum heat duty in kW
-
-
Method Details
-
supports
Checks if this strategy supports the given equipment.- Specified by:
supportsin interfaceEquipmentCapacityStrategy- Parameters:
equipment- the equipment to check- Returns:
- true if this strategy can evaluate the equipment
-
getPriority
public int getPriority()Gets the priority of this strategy.When multiple strategies support the same equipment, the one with higher priority is used. Default priority is 0. Use positive values for more specific strategies.
- Specified by:
getPriorityin interfaceEquipmentCapacityStrategy- Returns:
- the priority value (higher = more preferred)
-
getName
Gets a descriptive name for this strategy.- Specified by:
getNamein interfaceEquipmentCapacityStrategy- Returns:
- strategy name
-
getEquipmentClass
Gets the equipment class this strategy handles.- Specified by:
getEquipmentClassin interfaceEquipmentCapacityStrategy- Returns:
- the equipment class
-
evaluateCapacity
Evaluates the current capacity utilization of the equipment.Returns a value between 0 and 1+ where:
- 0.0 = no load
- 1.0 = at design capacity
- >1.0 = over capacity
- Specified by:
evaluateCapacityin interfaceEquipmentCapacityStrategy- Parameters:
equipment- the equipment to evaluate- Returns:
- capacity utilization as a fraction
-
evaluateMaxCapacity
Evaluates the maximum capacity of the equipment.Returns the maximum capacity in the equipment's natural units (e.g., flow rate, power, duty).
- Specified by:
evaluateMaxCapacityin interfaceEquipmentCapacityStrategy- Parameters:
equipment- the equipment to evaluate- Returns:
- maximum capacity
-
getConstraints
Gets all capacity constraints for this equipment.Returns a map of constraint name to constraint object. The constraints include both the current value and the design/limit values.
- Specified by:
getConstraintsin interfaceEquipmentCapacityStrategy- Parameters:
equipment- the equipment to get constraints for- Returns:
- map of constraint name to CapacityConstraint
-
addPlugFlowConstraints
private void addPlugFlowConstraints(Map<String, CapacityConstraint> constraints, PlugFlowReactor pfr) Adds constraints specific to plug flow reactors.- Parameters:
constraints- map to add constraints topfr- the plug flow reactor
-
addCSTRConstraints
private void addCSTRConstraints(Map<String, CapacityConstraint> constraints, StirredTankReactor cstr) Adds constraints specific to stirred tank reactors.- Parameters:
constraints- map to add constraints tocstr- the stirred tank reactor
-
addGibbsConstraints
Adds constraints specific to Gibbs reactors.- Parameters:
constraints- map to add constraints togibbs- the Gibbs reactor
-
getViolations
Gets the list of constraint violations for this equipment.Returns only the constraints that are currently violated (utilization > 1.0 or outside limits).
- Specified by:
getViolationsin interfaceEquipmentCapacityStrategy- Parameters:
equipment- the equipment to check- Returns:
- list of violated constraints
-
getBottleneckConstraint
Gets the bottleneck constraint (highest utilization).- Specified by:
getBottleneckConstraintin interfaceEquipmentCapacityStrategy- Parameters:
equipment- the equipment to evaluate- Returns:
- the constraint with highest utilization, or null if none
-
isWithinHardLimits
Checks if the equipment is operating within all hard limits.- Specified by:
isWithinHardLimitsin interfaceEquipmentCapacityStrategy- Parameters:
equipment- the equipment to check- Returns:
- true if no hard limits are violated
-
isWithinSoftLimits
Checks if the equipment is operating within all soft limits (design values).- Specified by:
isWithinSoftLimitsin interfaceEquipmentCapacityStrategy- Parameters:
equipment- the equipment to check- Returns:
- true if no soft limits are violated
-