Result container for PSV sizing calculations.
- Author:
- ESOL
-
Field Summary
FieldsModifier and TypeFieldDescriptionprivate final doubleprivate final doubleprivate final doubleprivate final doubleprivate final doubleprivate final doubleprivate final Stringprivate final doubleprivate final doubleprivate final doubleprivate final double -
Constructor Summary
ConstructorsConstructorDescriptionPSVSizingResult(double requiredArea, double requiredAreaIn2, double massFlowCapacity, String recommendedOrifice, double selectedArea, double selectedAreaIn2, double overpressureFraction, double backPressureFraction, double kd, double kb, double kc) Creates a PSV sizing result. -
Method Summary
Modifier and TypeMethodDescriptiondoubledoubledoubledoubledoubledoubledoubledoubledoubledouble
-
Field Details
-
requiredArea
private final double requiredArea -
requiredAreaIn2
private final double requiredAreaIn2 -
massFlowCapacity
private final double massFlowCapacity -
recommendedOrifice
-
selectedArea
private final double selectedArea -
selectedAreaIn2
private final double selectedAreaIn2 -
overpressureFraction
private final double overpressureFraction -
backPressureFraction
private final double backPressureFraction -
kd
private final double kd -
kb
private final double kb -
kc
private final double kc
-
-
Constructor Details
-
PSVSizingResult
public PSVSizingResult(double requiredArea, double requiredAreaIn2, double massFlowCapacity, String recommendedOrifice, double selectedArea, double selectedAreaIn2, double overpressureFraction, double backPressureFraction, double kd, double kb, double kc) Creates a PSV sizing result.- Parameters:
requiredArea- Required orifice area [m²]requiredAreaIn2- Required orifice area [in²]massFlowCapacity- Mass flow capacity at set pressure [kg/s]recommendedOrifice- Recommended standard orifice letterselectedArea- Selected standard orifice area [m²]selectedAreaIn2- Selected standard orifice area [in²]overpressureFraction- Overpressure fraction (typically 0.1 or 0.21)backPressureFraction- Back pressure / set pressure ratiokd- Discharge coefficientkb- Back pressure correction factorkc- Combination correction factor
-
-
Method Details
-
getRequiredArea
public double getRequiredArea() -
getRequiredAreaIn2
public double getRequiredAreaIn2() -
getMassFlowCapacity
public double getMassFlowCapacity() -
getRecommendedOrifice
-
getSelectedArea
public double getSelectedArea() -
getSelectedAreaIn2
public double getSelectedAreaIn2() -
getOverpressureFraction
public double getOverpressureFraction() -
getBackPressureFraction
public double getBackPressureFraction() -
getDischargeCoefficient
public double getDischargeCoefficient() -
getBackPressureCorrectionFactor
public double getBackPressureCorrectionFactor() -
getCombinationCorrectionFactor
public double getCombinationCorrectionFactor()
-