UPSTREAM_PRESSURE_CONTROL
MODELS / [...] / INTERSTAGE_CONTROL_PRESSURE / UPSTREAM_PRESSURE_CONTROL
Description
This keyword is used only for VARIABLE_SPEED_COMPRESSOR_TRAIN_MULTIPLE_STREAMS_AND_PRESSURES
type. It is used within the INTERSTAGE_CONTROL_PRESSURE keyword.
The pressure control method upstream (before) the interstage pressure is specified in this keyword. For more explanation see Variable speed compressor train model with multiple streams and pressures.
Format
MODELS:
- NAME: <compressor model name>
TYPE: VARIABLE_SPEED_COMPRESSOR_TRAIN_MULTIPLE_STREAMS_AND_PRESSURES
...
STAGES:
...
INTERSTAGE_CONTROL_PRESSURE:
UPSTREAM_PRESSURE_CONTROL: <DOWNSTREAM_CHOKE / UPSTREAM_CHOKE / INDIVIDUAL_ASV_RATE>
...
Example
MODELS:
- NAME: compressor_model
TYPE: VARIABLE_SPEED_COMPRESSOR_TRAIN_MULTIPLE_STREAMS_AND_PRESSURES
...
STAGES:
...
INTERSTAGE_CONTROL_PRESSURE:
UPSTREAM_PRESSURE_CONTROL: UPSTREAM_CHOKE
DOWNSTREAM_PRESSURE_CONTROL: INDIVIDUAL_ASV_RATE