Source code for pvtlib.metering.coriolis_flowmeters
"""MIT License
Copyright (c) 2025 Christian HÃ¥genvik
Permission is hereby granted, free of charge, to any person obtaining a copy
of this software and associated documentation files (the "Software"), to deal
in the Software without restriction, including without limitation the rights
to use, copy, modify, merge, publish, distribute, sublicense, and/or sell
copies of the Software, and to permit persons to whom the Software is
furnished to do so, subject to the following conditions:
The above copyright notice and this permission notice shall be included in all
copies or substantial portions of the Software.
THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE
AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER
LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM,
OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE
SOFTWARE.
"""
[docs]
def coriolis_dens_corr_pres(rho_meas, P_act, PCd, P_cal):
"""Correct Coriolis measured density for pressure effect.
These equations are applicable for Emerson Micro Motion Coriolis flowmeters
using process-pressure-effect values from the ELITE product data sheet (PDS).
They can also be used for other Coriolis meters if the factors are aligned
with the definitions below.
Note that the Micro Motion datasheet provides values for the process-pressure effect on density,
but the correction factor (PCd) has the opposite sign to correct for the effect.
Reference
---------
Emerson: Product Data Sheet - Micro Motion ELITE Coriolis Flow and Density
Meters.
Product Data Sheet
PS-00374, Rev AO
December 2024
https://www.emerson.com/is/content/emerson/en/measurement-instrumentation/
technical/products/flow-coriolis/documents/doc-micro-motion-mmelite-pds-
ps00374an.pdf
Parameters
----------
rho_meas : float
Measured density from Coriolis meter [kg/m3].
P_act : float
Actual process pressure [bara].
PCd : float
Density correction factor [kg/m3/bar].
P_cal : float
Meter calibration pressure [bara].
Returns
-------
float
Density corrected for pressure effect [kg/m3].
"""
return rho_meas + PCd * (P_act - P_cal)
[docs]
def coriolis_massflow_corr_pres(m_meas, P_act, PCm, P_cal):
"""Correct Coriolis measured mass flow for pressure effect.
These equations are applicable for Emerson Micro Motion Coriolis flowmeters
using process-pressure-effect values from the ELITE product data sheet (PDS).
They can also be used for other Coriolis meters if the factors are aligned
with the definitions below. Note that the Micro Motion datasheet provides values for the process-pressure effect on mass flow,
but the correction factor (PCm) has the opposite sign to correct for the effect.
Reference
---------
Emerson: Product Data Sheet - Micro Motion ELITE Coriolis Flow and Density
Meters.
Product Data Sheet
PS-00374, Rev AO
December 2024
https://www.emerson.com/is/content/emerson/en/measurement-instrumentation/
technical/products/flow-coriolis/documents/doc-micro-motion-mmelite-pds-
ps00374an.pdf
Parameters
----------
m_meas : float
Measured mass flow from Coriolis meter [kg/h].
P_act : float
Actual process pressure [bara].
PCm : float
Mass-flow correction factor [%/bar].
P_cal : float
Meter calibration pressure [bara].
Returns
-------
float
Mass flow corrected for pressure effect [kg/h].
"""
return m_meas * (1 + (PCm / 100) * (P_act - P_cal))
[docs]
def coriolis_massflow_cut_off(m_meas, cut_off):
"""Apply a mass-flow cut-off to measured Coriolis flow [kg/h]."""
if m_meas > cut_off:
return m_meas
return 0.0