Class SplitterCapacityStrategy
java.lang.Object
neqsim.process.equipment.capacity.SplitterCapacityStrategy
- All Implemented Interfaces:
EquipmentCapacityStrategy
Capacity strategy for splitter equipment.
This strategy evaluates splitter capacity based on multiple constraints including:
- Header velocity (erosion and pressure drop)
- Pressure drop through distribution
- Flow distribution uniformity
- Branch flow rates
- Version:
- 1.0
- Author:
- NeqSim Development Team
-
Field Summary
FieldsModifier and TypeFieldDescriptionstatic final doubleDefault maximum pressure drop (bar).static final doubleDefault maximum header velocity (m/s).private doubleprivate double -
Constructor Summary
ConstructorsConstructorDescriptionDefault constructor.SplitterCapacityStrategy(double maxVelocity, double maxPressureDrop) Constructor with custom constraints. -
Method Summary
Modifier and TypeMethodDescriptionprivate doubleevaluateBasicCapacity(Splitter splitter) Evaluates basic capacity when splitter doesn't have constraint interface.doubleevaluateCapacity(ProcessEquipmentInterface equipment) Evaluates the current capacity utilization of the equipment.doubleevaluateMaxCapacity(ProcessEquipmentInterface equipment) Evaluates the maximum capacity of the equipment.getBottleneckConstraint(ProcessEquipmentInterface equipment) Gets the bottleneck constraint (highest utilization).getConstraints(ProcessEquipmentInterface equipment) Gets all capacity constraints for this equipment.Class<? extends ProcessEquipmentInterface> Gets the equipment class this strategy handles.doubleGets the maximum pressure drop.doubleGets the maximum velocity.getName()Gets a descriptive name for this strategy.intGets the priority of this strategy.getViolations(ProcessEquipmentInterface equipment) Gets the list of constraint violations for this equipment.booleanisWithinHardLimits(ProcessEquipmentInterface equipment) Checks if the equipment is operating within all hard limits.booleanisWithinSoftLimits(ProcessEquipmentInterface equipment) Checks if the equipment is operating within all soft limits (design values).voidsetMaxPressureDrop(double maxPressureDrop) Sets the maximum pressure drop.voidsetMaxVelocity(double maxVelocity) Sets the maximum velocity.booleansupports(ProcessEquipmentInterface equipment) Checks if this strategy supports the given equipment.Methods inherited from class Object
clone, equals, finalize, getClass, hashCode, notify, notifyAll, toString, wait, wait, waitMethods inherited from interface EquipmentCapacityStrategy
getAvailableMargin
-
Field Details
-
DEFAULT_MAX_VELOCITY
public static final double DEFAULT_MAX_VELOCITYDefault maximum header velocity (m/s).- See Also:
-
DEFAULT_MAX_PRESSURE_DROP
public static final double DEFAULT_MAX_PRESSURE_DROPDefault maximum pressure drop (bar).- See Also:
-
maxVelocity
private double maxVelocity -
maxPressureDrop
private double maxPressureDrop
-
-
Constructor Details
-
SplitterCapacityStrategy
public SplitterCapacityStrategy()Default constructor. -
SplitterCapacityStrategy
public SplitterCapacityStrategy(double maxVelocity, double maxPressureDrop) Constructor with custom constraints.- Parameters:
maxVelocity- maximum header velocity (m/s)maxPressureDrop- maximum pressure drop (bar)
-
-
Method Details
-
supports
Checks if this strategy supports the given equipment.- Specified by:
supportsin interfaceEquipmentCapacityStrategy- Parameters:
equipment- the equipment to check- Returns:
- true if this strategy can evaluate the equipment
-
getPriority
public int getPriority()Gets the priority of this strategy.When multiple strategies support the same equipment, the one with higher priority is used. Default priority is 0. Use positive values for more specific strategies.
- Specified by:
getPriorityin interfaceEquipmentCapacityStrategy- Returns:
- the priority value (higher = more preferred)
-
getName
Gets a descriptive name for this strategy.- Specified by:
getNamein interfaceEquipmentCapacityStrategy- Returns:
- strategy name
-
getEquipmentClass
Gets the equipment class this strategy handles.- Specified by:
getEquipmentClassin interfaceEquipmentCapacityStrategy- Returns:
- the equipment class
-
evaluateCapacity
Evaluates the current capacity utilization of the equipment.Returns a value between 0 and 1+ where:
- 0.0 = no load
- 1.0 = at design capacity
- >1.0 = over capacity
- Specified by:
evaluateCapacityin interfaceEquipmentCapacityStrategy- Parameters:
equipment- the equipment to evaluate- Returns:
- capacity utilization as a fraction
-
evaluateBasicCapacity
Evaluates basic capacity when splitter doesn't have constraint interface.- Parameters:
splitter- the splitter to evaluate- Returns:
- utilization factor (0-1+)
-
evaluateMaxCapacity
Evaluates the maximum capacity of the equipment.Returns the maximum capacity in the equipment's natural units (e.g., flow rate, power, duty).
- Specified by:
evaluateMaxCapacityin interfaceEquipmentCapacityStrategy- Parameters:
equipment- the equipment to evaluate- Returns:
- maximum capacity
-
getConstraints
Gets all capacity constraints for this equipment.Returns a map of constraint name to constraint object. The constraints include both the current value and the design/limit values.
- Specified by:
getConstraintsin interfaceEquipmentCapacityStrategy- Parameters:
equipment- the equipment to get constraints for- Returns:
- map of constraint name to CapacityConstraint
-
getViolations
Gets the list of constraint violations for this equipment.Returns only the constraints that are currently violated (utilization > 1.0 or outside limits).
- Specified by:
getViolationsin interfaceEquipmentCapacityStrategy- Parameters:
equipment- the equipment to check- Returns:
- list of violated constraints
-
getBottleneckConstraint
Gets the bottleneck constraint (highest utilization).- Specified by:
getBottleneckConstraintin interfaceEquipmentCapacityStrategy- Parameters:
equipment- the equipment to evaluate- Returns:
- the constraint with highest utilization, or null if none
-
isWithinHardLimits
Checks if the equipment is operating within all hard limits.- Specified by:
isWithinHardLimitsin interfaceEquipmentCapacityStrategy- Parameters:
equipment- the equipment to check- Returns:
- true if no hard limits are violated
-
isWithinSoftLimits
Checks if the equipment is operating within all soft limits (design values).- Specified by:
isWithinSoftLimitsin interfaceEquipmentCapacityStrategy- Parameters:
equipment- the equipment to check- Returns:
- true if no soft limits are violated
-
setMaxVelocity
public void setMaxVelocity(double maxVelocity) Sets the maximum velocity.- Parameters:
maxVelocity- maximum velocity in m/s
-
getMaxVelocity
public double getMaxVelocity()Gets the maximum velocity.- Returns:
- maximum velocity in m/s
-
setMaxPressureDrop
public void setMaxPressureDrop(double maxPressureDrop) Sets the maximum pressure drop.- Parameters:
maxPressureDrop- maximum pressure drop in bar
-
getMaxPressureDrop
public double getMaxPressureDrop()Gets the maximum pressure drop.- Returns:
- maximum pressure drop in bar
-