Coriolis Pressure Correction¶
This example corrects the accumulated mass of a Coriolis flowmeter for the process-pressure effect, using a calibration run of an Emerson Micro Motion CMF300H at an accredited calibration facility.
Description¶
The notebook shows how to:
Convert the process-pressure effect from the product data sheet (PDS) to the correction factor
PCm, which has the opposite signCorrect the measured accumulated mass with
pvtlib.metering.coriolis_flowmeters.coriolis_massflow_corr_pres()Calculate the error relative to the reference with and without the pressure correction
Equations¶
Mass-flow pressure correction:
Error relative to the reference:
Input Data¶
Parameter |
Value |
|---|---|
Meter |
Emerson Micro Motion CMF300H |
Pressure during the calibration run, |
60 bara |
Factory calibration pressure of the meter, |
2.55 bara |
Reference accumulated mass |
4120.487 kg |
Coriolis accumulated mass (pressure compensation disabled) |
4105.007 kg |
Flow rate during the run |
82 tonnes/h |
Process-pressure effect from the PDS |
-0.006 % of rate per bar |
Correction factor |
+0.006 %/bar |
Usage¶
Open the Jupyter notebook:
jupyter notebook coriolis_pressure_correction_example.ipynb
Required Packages¶
pvtlibpandas
Output¶
The notebook shows a table with the accumulated mass [kg] and the error relative to the reference [%], without and with the pressure correction.