Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the “Software”), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions:

The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software.

THE SOFTWARE IS PROVIDED “AS IS”, WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.

Functions

GDM_G(SG, Cp_Cv)

Calculate G, the ratio between spesific gravity and Cp/Cv, used in the GDM VOS correction.

GDM_Q(dP, rho, K)

Equation used to calculate the volume flowrate through a device, for example two GDMs.

GDM_SOScorr_dens(rho, tau, c_cal, c_gas[, K])

Speed of sound density correction.

GDM_VOScorr_dens(DT, K3, K4, G, t[, A])

Speed of sound density correction, as given in calibration certificates.

GDM_tempcorr_dens(Du, K18, K19, T[, Tcal])

Density correction for the difference between the operating temperature and the calibration temperature Eq 2-2 in Micro Motion GDM user manual [2].

GDM_uncorr_dens(tau, K0, K1, K2)

Uncorrected density is calculated from instrument time period, described in Eq 2-1 in Micro Motion GDM user manual [1].

gas_spesific_gravity(MW_gas[, MW_air])

Calculate gas spesific gravity as described in eq 2-4 Micro Motion GDM user manual [3].

pvtlib.metering.gas_density_meters.GDM_uncorr_dens(tau, K0, K1, K2)[source]

Uncorrected density is calculated from instrument time period, described in Eq 2-1 in Micro Motion GDM user manual [1].

Parameters:
  • tau (float) – Instrument time period [μs]

  • K0 (float) – GDM calibration factor

  • K1 (float) – GDM calibration factor

  • K2 (float) – GDM calibration factor

Returns:

Du (float) – Measured density from GDM, uncorrected [kg/m3]

References

pvtlib.metering.gas_density_meters.GDM_tempcorr_dens(Du, K18, K19, T, Tcal=20)[source]

Density correction for the difference between the operating temperature and the calibration temperature Eq 2-2 in Micro Motion GDM user manual [2].

Parameters:
  • Du (float) – Measured density from GDM, uncorrected [kg/m3]

  • K18 (float) – GDM calibration factor

  • K19 (float) – GDM calibration factor

  • T (float) – Measured temperature at GDM [C]

  • T_cal (float) – GDM calibration temperature [C]

Returns:

DT (float) – Measured density from GDM, corrected for temperature [kg/m3]

References

pvtlib.metering.gas_density_meters.gas_spesific_gravity(MW_gas, MW_air=28.96469)[source]

Calculate gas spesific gravity as described in eq 2-4 Micro Motion GDM user manual [3].

Parameters:
  • MW_gas (float) – Gas molecular weight [kg/kmol]

  • MW_air (float, optional) – Air molecular weight [kg/kmol]. The default is 28.96469.

Returns:

float – Gas spesific gravity [-]. Returns NaN if MW_air is zero.

References

pvtlib.metering.gas_density_meters.GDM_G(SG, Cp_Cv)[source]

Calculate G, the ratio between spesific gravity and Cp/Cv, used in the GDM VOS correction. Cp/Cv should be calculated at base conditions: 1.01325 barA and 20 C, according to Micro Motion.

Parameters:
  • SG (float) – Gas spesific gravity [-]

  • Cp_Cv (float) – Cp/Cv [-]

Returns:

G (float) – Ratio between SG and Cp/Cv. Returns NaN if Cp_Cv is zero.

References

pvtlib.metering.gas_density_meters.GDM_VOScorr_dens(DT, K3, K4, G, t, A=0.00236)[source]

Speed of sound density correction, as given in calibration certificates. Corresponds to eq 2-3 in Micro Motion GDM user manual [5]. The correction is performed to take into account the difference in properties between the calibration gas and the actual process gas

This method is referred to as the “User Gas Equation Method” in the MicroMotion 7812 manual [6], and is a simplified approach.

Parameters:
  • DT (float) – Measured density from GDM, corrected for temperature [kg/m3]

  • K3 (float) – GDM calibration factor

  • K4 (float) – GDM calibration factor

  • G (float) – Gas spesific gravity / Ratio of spesific heats

  • t (float) – Measured temperature at GDM [C]

Returns:

Dvos (float) – Measured density from GDM, corrected for speed of sound [kg/m3]. Returns NaN if (DT + K4) or (t + 273) is zero.

References

pvtlib.metering.gas_density_meters.GDM_SOScorr_dens(rho, tau, c_cal, c_gas, K=21000.0)[source]

Speed of sound density correction. The correction is performed to take into account the difference in properties between the calibration gas and the actual process gas. The correction factor is given by equation E7 in the Installation and Maintenance Manual for Micro Motion 7812 (P/N MMI-20018377, Rev. AC April 2012) [7]. The equation originates from “Velocity of Sound Effect on Gas Density Transducers - The theory, measurement results and methods of correction”, by Stansfeld, J W (NSFMW 1986) [8]. The same equation is also available in ISO 15970:2014 [9], at a slighly different format.

Parameters:
  • rho (float) – Measured density from GDM, corrected for temperature [kg/m3].

  • tau (float) – Measured instrument time period [μs].

  • c_cal (float) – Speed of sound of calibration gas [m/s] The conditions of this values are not specified in the manual, however, after checking with both Micro Motion and Kiwa, and they both say that they believe the following: The speed of sound of the calibration gas should be given at the same density condition (or time period) as during calibration, according to ISO 15970 [9].

  • c_gas (float) – Speed of sound of measured gas [m/s] at measured conditions (also confirmed by vendor).

  • K (float, optional) – Speed of sound constant for density sensor. The default is 2.1e4 for both the Micro Motion 7812 and the GDM (also confirmed by vendor)

Returns:

rho_vos (float) – Measured density from GDM, corrected for speed of sound [kg/m3]

Notes

There are sometimes confusion about the conditions to be used for the speed of sound of the calibration gas, as this is not explicitly stated in the manual, the ISO, nor the original paper by Stansfeld. But from the derivation of the equation, it can be inferred that the speed of sound should be given at the same conditions as the corresponding density (or time period) during calibration. For example, if a meter (calibrated on nitrogen at 20 °C) measures a gas density (when installed in the process) of 75 kg/m3 (657 μs), the speed of sound of the calibration gas (c_cal) used in the calculation should be the speed of sound of nitrogen at 20 °C and 75 kg/m3, independent of the pressure and temperature of the process gas.

References

pvtlib.metering.gas_density_meters.GDM_Q(dP, rho, K)[source]

Equation used to calculate the volume flowrate through a device, for example two GDMs. According to GDM manual, the flowrate through the GDM should be around 5 l/h, and within 1-10 l/h. A version of the equation is given in the Micro Motion 7812 manual chapter 3.6 [10], with K=0.5.

Parameters:
  • dP (float) – Measured differential pressure accross device. For example dP accross two GDMs [mbar]

  • rho (float) – Measured gas density [kg/m3]

  • K (float) – K-factor. Determined from flow calibration []

Returns:

Q (float) – Volume flowrate through device [l/h]. Returns NaN if rho is zero.

References