Uses of Class
neqsim.process.equipment.splitter.Splitter
Packages that use Splitter
Package
Description
-
Uses of Splitter in neqsim.process.calibration
Fields in neqsim.process.calibration declared as Splitter -
Uses of Splitter in neqsim.process.equipment.distillation
Fields in neqsim.process.equipment.distillation declared as Splitter -
Uses of Splitter in neqsim.process.equipment.manifold
Fields in neqsim.process.equipment.manifold declared as Splitter -
Uses of Splitter in neqsim.process.logic.action
Fields in neqsim.process.logic.action declared as SplitterConstructors in neqsim.process.logic.action with parameters of type SplitterModifierConstructorDescriptionSetSplitterAction(Splitter splitter, double[] splitFactors) Creates a set splitter action. -
Uses of Splitter in neqsim.process.util.example
Fields in neqsim.process.util.example declared as SplitterModifier and TypeFieldDescriptionprivate static SplitterIntegratedSafetySystemWithLogicExample.gasSplitterMethods in neqsim.process.util.example with parameters of type SplitterModifier and TypeMethodDescriptionprivate static voidIntegratedSafetySystemExample.resetSystem(ThrottlingValve hippsValve, ThrottlingValve esdInletValve, Splitter gasSplitter, BlowdownValve bdValve, Separator separator, IntegratedSafetySystemExample.HIPPSController hippsController, IntegratedSafetySystemExample.ESDController esdController, PushButton esdButton) Reset system to normal operation.private static voidIntegratedSafetySystemExample.runScenario1_NormalOperation(Stream highPressureFeed, ThrottlingValve hippsValve, ThrottlingValve esdInletValve, Stream separatorInlet, Separator separator, Stream separatorGasOut, Splitter gasSplitter, Stream processStream, Stream blowdownStream, BlowdownValve bdValve, SafetyValve psv, Stream psvOutlet, Mixer flareHeader, Stream flareHeaderOutlet, Flare flare, PressureTransmitter hippsPT1, PressureTransmitter hippsPT2, PressureTransmitter separatorPT, TemperatureTransmitter separatorTT, IntegratedSafetySystemExample.HIPPSController hippsController, IntegratedSafetySystemExample.ESDController esdController, IntegratedSafetySystemExample.FireDetectionSystem fireSystem) Scenario 1: Normal operation with monitoring.private static voidIntegratedSafetySystemExample.runScenario2_HIPPSActivation(Stream highPressureFeed, ThrottlingValve hippsValve, ThrottlingValve esdInletValve, Stream separatorInlet, Separator separator, Stream separatorGasOut, Splitter gasSplitter, Stream processStream, Stream blowdownStream, BlowdownValve bdValve, SafetyValve psv, Stream psvOutlet, Mixer flareHeader, Stream flareHeaderOutlet, Flare flare, PressureTransmitter hippsPT1, PressureTransmitter hippsPT2, PressureTransmitter separatorPT, TemperatureTransmitter separatorTT, IntegratedSafetySystemExample.HIPPSController hippsController, IntegratedSafetySystemExample.ESDController esdController, IntegratedSafetySystemExample.FireDetectionSystem fireSystem) Scenario 2: HIPPS activation due to high pressure.private static voidIntegratedSafetySystemExample.runScenario3_ESDAndBlowdown(Stream highPressureFeed, ThrottlingValve hippsValve, ThrottlingValve esdInletValve, Stream separatorInlet, Separator separator, Stream separatorGasOut, Splitter gasSplitter, Stream processStream, Stream blowdownStream, BlowdownValve bdValve, SafetyValve psv, Stream psvOutlet, Mixer flareHeader, Stream flareHeaderOutlet, Flare flare, PressureTransmitter hippsPT1, PressureTransmitter hippsPT2, PressureTransmitter separatorPT, TemperatureTransmitter separatorTT, IntegratedSafetySystemExample.HIPPSController hippsController, IntegratedSafetySystemExample.ESDController esdController, IntegratedSafetySystemExample.FireDetectionSystem fireSystem, PushButton esdButton) Scenario 3: ESD activation and blowdown.private static voidIntegratedSafetySystemExample.runScenario4_PSVRelief(Stream highPressureFeed, ThrottlingValve hippsValve, ThrottlingValve esdInletValve, Stream separatorInlet, Separator separator, Stream separatorGasOut, Splitter gasSplitter, Stream processStream, Stream blowdownStream, BlowdownValve bdValve, SafetyValve psv, Stream psvOutlet, Mixer flareHeader, Stream flareHeaderOutlet, Flare flare, PressureTransmitter hippsPT1, PressureTransmitter hippsPT2, PressureTransmitter separatorPT, TemperatureTransmitter separatorTT, IntegratedSafetySystemExample.HIPPSController hippsController, IntegratedSafetySystemExample.ESDController esdController, IntegratedSafetySystemExample.FireDetectionSystem fireSystem) Scenario 4: PSV relief (final protection layer).private static voidIntegratedSafetySystemExample.runSystem(Stream highPressureFeed, ThrottlingValve hippsValve, ThrottlingValve esdInletValve, Stream separatorInlet, Separator separator, Stream separatorGasOut, Splitter gasSplitter, Stream processStream, Stream blowdownStream, BlowdownValve bdValve, SafetyValve psv, Stream psvOutlet, Mixer flareHeader, Stream flareHeaderOutlet, Flare flare) Run all equipment in the system. -
Uses of Splitter in neqsim.process.util.monitor
Constructors in neqsim.process.util.monitor with parameters of type SplitterModifierConstructorDescriptionSplitterResponse(Splitter splitter) Create a response based on aSplitter.