Ultrasonic Meter Wet Gas Over-Reading Correction (Van Putten)

An ultrasonic meter in wet gas reads too high, because the liquid occupies part of the pipe cross section. This example demonstrates the Van Putten over-reading correction, which converts the indicated gas volume flow into the actual gas volume flow.

The notebook plots the over-reading surface, then corrects a single case using both critical gas Froude number variants: from the water-liquid ratio, Equation (27), and from the gas Ohnesorge number, Equations (25)-(26).

All input values in the notebook are illustrative.

Required packages: pvtlib, numpy, pandas, matplotlib

Format: Jupyter Notebook

Reference

van Putten et al., Ultrasonic Meters in Wet Gas Application, North Sea Flow Measurement Workshop, 2015. Paper

The implemented model is the simplified one, Equations (29)-(30). The full physical model, Equation (28), is not implemented.

within_JIP_envelope only confirms that the gas volume fraction, Lockhart-Martinelli parameter, density ratio and gas Froude number are inside the ranges reported from the JIP tests. Meter type, pipe size, installation and fluids still require engineering assessment.