Coriolis Pressure Correction

This example corrects the accumulated mass of a Coriolis flowmeter for the process-pressure effect, using a calibration run of an Emerson Micro Motion CMF300H at an accredited calibration facility.

Description

The notebook shows how to:

  • Convert the process-pressure effect from the product data sheet (PDS) to the correction factor PCm, which has the opposite sign

  • Correct the measured accumulated mass with pvtlib.metering.coriolis_flowmeters.coriolis_massflow_corr_pres()

  • Calculate the error relative to the reference with and without the pressure correction

Equations

Mass-flow pressure correction:

\[m_{corr} = m_{meas}\left(1 + \frac{PCm}{100}(P_{act}-P_{cal})\right)\]

Error relative to the reference:

\[\text{error}~[\%] = 100\cdot\frac{m - m_{ref}}{m_{ref}}\]

Input Data

Parameter

Value

Meter

Emerson Micro Motion CMF300H

Pressure during the calibration run, P_act

60 bara

Factory calibration pressure of the meter, P_cal

2.55 bara

Reference accumulated mass

4120.487 kg

Coriolis accumulated mass (pressure compensation disabled)

4105.007 kg

Flow rate during the run

82 tonnes/h

Process-pressure effect from the PDS

-0.006 % of rate per bar

Correction factor PCm

+0.006 %/bar

Usage

Open the Jupyter notebook:

jupyter notebook coriolis_pressure_correction_example.ipynb

Required Packages

  • pvtlib

  • pandas

Output

The notebook shows a table with the accumulated mass [kg] and the error relative to the reference [%], without and with the pressure correction.